Fifty years have passed since the first total hip arthroplasty of the modern era was performed. At this, the vantage point, it is reasonable to review these five decades, inquiring behind the single dominating observation that, in its current form, this operation is one of the most successful of all surgical procedures for the management of end-stage human disease. What are the generic lessons that can be derived from the experience? Succinctly, five major observations appear valuable. They are “skunk works,” “Pasteur’s motto,” “the totally unexpected,” “research solutions,” and “the role of alternatives.” “Skunk works,” an industrial management term, might be characterized as an innovative endeavor that is offline and off-budget resulting from the relentless pursuit of a vivid dream by creative zealots who eschew defeat. Pasteur’s motto dealt with serendipity, which was crucial to total hip arthroplasty progress. The totally unexpected is represented by an entirely new manmade disease, “periprosthetic osteolysis.” The research solutions are represented by the complex, sophisticated contemporary research that has unraveled periprosthetic osteolysis and suggested modes of correction. Finally, the application of “alternatives” has characterized major progress. Importantly, these, or similar generic observations, may provide insights into important progress in the future.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Bragdon CR, Kwon YM, Geller JA, Greene ME, Freiberg AA, Harris WH, Malchau H. Minimum 6-year followup of highly crosslinked polyethylene in THA. Clin Orthop Relat Res. 2007;465:122–127.

    PubMed  Google Scholar 

  2. Burroughs BR, Rubash HE, Harris WH. Femoral head sizes larger than 32 mm against highly crosslinked polyethylene. Clin Orthop Relat Res. 2002;405:150–157.

    Article  PubMed  Google Scholar 

  3. Charnley J. A clean-air operating enclosure. Br J Surg. 1964;51:202–205.

    Article  PubMed  CAS  Google Scholar 

  4. Charnley J. The Man and the Hip. New York, NY: Springer; 1990:120–143.

    Google Scholar 

  5. Coventry MB, Nolan DR, Beckenbaugh RD. ‘Delayed’ prophylactic anticoagulation: a study of results and complications in 2,012 total hip arthroplasties. J Bone Joint Surg Am. 1973;55:1487–1497.

    PubMed  CAS  Google Scholar 

  6. Crawford WJ, Hillman F, Charnley J. A clinical trial of prophylactic anticoagulant therapy in elective hip surgery. In: Internal Publication 14. Wiggan, UK: Centre for Hip Surgery, Wrightington Hospital; 1968.

  7. Galante J, Rostoker W, Lueck R, Ray RD. Sintered fiber metal composites as a basis for attachment of implants to bone. J Bone Joint Surg Am. 1971;53:101–114.

    PubMed  CAS  Google Scholar 

  8. Hamadouche M, Boutin P, Daussange J, Bolander ME, Sedel L. Alumina-on-alumina total hip arthroplasty. J Bone Joint Surg Am. 2002;84:69–77.

    PubMed  Google Scholar 

  9. Harris WH, Schiller AL, Scholler JM, Freiberg RA, Scott R. Extensive localized bone resorption in the femur following total hip replacement. J Bone Joint Surg Am. 1976;58:612–618.

    PubMed  CAS  Google Scholar 

  10. Jacobs JJ, Roebuck KA, Archibeck M, Hallab NJ, Glant TT. Osteolysis: basic science. Clin Orthop Relat Res. 2001;393:71–77.

    Article  PubMed  Google Scholar 

  11. Jasty M, Goetz DD, Bragdon CR, Lee KR, Hanson AE, Elder JR, Harris WH. Wear of polyethylene acetabular components in total hip arthroplasty: an analysis of one hundred and twenty-eight components retrieved at autopsy. J Bone Joint Surg Am. 1997;79:349–358.

    Article  PubMed  CAS  Google Scholar 

  12. Kabo JM, Gebhard JS, Loren G, Amstutz HC. In vivo wear of polyethylene acetabular components. J Bone Joint Surg Br. 1993;75:254–258.

    PubMed  CAS  Google Scholar 

  13. Maloney WJ, Herzwurm P, Paprosky W, Rubash HE, Engh CE. Treatment of pelvic osteolysis association with a stable acetabular component inserted without cement as part of a total hip replacement. J Bone Joint Surg Am. 1997;79:1628–1634.

    PubMed  CAS  Google Scholar 

  14. McKellop H, Shen FW, Lu B, Campbell P, Salovey R. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res. 1999;17:157–167.

    Article  PubMed  CAS  Google Scholar 

  15. Muratoglu OK, Bragdon CR, O’Connor DO, Jasty M, Harris WH. A novel method of cross-linking ultra-high molecular weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the HAP Paul Award. J Arthroplasty. 2001;16:149–160.

    Article  PubMed  CAS  Google Scholar 

  16. Nehme A, Lewallen D, Hanssen AD. Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty. Clin Orthop Relat Res. 2004;429:201–208.

    Article  PubMed  Google Scholar 

  17. Oral E, Christensen SD, Malhi AS, Wannomae KK, Muratoglu OK. Wear resistance and mechanical properties of highly crosslinked UHMWPE doped with vitamin E. J Arthroplasty. 2006;21:58–59.

    Article  Google Scholar 

  18. Oral E, Wannomae KK, Hawkins N, Harris WH, Muratoglu OK. α-Tocopherol-doped irradiated UHMWPE for high fatigue resistance and low wear. Biomaterials. 2004;25:5515–5522.

    Article  PubMed  CAS  Google Scholar 

  19. Schreurs BW, Bolder SBT, Gardeniers JMW, Verdonschot N, Sloof TJJH, Veth RPH. Acetabular revision with impacted morcellized cancellous bone grafting and a cemented cup. A fifteen to twenty year follow up. J Bone Joint Surg Br. 2004;86:492–497.

    PubMed  CAS  Google Scholar 

  20. Silva M, Heisel C, Schmalzried TP. Metal-on-metal total hip replacement. Clin Orthop Relat Res. 2005;430:53–61.

    Article  PubMed  Google Scholar 

  21. Sporer SM, Paprosky WG. The use of trabecular metal acetabular component and trabecular metal augment for severe acetabular defects. J Arthroplasty. 2006;21(Suppl 2):83–86.

    Article  PubMed  Google Scholar 

  22. Tsiridis E, Narvani AA, Haddad FS, Timperley JA, Gie GA. Impaction femoral allografting and cemented revision for periprosthetic femoral fractures. J Bone Joint Surg Br. 2004;86:1124–1132.

    Article  PubMed  CAS  Google Scholar 

  23. Willert H-G, Semlitsch M. Reactions of the articular wear capsule to wear products of artificial joint prostheses. J Biomed Mater Res. 1977;11:157–164.

    Article  PubMed  CAS  Google Scholar 

  24. Willert H-G, Semlitsch M. Tissue reactions to plastic and metallic wear products of joint endoprostheses. Clin Orthop Relat Res. 1996;333:4–14.

    PubMed  Google Scholar 

  25. Wilson PD Jr, Amstutz HC, Czernicki A, Salvati EA, Mendes DG. Total hip replacement with fixation by acrylic cement. J Bone Joint Surg Am. 1972;54:207–236.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to William H. Harris MD, DSc.

Additional information

The author has received funding from the William H. Harris, MD, Foundation.

About this article

Cite this article

Harris, W.H. The First 50 Years of Total Hip Arthroplasty: Lessons Learned. Clin Orthop Relat Res 467, 28–31 (2009). https://doi.org/10.1007/s11999-008-0467-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11999-008-0467-1

Keywords

Navigation