Skip to main content

Advertisement

Log in

ECR ion source based low energy ion beam facility

  • Proceedings Of The Ninth International Conference On Heavy Ion Accelerator Technology (HIAT 2001)—Part I
  • Published:
Pramana Aims and scope Submit manuscript

Abstract

Mass analyzed highly charged ion beams of energy ranging from a few keV to a few MeV plays an important role in various aspects of research in modern physics. In this paper a unique low energy ion beam facility (LEIBF) set up at Nuclear Science Centre (NSC) for providing low and medium energy multiply charged ion beams ranging from a few keV to a few MeV for research in materials sciences, atomic and molecular physics is described. One of the important features of this facility is the availability of relatively large currents of multiply charged positive ions from an electron cyclotron resonance (ECR) source placed entirely on a high voltage platform. All the electronic and vacuum systems related to the ECR source including 10 GHz ultra high frequency (UHF) transmitter, high voltage power supplies for extractor and Einzel lens are placed on a high voltage platform. All the equipments are controlled using a personal computer at ground potential through optical fibers for high voltage isolation. Some of the experimental facilities available are also described.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. R Geller, B Jacquot and M Pontonnier, Rev. Sci. Instrum. 56, 1505 (1985)

    Article  ADS  Google Scholar 

  2. T A Antaya and S Gammino, Rev. Sci. Instrum. 65, 1723 (1994)

    Article  ADS  Google Scholar 

  3. D Kanjilal et al, Indian J. Pure Appl. Phys. 39, 25 (2001)

    Google Scholar 

  4. A G Drentje, A Girard, D Hitz and G Melin, Rev. Sci. Intrum. 67, 953 (1996)

    Article  ADS  Google Scholar 

  5. R Becker, Rev. Sci. Instrum. 63, 2756 (1992)

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kumar, P., Rodrigues, G., Rao, U.K. et al. ECR ion source based low energy ion beam facility. Pramana - J Phys 59, 805–809 (2002). https://doi.org/10.1007/s12043-002-0094-4

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12043-002-0094-4

Keywords

PACS No.

Navigation