Skip to main content
Log in

Second-generation Extensively Porous-coated THA Stems at Minimum 10-year Followup

  • Symposium: Papers Presented at the Annual Closed Meeting of the International Hip Society
  • Published:
Clinical Orthopaedics and Related Research®

Abstract

The relatively high prevalence of thigh pain and stress shielding associated with the AML porous-coated cementless femoral component led to the development of the Prodigy®, a femoral component with more extensive porous-coating and a distal polished bullet tip with medial diaphyseal relief to potentially decrease the flexural rigidity. We prospectively evaluated a cohort of 100 consecutive cementless total hip arthroplasties performed using this device. The minimum followup was 10 years (mean, 11.4 years; range, 10–12 years). At 10-year followup, 69 of the 86 patients (82 hips) were living, 14 patients with 15 hips were deceased, and three patients with three hips were lost to followup. No hips required a stem revision. Two patients (two hips) complained of thigh pain. All hips were bone ingrown. Distal tip radiolucencies and osteolysis occurred in 13 hips (17%) and none, respectively. Twenty-one hips (28%) demonstrated moderate or severe stress shielding. Only further followup will determine if this could be a clinical problem or one with revision surgery. These results encourage the authors to continue using second-generation extensively coated stems in their primary total hip arthroplasty constructs.

Level of Evidence: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2A–C

Similar content being viewed by others

References

  1. Aldinger PR, Breusch SJ, Lukoschek M, Mau H, Ewerbeck V, Thomsen M. A ten- to 15-year follow-up of the Cementless Spotorno stem. J Bone Joint Surg Br. 2003;85:209–214.

    Article  PubMed  CAS  Google Scholar 

  2. Aldinger PR, Thomsen M, Mau H, Ewerbeck V, Breusch SJ. Cementless Spotorno tapered titanium stems: Excellent 10–15 year survival in 141 young patients. Acta Orthop. 2003;74:253–258.

    Article  Google Scholar 

  3. Amstutz HC, Thomas BJ, Jinnah R, Kim W, Grogan T, Yale C. Treatment of primary osteoarthritis of the hip. A comparison of total joint and surface replacement arthroplasty. J Bone Joint Surg Am. 1984;66:228–241.

    PubMed  CAS  Google Scholar 

  4. Bellamy N, Campbell J, Stevens J, Pilch L, Stewart C, Mahmood Z. Validation study of a computerized version of the Western Ontario and McMaster Universities VA3.0 Osteoarthritis Index. J Rheumatol. 1997;24:2413–2415.

    PubMed  CAS  Google Scholar 

  5. Bourne RB, Rorabeck CH, Patterson JJ, Guerin J. Tapered titanium cementless total hip replacements: a 10- to 13-year follow-up study. Clin Orthop Relat Res. 2001;393:112–120.

    Article  PubMed  Google Scholar 

  6. Bugbee WD, Culpepper WJ, Engh CA Jr, Engh CA. Long-term clinical consequences of stress-shielding after total hip arthroplasty without cement. J Bone Joint Surg Am. 1997;79:1007–1012.

    PubMed  CAS  Google Scholar 

  7. Butler JBV, Lansky D, Duwelius PJ. Prospective evaluation of total hip arthroplasty with a cementless, anatomically designed, porous-coated femoral implant: mean 11-year follow-up. J Arthroplasty. 2005;20:709–716.

    Article  PubMed  CAS  Google Scholar 

  8. Callaghan JJ, Templeton JE, Liu SS, Warth LC, Chung YY. Improved results using extensively coated THA stems at minimum 5-year followup. Clin Orthop Relat Res. 2006;453:91–96.

    Article  PubMed  Google Scholar 

  9. Chen CJ, Xenos JS, McAuley JP, Young A, Engh CA Sr Second-generation porous-coated cementless total hip arthroplasties have high survival. Clin Orthop Relat Res. 2006;451:121–127.

    Article  PubMed  Google Scholar 

  10. Engh CA, Bobyn JD. The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop Relat Res. 1988;231:7–28.

    PubMed  Google Scholar 

  11. Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res. 1990;257:107–128.

    PubMed  Google Scholar 

  12. Engh CA Jr, Culpepper WJ, Engh CA. Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty. J Bone Joint Surg Am. 1997;79:177–184.

    Article  PubMed  Google Scholar 

  13. Engh CA Sr, Culpepper WJ II. Femoral fixation in primary total hip arthroplasty. Orthopedics. 1997;20:771–773.

    PubMed  Google Scholar 

  14. Grubl A, Chiari C, Gruber M, Kaider A, Gottsauner-Wolf F. Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up. J Bone Joint Surg Am. 2002;84:425–431.

    PubMed  Google Scholar 

  15. Gruen TA, McNeice GM, Amstutz HC. “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17–27.

    PubMed  Google Scholar 

  16. Ha Y, Kim HJ, Kim S, Kim T, Koo K. THA using an anatomic stem in patients with femoral head osteonecrosis. Clin Orthop Relat Res. 2008;466:1141–1147.

    Article  PubMed  Google Scholar 

  17. Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.

    PubMed  CAS  Google Scholar 

  18. Heekin RD, Callaghan JJ, Hopkinson WJ, Savory CG, Xenos JS. The porous-coated anatomic total hip prosthesis, inserted without cement. J Bone Joint Surg Am. 1993;75:77–91.

    PubMed  CAS  Google Scholar 

  19. Johnston RC, Fitzgerald RH Jr, Harris WH, Poss R, Muller ME, Sledge CB. Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results. J Bone Joint Surg Am. 1990;72:161–168.

    PubMed  CAS  Google Scholar 

  20. Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:457–481.

    Article  Google Scholar 

  21. Kronick JL, Barba ML, Paprosky WG. Extensively coated femoral components in young patients. Clin Orthop Relat Res. 1997;344:263–274.

    Article  PubMed  Google Scholar 

  22. Kubo T, Inoue S, Maeda T, Arai Y, Hirakawa K, Wu Y, Suehara H, Ogura T, Hirasawa Y. Cementless Lord total hip arthroplasty: cup loosening common after minimum 10-year follow-up of 103 hips. Acta Orthop. 2001;72:585–590.

    Article  CAS  Google Scholar 

  23. Loudon JR, Charnley J. Subsidence of the femoral prosthesis in total hip replacement in relation to the design of the stem. J Bone Joint Surg Br. 1980;62:450–453.

    PubMed  Google Scholar 

  24. Marshall AD, Mokris JG, Reitman RD, Dandar A, Mauerhan DR. Cementless titanium tapered-wedge femoral stem: 10- to 15-year follow-up. J Arthroplasty. 2004;19:546–552.

    Article  PubMed  Google Scholar 

  25. Massin P, Schmidt L, Engh CA. Evaluation of cementless acetabular component migration. An experimental study. J Arthroplasty. 1989;4:245–251.

    Article  PubMed  CAS  Google Scholar 

  26. Palm L, Jacobsson S, Ivarsson I. Hydroxyapatite coating improves 8- to 10-year performance of the link RS cementless femoral stem. J Arthroplasty. 2002;17:172–175.

    Article  PubMed  Google Scholar 

  27. Reitman RD, Emerson R, Higgins L, Head W. Thirteen year results of total hip arthroplasty using a taped titanium femoral component inserted without cement in patients with Type C bone. J Arthroplasty. 2003;18:116–121.

    Article  PubMed  Google Scholar 

  28. Schramm M, Keck F, Hohmann D, Pitto RP. Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up. Arch Orthop Trauma Surg. 2000;120:407–412.

    Article  PubMed  CAS  Google Scholar 

  29. Trebse R, Milosev I, Kovac S, Mikek M, Pisot V. Poor Results from the isoelastic total hip replacement: 14–17 year follow-up of 149 cementless prostheses. Acta Orthop. 2005;76:169–176.

    Article  PubMed  Google Scholar 

  30. Ware JE, Sherbourne CD. The MOS 36-Item Short Form Health Survey (SF-36): conceptual framework and item selection. Med Care. 1992;30:473–483.

    Article  PubMed  Google Scholar 

  31. Xenos JS, Callaghan JJ, Heekin D, Hopkinson WJ, Savory CG, Moore MS. The porous-coated anatomic total hip prosthesis, inserted without cement: A prospective study with a minimum of ten years of follow-up. J Bone Joint Surg Am. 1999;81:74–82.

    PubMed  CAS  Google Scholar 

Download references

Acknowledgments

We thank Rhonda Chalus, RN, for her work in helping to complete this study.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to John J. Callaghan MD.

Additional information

One of the authors (JJC) has received royalties and consulting fees from DePuy (Warsaw, IN), a Johnson & Johnson company.

Each author certifies that his institution has approved the reporting of these cases, that all investigations were conducted in conformity with ethical principles of research, and that informed consent for participation in the study was obtained.

About this article

Cite this article

Hennessy, D.W., Callaghan, J.J. & Liu, S.S. Second-generation Extensively Porous-coated THA Stems at Minimum 10-year Followup. Clin Orthop Relat Res 467, 2290–2296 (2009). https://doi.org/10.1007/s11999-009-0831-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11999-009-0831-9

Keywords

Navigation