Skip to main content
Log in

A Web-based searchable system to confirm magnetic resonance compatibility of implantable medical devices in Japan: a preliminary study

  • Published:
Radiological Physics and Technology Aims and scope Submit manuscript

Abstract

Confirmation of the magnetic resonance (MR) compatibility of implanted medical devices (IMDs) is mandatory before conducting magnetic resonance imaging (MRI) examinations. In Japan, few such confirmation methods are in use, and they are time-consuming. This study aimed to develop a Web-based searchable MR safety information system to confirm IMD compatibility and to evaluate the usefulness of the system. First, MR safety information for intravascular stents and stent grafts sold in Japan was gathered by interviewing 20 manufacturers. These IMDs were categorized based on the descriptions available on medical package inserts as: “MR Safe,” “MR Conditional,” “MR Unsafe,” “Unknown,” and “No Medical Package Insert Available”. An MR safety information database for implants was created based on previously proposed item lists. Finally, a Web-based searchable system was developed using this database. A questionnaire was given to health-care personnel in Japan to evaluate the usefulness of this system. Seventy-nine datasets were collected using information provided by 12 manufacturers and by investigating the medical packaging of the IMDs. Although the datasets must be updated by collecting data from other manufacturers, this system facilitates the easy and rapid acquisition of MR safety information for IMDs, thereby improving the safety of MRI examinations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Organisation for Economic Co-operation and Development. https://data.oecd.org/healthcare/magnetic-resonance-imaging-mri-exams.htm. Accessed 10 Feb 2017.

  2. Organisation for Economic Co-operation and Development. https://data.oecd.org/healtheqt/magnetic-resonance-imaging-mri-units.htm, Accessed 10 Feb 2017.

  3. Levine GN, Gomes AS, Arai AE, Bluemke DA, Flamm SD, et al. Safety of magnetic resonance imaging in patients with cardiovascular devices an American Heart Association Scientific Statement from the committee on diagnostic and interventional cardiac catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the society for cardiovascular magnetic resonance. Circulation. 2007;116:2878–91.

    Article  PubMed  Google Scholar 

  4. Shellock FG, Crues JV. MR procedures: biologic effects, safety, and patient care. Radiology. 2004;232:635–52.

    Article  PubMed  Google Scholar 

  5. Doi T, Yamatani Y, Ueyama T, Nishiki S, Ogura A, et al. An investigative report concerning safety and management in the magnetic resonance environment: there are more accidents than expected. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2011;67:895–904.

    Article  PubMed  Google Scholar 

  6. Expert Panel on MR Safety, Kanal E, Barkovich AJ, Bell C, Borgstede JP, Bradley WG Jr, et al. ACR guidance document on MR safe practices: 2013. J Magn Reson Imaging. 2013;37:501–30.

    Article  Google Scholar 

  7. Sawyer-Glover AM, Shellock FG. Pre-MRI procedure screening: recommendations and safety considerations for biomedical implants and devices. J Magn Reson Imaging. 2000;12:92–106.

    Article  CAS  PubMed  Google Scholar 

  8. Ferreira AM, Costa F, Tralhão A, Marques H, Cardim N, Adragão P. MRI-conditional pacemakers: current perspectives. Med Devices (Auckl). 2014;7:115–24.

    Article  Google Scholar 

  9. ASTM International. ASTM F2182-11a: standard test method for measurement of radio frequency induced heating on or near passive implants during magnetic resonance imaging. 2011.

  10. International Electrotechnical Commission. IEC 60601-2-33: medical electrical equipment-Part 2-33, particular requirements for the safety of magnetic resonance equipment for medical diagnosis, 3rd edn. 2010.

  11. ASTM International. ASTM F2119-07: standard test method for evaluation of MR image artifacts from passive implant. 2007.

  12. ASTM International. ASTM F2052-06 e1: standard test method for measurement of magnetically induced displacement force on medical devices in the magnetic resonance environment. 2006.

  13. ASTM International. ASTM F2213-06: standard test method for measurement of magnetically induced torque on medical devices in the magnetic resonance environment. 2006.

  14. Pharmaceuticals and Medical Devices Agency. http://www.pmda.go.jp/PmdaSearch/kikiSearch/, Accessed 15 April 2014.

  15. Kuroda K. Research reports of ministry of health, labour and welfare ministry. 2015.

  16. Woods TO. Establishing safety and compatibility of passive implants in the magnetic resonance (MR) environment. Guidance for industry and FDA staff. Silver Spring: Center for Devices and Radiological Health; 2008.

    Google Scholar 

  17. Woods TO, Delfino JG, Shein MJ. Response to standardized MR terminology and reporting of implants and devices as recommended by the American College of radiology subcommittee on MR safety. Radiology. 2016;279:906–9.

    Article  PubMed  Google Scholar 

  18. Shellock FG, Woods TO, Crues JV. MR labeling information for implants and devices: explanation of terminology. Radiology. 2009;253:26–30.

    Article  PubMed  Google Scholar 

  19. ASTM International. ASTM F2503-13: standard practice for marking medical devices and other items for safety in the magnetic resonance environment. 2013.

  20. Fujiwara Y, Kata T, Fujimoto S, Yachida T, Kanamoto M, et al. Development of an magnetic resonance imaging safety management system for metallic biomedical products using an magnetic resonance compatibility database and inquiry-based patient records. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2014;70:1413–9.

    Article  PubMed  Google Scholar 

  21. Kobayashi M, Kobayashi M, Someno T, Uchiyama H, Ono Y. Collection of information regarding implants, internal and external metallic objects for MRI examinations. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2011;67:1314–9.

    Article  PubMed  Google Scholar 

  22. Shellock FG. MRISafety.com. Web site. http://www.mrisafety.com. Accessed 1 April 2016.

  23. Gardner J. MagResource. http://www.magresource.com. Accessed 3 August 2016.

Download references

Acknowledgements

The authors would like to thank Yoshiyuki Ishimori, Ph.D., for his useful discussions and support.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yasuhiro Fujiwara.

Ethics declarations

Conflict of interest

The authors Hitoshi Fujioka, Tomoko Watanabe, and Maiko Sekiguchi are employees of Medie Corporation, Ltd., and collaborating researchers. This study was supported in part by a research grant from Medie Corporation, Ltd.

Human and animal rights

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Declaration of Helsinki and its later amendments, or comparable ethical standards.

Informed consent

Informed consent was obtained from all individual participants included in this study.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Fujiwara, Y., Fujioka, H., Watanabe, T. et al. A Web-based searchable system to confirm magnetic resonance compatibility of implantable medical devices in Japan: a preliminary study. Radiol Phys Technol 10, 340–348 (2017). https://doi.org/10.1007/s12194-017-0409-2

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12194-017-0409-2

Keywords

Navigation