Skip to main content
Log in

Air and air contaminant flows in office cubicles with and without personal ventilation: A CFD modeling and simulation study

  • Research Article
  • Indoor/Outdoor Airflow and Air Quality
  • Published:
Building Simulation Aims and scope Submit manuscript

Abstract

The paper is aimed at building an appropriate computational fluid dynamics (CFD) model for simulating the flow field in the office cubicle with and without personalized ventilation (PV) and using it to investigate the flow field in the cubicle. A computational model was first constructed by using a commercial CFD code (STAR-CCM). In this process, different approaches to represent manikins, boundary conditions, geometries, and gridding were tested, and a proper approach was selected for simulating the air and contaminant movement in the cubicles and their interactions with the remaining room space. A comparison between the simulation and the experimental results are made to show how accurate the CFD model can be. A brief evaluation of the environmental quality was conducted for both cases with PV and underfloor air diffuser (UFAD). This comparison showed a significant advantage in the PV system, indicating how the PV system performed under different airflow rates. This verified CFD model will be utilized in the future to investigate the performance of the partitioned cubicle collaborating with personalized ventilation systems.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Cermak R, Melikov AK, Foreijt L, Kovar O (2011). Performance of personalized ventilation in conjunction with mixing and displacement ventilation. HVAC&R Research, 12: 295–311.

    Article  Google Scholar 

  • Chen Q, Xu W (1998). A zero-equation turbulence model for indoor air flow simulation. Energy and Building, 28: 137–144.

    Article  Google Scholar 

  • Chludzinska M, Bogdan A (2008). Individual ventilation—Users’ whim or economically justified energy saving. Cieplownictwo, Ogrzewnictwo, Wentylacja, 2: 32–34 (in Polish).

    Google Scholar 

  • Dang T (2008). Personalized ventilation system using combined jet nozzle and flow suction. US Provisional Patent No. 61/022956.

  • Deevy M, Sinai Y, Everitt P, Voigt L, Gobeau N (2008). Modelling the effect of an occupant on displacement ventilation with computional fluid dynamics. Energy and Buildings, 40: 255–264.

    Article  Google Scholar 

  • Dygert RK, Dang TQ (2012). Experimental validation of local exhaust strategies for improved IAQ in aircradt cabins. Building and Environment, 47: 76–88.

    Article  Google Scholar 

  • Dygert RK, Russo JS (2009). Modeling of the human body to study the personal micro environment. ASHRAE Transactions, 115(2): 407–420.

    Google Scholar 

  • Gao N, Niu J (2004). CFD study on mocro-environment around human body and personalized ventilation. Building and Environment, 39: 795–805.

    Article  Google Scholar 

  • Gao N, Niu J (2005). Modeling the performance of personalized ventilation under different room airflows. In: Proceedings of IBPSA International Conference, Montreal, Canada.

    Google Scholar 

  • Gao N, Niu J (2006). Transient CFD simulation of the respiration process and interperson exposure assessment. Building and Environment, 41: 1214–1222.

    Article  Google Scholar 

  • Hayashi T, Ishizu Y, Kato S, Murakami S (2002). CFD analysis on characteristics of contaminated indoor air ventilation and its application in the evaluation of the effects of contaminant inhalation by a human occupant. Building and Environment, 37: 219–230.

    Article  Google Scholar 

  • Houdas Y, Ring E (1982). Human Body Temperature: Its Measurement and Regulation. New York: Plenum Press.

    Book  Google Scholar 

  • ISO 14505-2. (2006). Ergonomics of the thermal environment—Evaluation of the thermal environments in vehicles—Part 2: Determination of equivalent temperature. ISO Standard.

  • Kaczmarczyk J, Melikov AK, Fanger PO (2004). Human response to personalized ventilation and mixing ventilation. Indoor Air, 14(suppl 8): 17–29.

    Article  Google Scholar 

  • Khalifa EH, Janos MI, Dannenhoffer JF (2009). Experimental investigation of reduced-mixing personal ventilation jets. Building and Environment, 44: 1551–1558.

    Article  Google Scholar 

  • Khalifa EH, Prescod SJ, Dannenhoffer JF, Elhadidi B (2006). Computation of occupant exposure in an office cubicle. In: Proceedings of AWMA/EPA Conference: Indoor Air Quality—Problems, Research and Solutions, Durham, USA.

    Google Scholar 

  • Melikov AK (2004). Improving comfort and health by personalized ventilation. In: Proceedings of Roomvent 2004, Coimbra, Portugal.

    Google Scholar 

  • Melikov AK, Cermak R, Majer M (2002). Personalized ventilation: Evaluation of different air terminal devices. Energy and Building, 34: 829–836.

    Article  Google Scholar 

  • Melikov AK, Dzhartov V (2013). Advanced air distribution for minimizing airborne cross-infection in aircradt cabin. HVAC&R Research, 19: 926–933.

    Article  Google Scholar 

  • Nielsen PV, Barszcz E, Czarnota T, Dymalski DP, Jasienski MA, Nowotka A, Nowotka A, Mozer A, Wiankowska SM, Jensen RL (2008). The influence of draught on a seat with integrated personalized ventilation. In: Proceedings of Indoor Air 2008, 11th International Conference in Indoor Air Quality and Climate, Copenhagen, Denmark.

    Google Scholar 

  • Nielsen PV, Bartholomaeussen NM, Jakubowska E, Jiang H, Jonsson OT, Krawiecka K, Mierzejewski A, Jessica SJ, Trampczynska K, Polak M, Soennichsen M (2007a). Chair with integrated personalized ventilation for minimizing cross infection. In: Proceedings of Roomvent 2007, 10th International Conference on Air Distribution in Rooms, Helsinki, Finland.

    Google Scholar 

  • Nielsen PV, Damsgaard C, Liu L, Jensen RL (2013). Test of different air distribution concepts for a single-aisle aircraft cabin. In: Proceedings of CLIMA 2013, Prague, Czech Republic.

    Google Scholar 

  • Nielsen PV, Hyldgard CE, Melikov A, Andersen H, Soennichsen M (2007b). Personal exposure between people in a room ventilated by texile terminals: with and without personalized ventilation. HVAC&R Research, 13: 635–644.

    Article  Google Scholar 

  • Nielsen PV, Jiang H, Polak M (2007c). Bed with integrated personalized ventilation for minimizing cross infection. In: Proceedings of Roomvent 2007, 10th International Conference on Air Distribution in Rooms, Helsinki, Finland.

    Google Scholar 

  • Nilsson HO, Holmér I (2004). Comfort climate evaluation with thermal manikin methods and computer simulation models, Indoor Air, 13: 28–37.

    Article  Google Scholar 

  • Russo JS (2010). A detailed and Systematic Investigation of Personal Ventilation Systems. Phd Dissertation, Syracuse University.

    Google Scholar 

  • Russo JS, Dang TQ, Khalifa EH (2009). Computational analysis of reduced-mixing personal ventilation jets. Building and Environment, 44: 1559–1567.

    Article  Google Scholar 

  • STAR-CCM. (2012). Tutorial Gui de of STAR-CCM.

  • Vander JA, Sherman HJ, Luciano SD (1994). Human Physiology: The Mechanisms of Body Function. New York: McGraw-Hill.

    Google Scholar 

  • Villi G, Carli MC (2014). Detailing the effects of geometry approximation and grid simplification on the capability of a CFD model to address the benchmark test case for flow around a computer simulated person. Building Simulation, 7: 35–55.

    Article  Google Scholar 

  • Xu W, Chen Q (2000). Simulation of mixed convection flow in a room with a two-layer turbulence model. Indoor Air, 10: 306–314.

    Article  Google Scholar 

  • Xu W, Chen Q (2001). A two-layer turbulence model for simulating indoor airflow Part II. Applications. Building and Environment, 33: 627–639.

    Google Scholar 

  • Zhuang R, Li X, Tu J (2014). CFD study of the effects of furniture layout on indoor air quality under typical office ventilation schemes. Building Simulation, 7: 263–275.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Meng Kong.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kong, M., Zhang, J. & Wang, J. Air and air contaminant flows in office cubicles with and without personal ventilation: A CFD modeling and simulation study. Build. Simul. 8, 381–392 (2015). https://doi.org/10.1007/s12273-015-0219-6

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-015-0219-6

Keywords

Navigation