Abstract
Objective
To compare the fat content and contamination of expressed breast milk (EBM) before and after storage (30 d) in hard polypropylene containers (HC) and soft polyethylene bags (SB) containers.
Methods
Ninety specimens of EBM were collected into HC and separated into two HC and two SB. The fat content of each specimen of EBM in HC and SB was measured and cultures were performed. The specimens in the second HC and SB containers were kept frozen for 30 d before thawing and then measuring the fat content and performing cultures.
Results
The means ± SD of the fat content of fresh and thawed EBM in HC were 2.98 ± 0.97 and 2.66 ± 0.88 g/100 ml, respectively, with a loss of 0.32 g/100 ml (p < 0.001). The means ± SD of the fat content of fresh and thawed EBM in SB were 3.06 ± 1.00 and 2.77 ± 0.91 g/100 ml, respectively, with a mean loss of 0.29 g/100 ml during storage (p < 0.001). The loss of fat content during frozen storage did not differ significantly between the two types of containers (p = 0.53). All bacterial cultures of fresh and thawed EBM in HC and SB showed only nonpathogenic organisms.
Conclusions
SB can replace HC for the long-term storage of frozen EBM of up to 30 d without deleterious effects on fat loss or contamination.
Similar content being viewed by others
References
Section on breastfeeding. Breastfeeding and the use of human milk. Pediatrics. 2012;129:e827–41.
Williamson MT, Murti PK. Effects of storage, time, temperature, and composition of containers on biologic components of human milk. J Hum Lact. 1996;12:31–5.
Manohar AA, Williamson M, Koppikar GV. Effect of storage of colostrum in various containers. Indian Pediatr. 1997;34:293–5.
Goldblum RM, Goldman AS, Garza C, Johnson CA, Nichols BL. Human milk banking. II. Relative stability of immunologic factors in stored colostrum. Acta Paediatr Scand. 1982;71:143–4.
Lawrence RA, Lawrence RM. Breastfeeding: A Guide for the Medical Profession. 7th ed. Maryland Heights: Elsevier Mosby; 2011.
ABM clinical protocol #8: human milk storage information for home use for full-term infants (Original protocol March 2004; Revision #1 March 2010). Breastfeed Med. 2010;5:127–30.
Thatrimontrichai A, Janjindamai W. Safety of superfortification of human milk fortifier in preterm human milk. Asian Biomed. 2011;5:825–30.
Agostoni C, Buonocore G, Carnielli VP, et al. ESPGHAN Committee on Nurtrition, Enteral nutrient supply for preterm infants: commentary from the European Society of Paediatric Gastroenterology, Hepatology and Nutrition Committee on Nutrition. J Pediatr Gastroenterol Nutr. 2010;50:85–91.
Ben XM. Nutritional management of newborn infants: practical guidelines. World J Gastroenterol. 2008;14:6133–9.
Kleyn DH, Lynch JM, Barbano DM, Bloom MJ, Mitchell MW. Determination of fat in raw and processed milks by the Gerber method: collaborative study. J AOAC Int. 2001;84:1499–508.
Rueda R, Ramirez M, Garcia-Salmeron JL, Maldonado J, Gil A. Gestational age and origin of human milk influence total lipid and fatty acid contents. Ann Nutr Metab. 1998;42:12–22.
Zeisel SH, Char D, Sheard NF. Choline, phosphatidylcholine and sphingomyelin in human and bovine milk and infant formulas. J Nutr. 1986;116:50–8.
Aksit S, Ozkayin N, Caglayan S. Effect of sucking characteristics on breast milk creamatocrit. Paediatr Perinat Epidemiol. 2002;16:355–60.
Lubetzky R, Littner Y, Mimouni FB, Dollberg S, Mandel D. Circadian variations in fat content of expressed breast milk from mothers of preterm infants. J Am Coll Nutr. 2006;25:151–4.
Lubetzky R, Mimouni FB, Dollberg S, Salomon M, Mandel D. Consistent circadian variations in creamatocrit over the first 7 wk of lactation: a longitudinal study. Breastfeed Med. 2007;2:15–8.
Thatrimontrichai A, Janjindamai W, Puwanant M. Fat loss in thawed breast milk: comparison between refrigerator and warm water. Indian Pediatr. 2012;49:877–80.
Jackson DA, Imong SM, Silprasert A, et al. Circadian variation in fat concentration of breast-milk in a rural northern Thai population. Br J Nutr. 1988;59:349–63.
Jackson DA, Imong SM, Silprasert A, et al. Estimation of 24 h breast-milk fat concentration and fat intake in rural northern Thailand. Br J Nutr. 1988;59:365–71.
Pardou A, Serruys E, Mascart-Lemone F, Dramaix M, Vis HL. Human milk banking: influence of storage processes and of bacterial contamination on some milk constituents. Biol Neonate. 1994;65:302–9.
Friend BA, Shahani KM, Long CA, Vaughn LA. The effect of processing and storage on key enzymes, B vitamins, and lipids of mature human milk. I. Evaluation of fresh samples and effects of freezing and frozen storage. Pediatr Res. 1983;17:61–4.
Boo NY, Nordiah AJ, Alfizah H, Nor-Rohaini AH, Lim VK. Contamination of breast milk obtained by manual expression and breast pumps in mothers of very low birthweight infants. J Hosp Infect. 2001;49:274–81.
Brown SL, Bright RA, Dwyer DE, Foxman B. Breast pump adverse events: reports to the food and drug administration. J Hum Lact. 2005;21:169–74.
Garza C, Johnson CA, Harrist R, Nichols BL. Effects of methods of collection and storage on nutrients in human milk. Early Hum Dev. 1982;6:295–303.
Acknowledgments
The authors thank Dr. Alan Geater and Miss Walailuk Jitpiboon of the Epidemiology Unit, Faculty of Medicine, Prince of Songkla University, for statistical analysis, and Ms. Jude Hall of the International Affairs Office, Faculty of Medicine, Prince of Songkla University, for editing the manuscript.
Conflict of Interest
None.
Role of Funding Source
This study was supported by the Faculty of Medicine, Prince of Songkla University.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Janjindamai, W., Thatrimontrichai, A., Maneenil, G. et al. Soft Plastic Bag Instead of Hard Plastic Container for Long-term Storage of Breast Milk. Indian J Pediatr 80, 809–813 (2013). https://doi.org/10.1007/s12098-013-0963-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12098-013-0963-5