Aligned with achieving the goal of net-zero buildings, the implementation of energy-saving techniques in minimizing energy demands is proving more vital than at any time. As practical and economic options, passive strategies in ventilation developed over thousands of years have shown great potential for the reduction of residential energy demands, which are often underestimated in modern building’s construction. In particular, as a cost-effective passive strategy, wind-driven ventilation via windows has huge potential in the enhancement of the indoor air quality (IAQ) of buildings while simultaneously reducing their cooling load. This study aims to investigate the functionality and applicability of a common historical Turkish architectural element called “Cumba” to improve the wind-driven ventilation in modern buildings. A case study building with an archetypal plan and parameters was defined as a result of a survey over 111 existing traditional samples across Turkey. Buildings with and without Cumba were compared in different scenarios by the development of a validated CFD microclimate model. The results of simulations clearly demonstrate that Cumba can enhance the room’s ventilation rate by more than two times while harvesting wind from different directions. It was also found that a flexible window opening strategy can help to increase the mean ventilation rate by 276%. Moreover, the room’s mean air velocity and ventilation rate could be adjusted to a broad range of values with the existence of Cumba. Thus, this study presents important findings about the importance of plan typology in the effectiveness of wind-driven ventilation strategies in modern dwellings.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Ai ZT, Mak CM (2014). A study of interunit dispersion around multistory buildings with single-sided ventilation under different wind directions. Atmospheric Environment, 88: 1–13.

    Article  Google Scholar 

  • Allocca C, Chen Q, Glicksman LR (2003). Design analysis of singlesided natural ventilation. Energy and Buildings, 35: 785–795.

    Article  Google Scholar 

  • Arseven C (1983). Sanat Ansiklopedisi. Istanbul: Milli egitim bakanlıgı.

    Google Scholar 

  • Bangalee MZI, Lin SY, Miau JJ (2012). Wind driven natural ventilation through multiple windows of a building: A computational approach. Energy and Buildings, 45: 317–325.

    Article  Google Scholar 

  • Blocken B, van Hooff T, Aanen L, Bronsema B (2011). Computational analysis of the performance of a venturi-shaped roof for natural ventilation: Venturi-effect versus wind-blocking effect. Computers and Fluids, 48: 202–213.

    Article  MATH  Google Scholar 

  • Cantin R, Burgholzer J, Guarracino G, Moujalled B, Tamelikecht S, Royet BG (2010). Field assessment of thermal behaviour of historical dwellings in France. Building and Environment, 45: 473–484.

    Article  Google Scholar 

  • Chu C-R, Chiang B-F (2014). Wind-driven cross ventilation in long buildings. Building and Environment, 80: 150–158.

    Article  Google Scholar 

  • Chu C-R, Chiu Y-H, Tsai Y-T, Wu S-L (2015). Wind-driven natural ventilation for buildings with two openings on the same external wall. Energy and Buildings, 108: 365–372.

    Article  Google Scholar 

  • Chu C-R, Chiang B-F (2013). Wind-driven cross ventilation with internal obstacles. Energy and Buildings, 67: 201–209.

    Article  Google Scholar 

  • Dili AS, Naseer MA, Zacharia Varghese T (2011). Passive control methods for a comfortable indoor environment: Comparative investigation of traditional and modern architecture of Kerala in summer. Energy and Buildings, 43: 653–664.

    Article  Google Scholar 

  • Eldem SH (1986). Turkish Houses Ottoman Period. Turkey: Türkiye anıt cevre turizm değerlerini koruma vakfı (T.A.C).

    Google Scholar 

  • Evola G, Popov V (2006). Computational analysis of wind driven natural ventilation in buildings. Energy and Buildings, 38: 491–501.

    Article  Google Scholar 

  • Gebremedhin KG, Wu BX (2003). Characterization of flow field in a ventilated space and simulation of heat exchange between cows and their environment. Journal of Thermal Biology, 28: 301–319.

    Article  Google Scholar 

  • Günay R (1998). Türk ev gelenegi ve Safranbolu evleri. Istanbul: Yapı endüstri merkezi (YEM).

    Google Scholar 

  • Haghighat F, Mirzaei PA (2011). Impact of non-uniform urban surface temperature on pollution dispersion in urban areas. Building Simulation, 4: 227–244.

    Article  Google Scholar 

  • Harriman LG, Lstiburek JW (2009). The ASHRAE Guide for Buildings in Hot and Hummid Climates, 2dn edn. Atlanta: American Society of Heating, Refrigerating, and Air-Conditioning Engineers.

    Google Scholar 

  • Heiselberg P, Svidt K, Nielsen PV (2001). Characteristics of airflow from open windows. Building and Environment, 36: 859–869.

    Article  Google Scholar 

  • Horan JM, Finn DP (2008). Sensitivity of air change rates in a naturally ventilated atrium space subject to variations in external wind speed and direction. Energy and Buildings, 40: 1577–1585.

    Article  Google Scholar 

  • Hu CH, Ohba M, Yoshie R (2008). CFD modelling of unsteady cross ventilation flows using LES. Journal of Wind Engineering and Industrial Aerodynamics, 96: 1692–1706.

    Article  Google Scholar 

  • IPPC/CC (2014). Climate Change 2014 Synthesis report Summary for polcymakes Report of the Intergovermental Panel on Climate Change.

    Google Scholar 

  • IUG-MI (2016). Istanbul universitesi fen fakultesi, astronomi ve uzay bilimleri bolumu. Istanbul universitesi gozlemevi metroroloji istasyonu. Available at http://astronomi.istanbul.edu.tr/meteor.

    Google Scholar 

  • Jiang Y, Alexander D, Jenkins H, Arthur R, Chen Q (2003). Natural ventilation in buildings: Measurement in a wind tunnel and numerical simulation with large-eddy simulation, 91: 331–353.

    Google Scholar 

  • Jiang Y, Allocca C, Chen Q (2004). Validation of CFD simulations for natural ventilation. International Journal of Ventilation, 2: 359–370.

    Article  Google Scholar 

  • Karava P, Stathopoulos T, Athienitis AK (2011). Airflow assessment in cross-ventilated buildings with operable facade elements. Building and Environment, 46: 266–279.

    Article  Google Scholar 

  • Kindangen JI (1997). Window and roof configurations for comfort ventilation. Building Research & Information, 25: 218–225.

    Article  Google Scholar 

  • Kindangen J, Krauss G, Depecker P (1997). Effects of roof shapes on wind-induced air motion inside buildings. Building and Environment, 32: 1–11.

    Article  Google Scholar 

  • Kobayashi T, Chikamoto T, Osada K (2013). Evaluation of ventilation performance of monitor roof in residential area based on simplified estimation and CFD analysis. Building and Environment, 63: 20–30.

    Article  Google Scholar 

  • Kobayashi T, Sandberg M, Kotani H, Claesson L (2010). Experimental investigation and CFD analysis of cross-ventilated flow through single room detached house model. Building and Environment, 45: 2723–2734.

    Article  Google Scholar 

  • Küçükerman Ö (2007). Turkish House in Search of Spatial Identity, 6th edn. Turkey: Türkiye Turing ve Otomobil Kurumu.

    Google Scholar 

  • Lai HK, Kendall M, Ferrier H, Lindup I, Alm S, et al. (2004). Personal exposures and microenvironment concentrations of PM2.5, VOC, NO2 and CO in Oxford, UK. Atmospheric Environment, 38: 6399–6410.

    Article  Google Scholar 

  • McQuiston FC, Parker JD, Spitler JD (2005). Heating, Ventilating and Air Conditioning Analysis and Design, 6th edn. New York: John Wiley & Sons.

    Google Scholar 

  • Mirzaei PA (2015). Recent challenges in modeling of urban heat island. Sustainable Cities and Society, 19: 200–206.

    Article  Google Scholar 

  • Mirzaei PA, Carmeliet J (2013). Dynamical computational fluid dynamics modeling of the stochastic wind for application of urban studies. Building and Environment, 70: 161–170.

    Article  Google Scholar 

  • Mirzaei PA, Haghighat F (2010a). A novel approach to enhance outdoor air quality: Pedestrian ventilation system. Building and Environment, 45: 1582–1593.

    Article  Google Scholar 

  • Mirzaei PA, Haghighat F (2010b). Approaches to study Urban Heat Island—Abilities and limitations. Building and Environment, 45: 2192–2201.

    Article  Google Scholar 

  • Mochida A, Yoshino H, Miyauchi S, Mitamura T (2006). Total analysis of cooling effects of cross-ventilation affected by microclimate around a building. Solar Energy, 80: 371–382.

    Article  Google Scholar 

  • NASA/GCC (2016). NASA Global Climate Change Cital Signs of the Planet. NASA/GCC. Available at http://climate.nasa.gov/vitalsigns/global-temperature.

    Google Scholar 

  • NF (2016). Naturalfrequency—ECOTECT. Available at http://wiki.naturalfrequency.com/wiki/Air_Movement.

    Google Scholar 

  • Norton T, Grant J, Fallon R, Sun DW (2009). Assessing the ventilation effectiveness of naturally ventilated livestock buildings under wind dominated conditions using computational fluid dynamics. Biosystems Engineering, 103: 78–99.

    Article  Google Scholar 

  • Perén JI, van Hooff T, Leite BCC, Blocken B (2015a). CFD analysis of cross-ventilation of a generic isolated building with asymmetric opening positions: Impact of roof angle and opening location. Building and Environment, 85: 263–276.

    Article  Google Scholar 

  • Perén JI, van Hooff T, Leite BCC, Blocken B (2015b). Impact of eaves on cross-ventilation of a generic isolated leeward sawtooth roof building: Windward eaves, leeward eaves and eaves inclination. Building and Environment, 92: 578–590.

    Article  Google Scholar 

  • Perén JI, van Hooff T, Ramponi R, Blocken B, Leite BCC (2015c). Impact of roof geometry of an isolated leeward sawtooth roof building on cross-ventilation: Straight, concave, hybrid or convex? Journal of Wind Engineering and Industrial Aerodynamics, 145: 102–114.

    Article  Google Scholar 

  • Ramponi R, Blocken B (2012). CFD simulation of cross-ventilation for a generic isolated building: Impact of computational parameters. Building and Environment, 53: 34–48.

    Article  Google Scholar 

  • Saadatian O, Haw LC, Sopian K, Sulaiman MY (2012). Review of windcatcher technologies. Renewable and Sustainable Energy Reviews, 16: 1477–1495.

    Article  Google Scholar 

  • Samuel DGL, Nagendra, SMS, Maiya MP (2013). Passive alternatives to mechanical air conditioning of building: A review. Building and Environment, 66: 54–64.

    Article  Google Scholar 

  • Talya H (2007). Gelenksel Turk mimarisinde yapı sistem ve elemanları. Istanbul: urkiye Anıt Cevre Turizm Degerlerini Koruma Vakfı (TAC).

    Google Scholar 

  • Teppner R, Langensteiner B, Meile W, Brenn G, Kerschbaumer S (2014). Air change rates driven by the flow around and through a building storey with fully open or tilted windows: An experimental and numerical study. Energy and Buildings, 76: 640–653.

    Article  Google Scholar 

  • Tominaga Y, Mochida A, Yoshie R, Kataoka H, Nozu T, Yoshikawa M, Shirasawa T (2008). AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings. Journal of Wind Engineering and Industrial Aerodynamics, 96: 1749–1761.

    Article  Google Scholar 

  • Torfs R, Brouwere KD, Spruyt M, Goelen E, Nickmilder M, Bernard A (2008). Exposure and risk assessment of air fresheners. VITO, Document No 2008/IMS/R/222.

    Google Scholar 

  • Vardoulakis S, Dimitroulopoulou C, Thornes J, Lai K-M, Taylor J, et al. (2015). Impact of climate change on the domestic indoor environment and associated health risks in the UK. Environment International, 85: 299–313.

    Article  Google Scholar 

  • WB (2015). Weatherbase. Available at http://www.weatherbase.com.

    Google Scholar 

  • WEC/WERS (2013). World Energy Council World Energy Resources 2013 Survey Summary. London.

    Google Scholar 

  • WEC/WES-2050 (2013). World Energy Council World Energy Scenarios Composing Energy Futures to 2050. London.

    Google Scholar 

  • Wilhelmi OV, Purvis KL, Harriss RC (2004). Designing a Geospatial Information Infrastructure for Mitigation of Heat Wave Hazards in Urban Areas. Natural Hazards Review, 5: 147–158.

    Article  Google Scholar 

Download references

Acknowledgements

The authors would like to express their gratitude to the University of Nottingham for use of their facilities, and Mehmet Aydin for his financial support.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Parham A. Mirzaei.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Aydin, Y.C., Mirzaei, P.A. Wind-driven ventilation improvement with plan typology alteration: A CFD case study of traditional Turkish architecture. Build. Simul. 10, 239–254 (2017). https://doi.org/10.1007/s12273-016-0321-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-016-0321-4

Keywords

Navigation