Skip to main content
Log in

High variation in hypoxanthine determination after analytical treatment of vitreous humor samples

  • Technical Report
  • Published:
Forensic Science, Medicine, and Pathology Aims and scope Submit manuscript

Abstract

In the field of legal medicine the correct determination of the time of death is of great importance because an error in calculating the post-mortem interval (PMI) could be crucial in a criminal investigation. The quantification of hypoxanthine (Hx) concentration in the vitreous humor (VH) as a means to estimate PMI is useful when dealing with a recent time interval of death and has several advantages over other biological matrices. However, due to its viscous nature, VH has to be liquefied prior to its analysis, and the different procedures to liquefy it may cause alterations in Hx concentration, and hence in estimation of PMI. The aim of this study was to determine differences in Hx concentration after applying several pre-analytical treatments to different aliquots of the same VH sample. Enzymatic digestion, sonication, centrifugation and heat were the liquefying methods applied to reduce the viscosity of 105 VH samples. Analysis was performed using solid phase extraction and liquid chromatography in tandem with mass spectrometry. Statistically significant differences in the measured Hx concentrations were found between enzymatic digestion and the other three methods analyzed (sonication, centrifugation, and heat). Additionally, high data dispersion was found under heat treatment but was not observed for centrifugation or sonication, where similar and more moderate results were found. We conclude that high variations in Hx determination are observed when enzymatic digestion or heat treatment is used and we therefore recommend sonication or centrifugation to quantify Hx concentration in the VH.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

References

  1. Sturner WQ, Gantner GE Jr. The postmortem interval. A study of potassium in the vitreous humor. Am J Clin Pathol. 1964;42:137–44.

    CAS  PubMed  Google Scholar 

  2. Coe JI. Vitreous potassium as a measure of the postmortem interval: an historical review and critical evaluation. Forensic Sci Int. 1989;42:201–13.

    Article  CAS  PubMed  Google Scholar 

  3. James RA, Hoadley PA, Sampson BG. Determination of postmortem interval by sampling vitreous humour. Am J Forensic Med Pathol. 1997;18:158–62.

    Article  CAS  PubMed  Google Scholar 

  4. Rognum TO, Hauge S, Oyasaeter S, Saugstad OD. A new biochemical method for estimation of post-mortem time. Forensic Sci Int. 1991;51:139–46.

    Article  CAS  PubMed  Google Scholar 

  5. Muñoz JI, Suárez-Peñaranda JM, Otero XL, Rodríguez-Calvo MS, Costas E, Miguéns X, Concheiro L. A new perspective in the estimation of post-mortem interval (PMI) based on vitreous. J Forensic Sci. 2001;46:209–14.

    PubMed  Google Scholar 

  6. Henssge C, Knight B, Krompecher T, Madea B, Nokses L. Estimation of the time since death in the early post-mortem period. 2nd ed. London: Arnold; 2002.

    Google Scholar 

  7. Madea B, Henssge C. Time since death. In: Payne-James J, Busuttil A, editors. Forensic medicine: clinical and pathological aspects. London: Greenwich Medical Media Limited; 2003. p. 91–114.

    Google Scholar 

  8. Jashnani KD, Kale SA, Rupani AB. Vitreous humor: biochemical constituents in estimation of postmortem interval. J Forensic Sci. 2010;55:1523–7.

    Article  PubMed  Google Scholar 

  9. Mithell R, Charlwood C, Thomas SD, Bellis M, Langlois NE. An audit of the contribution to post-mortem examination diagnosis of individual analyte results obtained from biochemical analysis of the vitreous. Forensic Sci Med Pathol. 2013;9:515–20.

    Article  Google Scholar 

  10. Muñoz JI, Costas E, Rodríguez-Calvo MS, Suárez-Penaranda JM, Lopez-Rivadulla M, Concheiro L. A high-performance liquid chromatography method for hypoxanthine determination in vitreous humour: application to estimation of post mortem interval. Hum Exp Toxicol. 2006;25:279–81.

    Article  PubMed  Google Scholar 

  11. Tagliaro F, Manetto G, Cittadini F, Marchetti D, Bortolotti F, Marigo M. Capillary zone electrophoresis of potassium in human vitreous humour: validation of a new method. J Chromatogr B Biomed Sci Appl. 1999;733:273–9.

    Article  CAS  PubMed  Google Scholar 

  12. Myo-Thaik-Oo, Tanaka E, Oikawa H, Aita K, Tanno K, Yamazaki K, Misawa S. No significant differences in the postmortem interval in Myanmar and Japanese using vitreous potassium levels. J Clin Forensic Med. 2002;9:70–3.

  13. Madea B, Rödig A. Time of death dependent criteria in vitreous humor: accuracy of estimating the time since death. Forensic Sci Int. 2006;164:87–92.

    Article  CAS  PubMed  Google Scholar 

  14. Muñoz-Barús JI, Febrero-Bande M, Cadarso-Suárez C. Flexible regression models for estimating postmortem interval (PMI) in forensic medicine. Stat Med. 2008;27:5026–38.

    Article  PubMed  Google Scholar 

  15. Muñoz-Barús JI, Rodríguez-Calvo MS, Suárez-Peñaranda JM, Vieira DN, Cadarso-Suárez C, Febrero-Bande M. PMICALC: an R code-based software for estimating post-mortem interval (PMI) compatible with Windows, Mac and Linux operating systems. Forensic Sci Int. 2010;194:49–52.

    Article  PubMed  Google Scholar 

  16. Passos ML, Santos AM, Pereira AI, Santos JR, Santos AJ, Saraiva ML, Lima JL. Estimation of postmortem interval by hypoxanthine and potassium evalutation in vitreous humor with a sequential injection system. Talanta. 2009;79:1094–9.

    Article  CAS  PubMed  Google Scholar 

  17. Madea B, Käferstein H, Hermann N, Sticht G. Hypoxanthine in vitreous humor and cerebrospinal fluid–a marker of postmortem interval and prolonged (vital) hypoxia? Remarks also on hypoxanthine in SIDS. Forensic Sci Int. 1994;65:19–31.

    Article  CAS  PubMed  Google Scholar 

  18. Muñoz-Barús JI, Suárez-Peñaranda J, Otero XL, Rodríguez-Calvo MS, Costas E, Miguéns X, Concheiro L. Improved estimation of postmortem interval based on differential behaviour of vitreous potassium and hypoxanthine in death by hanging. Forensic Sci Int. 2002;125:67–74.

    Article  PubMed  Google Scholar 

  19. Lendoiro E, Cordeiro C, Rodríguez-Calvo MS, Vieira DN, Suárez-Peñaranda JM, López-Rivadulla M, Muñoz-Barús JI. Applications of tandem mass spectrometry (LC-MSMS) in estimating the post-mortem interval using the biochemistry of the vitreous humor. Forensic Sci Int. 2012;223:160–4.

    Article  CAS  PubMed  Google Scholar 

  20. Blana SA, Mubhoff F, Hoeller T, Fimmers R, Madea B. Variations in vitreous humor chemical values as a result of pre-analytical treatment. Forensic Sci Int. 2011;210:263–70.

    Article  CAS  PubMed  Google Scholar 

  21. Coe JI, Apple FS. Variations in vitreous humor chemical values as a result of instrumentation. J Forensic Sci. 1985;30:828–35.

    CAS  PubMed  Google Scholar 

  22. R Development Core Team. R: a language and environment for statistical computing. R Foundation for Statistical Computing. 2010. http://www.R-project.org.

  23. Altman DG, Bland JM. Measurement in medicine: the analysis of method comparison studies. J R Stat Soc. 1983;32:307–17.

    Google Scholar 

  24. Carstensen B, Gurrin L, Ekstrom C, Figurski M. MethComp: Functions for analysis of agreement in method comparison studies. 2013. http://CRAN.Rproject.org/package=MethComp.

  25. Thierauf A, Musshoff F, Madea B. Post-mortem biochemical investigations of vitreous humor. Forensic Sci Int. 2009;192:78–82.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to José I. Muñoz-Barús.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Camba, A., Lendoiro, E., Cordeiro, C. et al. High variation in hypoxanthine determination after analytical treatment of vitreous humor samples. Forensic Sci Med Pathol 10, 627–633 (2014). https://doi.org/10.1007/s12024-014-9590-3

Download citation

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12024-014-9590-3

Keywords

Navigation