Skip to main content

Advertisement

Log in

A Proposal for a New Protocol for Sonographic Assessment of the Optic Nerve Sheath Diameter: The CLOSED Protocol

  • Viewpoint
  • Published:
Neurocritical Care Aims and scope Submit manuscript

A Letters to the editor to this article was published on 28 September 2023

A Response to Letter To The Editor to this article was published on 28 September 2023

Abstract

Measuring and monitoring of intracranial pressure is considered standard of care in patients with suspected intracranial hypertension. Sonographic assessment of the optic nerve sheath diameter (ONSD) has been promising and potentially useful for noninvasive intracranial hypertension screening. ONSD measurements are easy to perform, repeatable at bedside, fast, low cost, and radiation-free. However, they are still burdened by inter-rater variability, lack of ultrasound (US) setting standardization (e.g., US frequency, focus depth, etc.), and possible artifacts. To overcome this problem, we propose the CLOSED protocol associated with equipment specifications, as a guide to minimize the occurrence of such artifacts enabling a more reliable and accurate measurement. We suggest that color Doppler could be used as a new standard evaluation for the ONSD.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

Abbreviations

ALARA:

As low as reasonably achievable

CRA:

Central retinal artery

CRV:

Central retinal vein

ICP:

Intracranial pressure

ICU:

Intensive care unit

IIH:

Idiopathic intracranial hypertension

iNPH:

Idiopathic normal pressure hydrocephalus

I SPTA.3 :

Spatial-peak temporal-average intensity

MI:

Mechanical index

ms:

Millisecond

ON:

Optic nerve

ONSD:

Optic nerve sheath diameter

PRF:

Pulse repetition frequency

SAH:

Subarachnoid hemorrhage

TI:

Thermal index

TIC:

Thermal index cranium

TIS_as:

Soft tissue thermal index at surface

US:

Ultrasound

References

  1. Rossi S, Buzzi F, Paparella A, Mainini P, Stocchetti N. Complications and safety associated with ICP monitoring: a study of 542 patients. In: Marmarou A, et al., editors. Intracranial pressure and neuromonitoring in brain injury., Acta neurochirurgica supplementsVienna: Springer; 1998.

    Google Scholar 

  2. Rebuck JA, Murry KR, Rhoney DH, Michael DB, Coplin WM. Infection related to intracranial pressure monitors in adults: analysis of risk factors and antibiotic prophylaxis. J Neurol Neurosurg Psychiatry. 2000;69:381–4.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  3. Ma R, Rowland D, Judge A, Calisto A, Jayamohan J, Johnson D, et al. Complications following intracranial pressure monitoring in children: a 6-year single-center experience. J Neurosurg Pediatr. 2018;21:278–83.

    Article  PubMed  Google Scholar 

  4. Robba C, Cardim D, Tajsic T, Pietersen J, Bulman M, Donnelly J, et al. Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: a prospective observational study. PLoS Med. 2017;14:e1002356.

    Article  PubMed  PubMed Central  Google Scholar 

  5. Robba C, Santori G, Czosnyka M, Corradi F, Bragazzi N, Padayachy L, et al. Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis. Intensive Care Med. 2018;44:1284–94.

    Article  PubMed  Google Scholar 

  6. Moretti R, Pizzi B, Cassini F, Vivaldi N. Reliability of optic nerve ultrasound for the evaluation of patients with spontaneous intracranial hemorrhage. Neurocrit Care. 2009;11:406.

    Article  PubMed  Google Scholar 

  7. Lochner P, Coppo L, Cantello R, Nardone R, Naldi A, Leone MA, et al. Intra- and interobserver reliability of transorbital sonographic assessment of the optic nerve sheath diameter and optic nerve diameter in healthy adults. J Ultrasound. 2016;11:406.

    Google Scholar 

  8. Popovic D, Khoo M, Lee S. Noninvasive monitoring of intracranial pressure. Recent Patents Biomed Eng. 2009;2:165–79.

    Article  Google Scholar 

  9. Zeiler FA, Ziesmann MT, Goeres P, Unger B, Park J, Karakitsos D, et al. A unique method for estimating the reliability learning curve of optic nerve sheath diameter ultrasound measurement. Crit Ultrasound J. 2016;8:9.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Helmke K, Hansen HC. Fundamentals of transorbital sonographic: evaluation of optic nerve sheath expansion under intracranial hypertension. II. Patient study. Pediatr Radiol. 1996;26:701–10.

    Article  CAS  PubMed  Google Scholar 

  11. Helmke K, Hansen HC. Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension. I. Experimental study. Pediatr Radiol. 1996;26:701–5.

    Article  CAS  PubMed  Google Scholar 

  12. Hansen H-C, Helmke K. Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests. J Neurosurg. 1997;87:34–40.

    Article  CAS  PubMed  Google Scholar 

  13. Tsutsumi S, Rhoton AL. Microsurgical anatomy of the central retinal artery. Neurosurgery. 2006;59:870–9.

    Article  PubMed  Google Scholar 

  14. Ertl M, Barinka F, Torka E, Altmann M, Pfister K, Helbig H, et al. Ocular color-coded sonography—a promising tool for neurologists and intensive care physicians. Ultraschall Med. 2014;35:422–31.

    Article  CAS  PubMed  Google Scholar 

  15. Pribojszki M, Komáromi K, Csomor A, Vörös ES. Tortuous optic nerve-ECR 2017/C-2914. 2017.

  16. Feldman MK, Katyal S, Blackwood MS. US artifacts. RadioGraphics. 2009;24:1179–89.

    Article  Google Scholar 

  17. Baad M, Lu ZF, Reiser I, Paushter D. Clinical significance of US artifacts. RadioGraphics. 2017;37:1408–23.

    Article  PubMed  Google Scholar 

  18. Food and Drug Administration. Marketing clearance of diagnostic ultrasound systems and transducers—draft guidance for industry and Food and Drug Administration Staff. 2019. https://www.fda.gov/media/71100/download. Accessed 30 Aug 2019.

  19. Hewick SA, Fairhead AC, Culy JC, Atta HR. A comparison of 10 MHz and 20 MHz ultrasound probes in imaging the eye and orbit. Br J Ophthalmol. 2004;88:551–5.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  20. Coleman DJ, Silverman RH, Chabi A, Rondeau MJ, Shung KK, Cannata J, et al. High-resolution ultrasonic imaging of the posterior segment. Ophthalmology. 2004;111:1344–51.

    Article  PubMed  Google Scholar 

  21. Toms DA. The mechanical index, ultrasound practices, and the ALARA principle. J Ultrasound Med. 2006;25:560–1.

    Article  PubMed  Google Scholar 

  22. Shah S, Kimberly H, Marill K, Noble V. Ultrasound techniques to measure the optic nerve sheath: is a specialized probe necessary? Med Sci Monit. 2009;15:63–8.

    Google Scholar 

  23. Nelson TR, Fowlkes JB, Abramowicz JS, Church CC. Ultrasound biosafety considerations for the practicing sonographer and sonologist. J Ultrasound Med. 2009;28:139–50.

    Article  PubMed  Google Scholar 

  24. Safety Group of the British Medical Ultrasound Society. Guidelines for the safe use of diagnostic ultrasound equipment. Ultrasound. 2010;18:52–9.

    Article  Google Scholar 

  25. Romagnuolo L, Tayal V, Tomaszewski C, Saunders T, Norton HJ. Optic nerve sheath diameter does not change with patient position. Am J Emerg Med. 2005;23:686–8.

    Article  PubMed  Google Scholar 

  26. Roque PJ, Hatch N, Barr L, Wu TS. Bedside ocular ultrasound. Crit Care Clin. 2014;30:227–41.

    Article  PubMed  Google Scholar 

  27. Rubens DJ, Bhatt S, Nedelka S, Cullinan J. Doppler artifacts and pitfalls. Radiol Clin N Am. 2006;44:805–35.

    Article  PubMed  Google Scholar 

  28. Shankar H, Pagel PS. Potential adverse ultrasound-related biological effects: a critical review. Anesthesiology. 2011;115:1109–24.

    Article  PubMed  Google Scholar 

  29. Ertl M, Gamulescu M-A, Schlachetzki F. Application of orbital sonography in neurology. In: Thoirs K, editor. sonography. Rijeka: InTech; 2012.

    Google Scholar 

  30. Rasulo FBR. Transcranial Doppler and optic nerve sonography. J Cardiothorac Vasc Anesth. 2019;33:S38–52.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

We thank Dr. Monica Ferri for color Doppler learning skills, Dr. Veronica Salvatore for assistance with US settings support, and Dr. Franziska Lohmeyer for the revision of our manuscript.

Funding

The author(s) received no financial support for the research, authorship, and/or publication of this article.

Author information

Authors and Affiliations

Authors

Contributions

Aspide, Bertolini was involved in conception and design. Aspide, Bertolini, Albini was involved in acquisition of data. Aspide, Bertolini, Biasucci contributed in drafting the article. All authors critically revised the article and reviewed the submitted version of manuscript. Albini was also involved in Technical/material support. Mazzatenta, Palandri, and Biasucci contributed in study supervision.

Corresponding author

Correspondence to Raffaele Aspide.

Ethics declarations

Conflicts of Interest

The authors declare that the article content was composed in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Ethical approval

The local Institutional Review Board approved the present study. CLOSED protocol adhered to ethical standards and Helsinki Declaration.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Aspide, R., Bertolini, G., Albini Riccioli, L. et al. A Proposal for a New Protocol for Sonographic Assessment of the Optic Nerve Sheath Diameter: The CLOSED Protocol. Neurocrit Care 32, 327–332 (2020). https://doi.org/10.1007/s12028-019-00853-x

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12028-019-00853-x

Keywords

Navigation