Abstract
Objective
Three-dimensional stereotactic surface projection (3D-SSP) analyses have been widely used in dementia imaging studies. However, 3D-SSP sometimes shows paradoxical results on amyloid positron emission tomography (PET) analyses. This is thought to be caused by errors in anatomical standardization (AS) based on an 18F-fluorodeoxyglucose (FDG) template. We developed a new method of 3D-SSP analysis for amyloid PET imaging, and used it to analyze 11C-labeled 2-(2-[2-dimethylaminothiazol-5-yl]ethenyl)-6-(2-[fluoro]ethoxy)benzoxazole (BF-227) PET images of subjects with mild cognitive impairment (MCI) and Alzheimer’s disease (AD).
Methods
The subjects were 20 with MCI, 19 patients with AD, and 17 healthy controls. Twelve subjects with MCI were followed up for 3 years or more, and conversion to AD was seen in 6 cases. All subjects underwent PET with both FDG and BF-227. For AS and 3D-SSP analyses of PET data, Neurostat (University of Washington, WA, USA) was used. Method 1 involves AS for BF-227 images using an FDG template. In this study, we developed a new method (Method 2) for AS: First, an FDG image was subjected to AS using an FDG template. Then, the BF-227 image of the same patient was registered to the FDG image, and AS was performed using the transformation parameters calculated for AS of the corresponding FDG images. Regional values were normalized by the average value obtained at the cerebellum and values were calculated for the frontal, parietal, temporal, and occipital lobes. For statistical comparison of the 3 groups, we applied one-way analysis of variance followed by the Bonferroni post hoc test. For statistical comparison between converters and non-converters, the t test was applied. Statistical significance was defined as p < 0.05.
Results
Among the 56 cases we studied, Method 1 demonstrated slight distortions after AS of the image in 16 cases and heavy distortions in 4 cases in which the distortions were not observed with Method 2. Both methods demonstrated that the values in AD and MCI patients were significantly higher than those in the controls, in the parietal, temporal, and occipital lobes. However, only Method 2 showed significant differences in the frontal lobes. In addition, Method 2 could demonstrate a significantly higher value in MCI-to-AD converters in the parietal and frontal lobes.
Conclusions
Method 2 corrects AS errors that often occur when using Method 1, and has made appropriate 3D-SSP analysis of amyloid PET imaging possible. This new method of 3D-SSP analysis for BF-227 PET could prove useful for detecting differences between normal groups and AD and MCI groups, and between converters and non-converters.
Similar content being viewed by others
References
Minoshima S, Koeppe RA, Frey KA, Kuhl DE. Anatomic standardization: linear scaling and nonlinear warping of functional brain images. J Nucl Med. 1994;35:1528–37.
Minoshima S, Frey KA, Koeppe RA, Foster NL, Kuhl DE. A diagnostic approach in Alzheimer’s disease using three-dimensional stereotactic surface projections of fluorine-18-FDG PET. J Nucl Med. 1995;36:1238–48.
Klunk WE, Engler H, Nordberg A, Wang Y, Blomqvist G, Holt DP, et al. Imaging brain amyloid in Alzheimer’s disease with Pittsburgh Compound-B. Ann Neurol. 2004;55:306–19.
Nordberg A. PET imaging of amyloid in Alzheimer’s disease. Lancet Neurol. 2004;3:519–27.
Kudo Y. Development of amyloid imaging PET probes for an early diagnosis of Alzheimer’s disease. Minim Invasive Ther Allied Technol. 2006;15:209–13.
Kudo Y, Okamura N, Furumoto S, Tashiro M, Furukawa K, Maruyama M, et al. 2-(2-[2-Dimethylaminothiazol-5-yl]ethenyl)-6-(2-[fluoro]ethoxy)benzoxazole: a novel PET agent for in vivo detection of dense amyloid plaques in Alzheimer’s disease patients. J Nucl Med. 2007;48:553–61.
Friston KJ, Holmes AP, Worsley KJ, Poline JB, Frith C, Frackowiak RSJ. Statistical parametric maps in functional imaging: a general linear approach. Hum Brain Mapp. 1995;2:189–210.
Mikhno A, Devanand D, Pelton G, Cuasay K, Gunn R, Upton N, et al. Voxel-based analysis of 11C-PIB scans for diagnosing Alzheimer’s disease. J Nucl Med. 2008;49:1262–9.
Ziolko SK, Weissfeld LA, Klunk WE, Mathis CA, Hoge JA, Lopresti BJ, et al. Evaluation of voxel-based methods for the statistical analysis of PIB PET amyloid imaging studies in Alzheimer’s disease. Neuroimage. 2006;33:94–102.
de Leon MJ, Convit A, Wolf OT, Tarshish CY, DeSanti S, Rusinek H, et al. Prediction of cognitive decline in normal elderly subjects with 2-[(18)F]fluoro-2-deoxy-d-glucose/positron-emission tomography (FDG/PET). Proc Natl Acad Sci. 2001;98:10966–71.
Minoshima S, Giordani B, Berent S, Frey KA, Foster NL, Kuhl DE. Metabolic reduction in the posterior cingulate cortex in very early Alzheimer’s disease. Ann Neurol. 1997;42:85–94.
Mosconi L, De Santi S, Li Y, Li J, Zhan J, Tsui WH, et al. Visual rating of medial temporal lobe metabolism in mild cognitive impairment and Alzheimer’s disease using FDG-PET. Eur J Nucl Med Mol Imaging. 2006;33:210–21.
Maes F, Collignon A, Vandermeulen D, Marchal G, Suetens P. Multimodality image registration by maximization of mutual information. IEEE Trans Med Imaging. 1997;16:187–98.
Maes F, Vandermeulen D, Suetens P. Comparative evaluation of multiresolution optimization strategies for multimodality image registration by maximization of mutual information. Med Image Anal. 1999;3:373–86.
Pluim JP, Maintz JB, Viergever MA. Image registration by maximization of combined mutual information and gradient information. IEEE Trans Med Imaging. 2000;19:809–14.
Pluim JP, Maintz JB, Viergever MA. Mutual-information-based registration of medical images: a survey. IEEE Trans Med Imaging. 2003;22:986–1004.
Waragai M, Okamura N, Furukawa K, Tashiro M, Furumoto S, Funaki Y, et al. Comparison study of amyloid PET and voxel-based morphometry analysis in mild cognitive impairment and Alzheimer’s disease. J Neurol Sci. 2009;285:100–8.
Furukawa K, Okamura N, Tashiro M, Waragai M, Furumoto S, Iwata R, et al. Amyloid PET in mild cognitive impairment and Alzheimer’s disease with BF-227: comparison to FDG-PET. J Neurol. 2010;257:721–7.
Shao H, Okamura N, Sugi K, Furumoto S, Furukawa K, Tashiro M, et al. Voxel-based analysis of amyloid positron emission tomography probe [C]BF-227 uptake in mild cognitive impairment and alzheimer’s disease. Dement Geriatr Cogn Disord. 2010;30:101–11.
Onishi H, Matsutake Y, Kawashima H, Matsutomo N, Amijima H. Comparative study of anatomical normalization errors in SPM and 3D-SSP using digital brain phantom. Ann Nucl Med. 2011;25:59–67.
Acknowledgments
We appreciate the technical assistance provided by Seiichi Watanuki of CYRIC in Tohoku University (Sendai, Japan) and Frank Thiele of Philips Research North America (NY, USA).
Sources of funding for the article
None.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kaneta, T., Okamura, N., Minoshima, S. et al. A modified method of 3D-SSP analysis for amyloid PET imaging using [11C]BF-227. Ann Nucl Med 25, 732–739 (2011). https://doi.org/10.1007/s12149-011-0518-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12149-011-0518-7