Objective

To evaluate the degree of interobserver agreement in the visual interpretation of 123I-FP-CIT studies and to investigate for potential associations between visual and semi-quantitative parameters.

Methods

Eighty-nine 123I-FP-CIT studies were blindly reviewed by 3 independent observers: a consultant, a resident doctor and a radiographer. They classified every study as either “normal” or “abnormal” and assigned visual 123I-FP-CIT uptake scores (2: normal, 1: reduced and 0: no uptake) in basal ganglia nuclei (right and left putamina and caudate nuclei) on every scan. Striatal 123I-FP-CIT binding ratios were calculated using crescent-ROI software. The interobserver agreement for the interpretation of studies and for visual score assignment was evaluated by means of κ statistics. We investigated for associations of binding ratios with visual scores and clinical parameters; patients’ clinical diagnoses served as the reference standard.

Results

There was excellent interobserver agreement (κ 0.89–0.93) in classifying studies as “normal” or “abnormal” and fine agreement in assignment of visual scores (κ 0.71–0.80 for putamina and 0.50–0.79 for caudate nuclei). Nuclei with scores of 1 and 0 showed significantly reduced binding ratios (about 30 and 50%, respectively) compared with the nuclei scored as 2. ROC analysis indicated the optimal cutoff point of striatal binding ratio at 3.8 (sensitivity 98.5%, specificity 95%) for the detection of parkinsonian syndromes. Striatal binding ratios were negatively associated with age in normal subjects and disease duration in Parkinson’s disease patients.

Conclusion

Visual interpretation of 123I-FP-CIT studies showed very good interobserver agreement. We found significant associations among visual, semi-quantitative and clinical parameters.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Benamer TS, Patterson J, Grosset DG, Booij J, de Bruin K, van Royen E, et al. Accurate differentiation of parkinsonism and essential tremor using visual assessment of [123I]-FP-CIT SPECT imaging: the [123I]-FP-CIT study group. Mov Disord. 2000;15(3):503–10.

    Article  PubMed  CAS  Google Scholar 

  2. Kemp PM. Imaging the dopaminergic system in suspected parkinsonism, drug induced movement disorders, and Lewy body dementia. Nucl Med Commun. 2005;26(2):87–96.

    Article  PubMed  Google Scholar 

  3. Scherfler C, Schwarz J, Antonini A, Grosset D, Valldeoriola F, Marek K, et al. Role of DAT-SPECT in the diagnostic work up of parkinsonism. Mov Disord. 2007;22(9):1229–38.

    Article  PubMed  Google Scholar 

  4. Vlaar AM, van Kroonenburgh MJ, Kessels AG, Weber WE. Meta-analysis of the literature on diagnostic accuracy of SPECT in parkinsonian syndromes. BMC Neurol. 2007;7:27.

    Article  PubMed  Google Scholar 

  5. Vlaar AM, de Nijs T, Kessels AG, Vreeling FW, Winogrodzka A, Mess WH, et al. Diagnostic value of 123I-ioflupane and 123I-iodobenzamide SPECT scans in 248 patients with parkinsonian syndromes. Eur Neurol. 2008;59(5):258–66.

    Article  PubMed  Google Scholar 

  6. Catafau AM, Tolosa E. Impact of dopamine transporter SPECT using 123I-Ioflupane on diagnosis and management of patients with clinically uncertain parkinsonian syndromes. Mov Disord. 2004;19(10):1175–82.

    Article  PubMed  Google Scholar 

  7. Tolosa E, Borght TV, Moreno E. Accuracy of DaTSCAN (123I-Ioflupane) SPECT in diagnosis of patients with clinically uncertain parkinsonism: 2-year follow-up of an open-label study. Mov Disord. 2007;22(16):2346–51.

    Article  PubMed  Google Scholar 

  8. Marshall VL, Reininger CB, Marquardt M, Patterson J, Hadley DM, Oertel WH, et al. Parkinson’s disease is overdiagnosed clinically at baseline in diagnostically uncertain cases: a 3-year European multicenter study with repeat [123I]FP-CIT SPECT. Mov Disord. 2009;24(4):500–8.

    Article  PubMed  Google Scholar 

  9. Acton PD, Newberg A, Plossl K, Mozley PD. Comparison of region-of-interest analysis and human observers in the diagnosis of Parkinson’s disease using [99mTc]TRODAT-1 and SPECT. Phys Med Biol. 2006;51(3):575–85.

    Article  PubMed  Google Scholar 

  10. Deuschl G, Bain P, Brin M. Consensus statement of the Movement Disorder Society on Tremor. Ad Hoc Scientific Committee. Mov Disord. 1998;13(Suppl 3):2–23.

    PubMed  Google Scholar 

  11. Gibb WR, Lees AJ. The relevance of the Lewy body to the pathogenesis of idiopathic Parkinson’s disease. J Neurol Neurosurg Psychiatry. 1988;51(6):745–52.

    Article  PubMed  CAS  Google Scholar 

  12. Darcourt J, Booij J, Tatsch K, Varrone A, Vander Borght T, Kapucu OL, et al. EANM procedure guidelines for brain neurotransmission SPECT using (123)I-labelled dopamine transporter ligands, version 2. Eur J Nucl Med Mol Imaging. 2010;37(2):443–50.

    Article  PubMed  CAS  Google Scholar 

  13. Booij J, Kemp P. Dopamine transporter imaging with [(123)I]FP-CIT SPECT: potential effects of drugs. Eur J Nucl Med Mol Imaging. 2008;35(2):424–38.

    Article  PubMed  CAS  Google Scholar 

  14. McKeith I, O’Brien J, Walker Z, Tatsch K, Booij J, Darcourt J, et al. Sensitivity and specificity of dopamine transporter imaging with 123I-FP-CIT SPECT in dementia with Lewy bodies: a phase III, multicentre study. Lancet Neurol. 2007;6(4):305–13.

    Article  PubMed  Google Scholar 

  15. Tondeur MC, Hambye AS, Dethy S, Ham HR. Interobserver reproducibility of the interpretation of I-123 FP-CIT single-photon emission computed tomography. Nucl Med Commun. 2010;31(8):717–25.

    Article  PubMed  Google Scholar 

  16. Dickson JC, Tossici-Bolt L, Sera T, Erlandsson K, Varrone A, Tatsch K, et al. The impact of reconstruction method on the quantification of DaTSCAN images. Eur J Nucl Med Mol Imaging. 2010;37(1):23–35.

    Article  PubMed  Google Scholar 

  17. Staff RT, Ahearn TS, Wilson K, Counsell CE, Taylor K, Caslake R, et al. Shape analysis of 123I-N-omega-fluoropropyl-2-beta-carbomethoxy-3beta-(4-iodophenyl) nortropane single-photon emission computed tomography images in the assessment of patients with parkinsonian syndromes. Nucl Med Commun. 2009;30(3):194–201.

    Article  PubMed  CAS  Google Scholar 

  18. Badiavas K, Molyvda E, Iakovou I, Tsolaki M, Psarrakos K, Karatzas N. SPECT imaging evaluation in movement disorders: far beyond visual assessment. Eur J Nucl Med Mol Imaging. 2011;38(4):764–73.

    Article  PubMed  Google Scholar 

  19. Kagi G, Bhatia KP, Tolosa E. The role of DAT-SPECT in movement disorders. J Neurol Neurosurg Psychiatry. 2010;81(1):5–12.

    Article  PubMed  CAS  Google Scholar 

  20. Pirker W, Djamshidian S, Asenbaum S, Gerschlager W, Tribl G, Hoffmann M, et al. Progression of dopaminergic degeneration in Parkinson’s disease and atypical parkinsonism: a longitudinal beta-CIT SPECT study. Mov Disord. 2002;17(1):45–53.

    Article  PubMed  Google Scholar 

  21. Benamer HT, Patterson J, Wyper DJ, Hadley DM, Macphee GJ, Grosset DG. Correlation of Parkinson’s disease severity and duration with 123I-FP-CIT SPECT striatal uptake. Mov Disord. 2000;15(4):692–8.

    Article  PubMed  CAS  Google Scholar 

  22. Hughes AJ, Daniel SE, Ben-Shlomo Y, Lees AJ. The accuracy of diagnosis of parkinsonian syndromes in a specialist movement disorder service. Brain. 2002;125(Pt 4):861–70.

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

The authors acknowledge the contribution of D Karakalos, P Aggelidakis and N Matikas, neurologists, Neurology Clinic, “Evaggelismos” General Hospital.

Conflict of interest

The authors have no financial disclosure of interest.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Phivi Rondogianni.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Papathanasiou, N., Rondogianni, P., Chroni, P. et al. Interobserver variability, and visual and quantitative parameters of 123I-FP-CIT SPECT (DaTSCAN) studies. Ann Nucl Med 26, 234–240 (2012). https://doi.org/10.1007/s12149-011-0564-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12149-011-0564-1

Keywords

Navigation