Abstract
Different bearing surfaces, including alumina-on-alumina, have been used to avoid osteolysis.
We prospectively followed 288 patients (319 hips) in which an alumina-on-alumina cup was used with a hydroxyapatite stem. The patients’ mean age was 52.7 (range, 14–70 years), and the minimum followup was 3 years (mean, 4.7 years; range, 3–8 years). At final followup, five cups (including one with an alumina liner fracture) and two stems underwent revision. The cumulative probability of not having a revision of one or both components for any cause was 97% (95% confidence interval, 94.7%–99.1%). No patient spontaneously reported any noises from the hip and none reported noises when specifically questioned. All patients who had not undergone revision had good clinical results, but five of these patients had radiographic cup loosening at last followup. These data suggest alumina-on-alumina prostheses had reasonable outcomes after 5 years. One acetabular component fractured from trauma. We observed no linear femoral head penetration. Continued followup will be required to determine if reduction in wear between the alumina-on-alumina bearings results in less osteolysis and loosening.
Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Similar content being viewed by others
References
Bal BS, Aleto TJ, Garino JP, Toni A, Hendricks KJ. Ceramic-on ceramic versus ceramic-on-polyethylene bearings in total hip arthroplasty: results of a multicenter prospective randomized study and update of modern ceramic total hip trials in the United States. Hip International. 2005;15:129–135.
Bizot P, Hannouche D, Nizard R, Witvoet J, Sedel L. Hybrid alumina total hip arthroplasty using press-fit metal-backed socket in patients younger than 55 years. A six- to 11-year evaluation. J Bone Joint Surg Br. 2004;86:190–194.
Bizot P, Nizard R, Hamadouche M, Hannouche D, Sedel L. Prevention of wear and osteolysis. Alumina-on-alumina bearing. Clin Orthop Relat Res. 2001;393:85–93.
Bobyn JD, Toh KK, Hacking SA, Tanzer M, Krygier JJ. Tissue response to porous tantalum acetabular cups: a canine model. J Arthroplasty. 1999;14:347–354.
Boutin P. Total hip arthroplasty using a ceramic prosthesis. The Classic. Clin Orthop Relat Res. 2000;379:3–11.
Capello WN, D’Antonio JA, Manley MT, Feinberg JR. Hydroxyapatite in total hip arthroplasty. Clinical results and critical issues. Clin Orthop Relat Res. 1998;355:200–211.
D’Antonio J, Capello W, Manley M, Bierbaum B. New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty. J Arthroplasty. 2002;17:390–397.
DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.
Devane PA, Horne JG, Martin K, Coldham G, Krause B. Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris. J Arthroplasty. 1997;12:256–266.
Dorr LD, Faugere M-C, Mackel AM, Gruen TA, Bognar B, Malluche HH. Structural and cellular assessment of bone quality of proximal femur. Bone. 1993;14:231–242.
Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding and clinical results. J Bone Joint Surg Br. 1987;69:45–55.
Engh CA, Glassman AH, Suthers KE. The case for porous-coated hip implants. The femoral side. Clin Orthop Relat Res. 1990;261:63–81.
Garcia-Cimbrelo E, Cruz-Pardos A, Cordero J, Sánchez-Sotelo J. Low-friction arthroplasty in patients younger than 40 years. 20- to 25-year results. J Arthroplasty. 2000;15:825–832.
García-Cimbrelo E, Martínez-Sayanes JM, Minuesa A, Munuera L. Mittelmeier ceramic-ceramic prosthesis after ten years. J Arthroplasty. 1996;11:773–781.
Garino J. Modern ceramic-on-ceramic total hip systems in the United States. Clin Orthop Relat Res. 2000;379:41–47.
Geesink RG, Hoefnagels NHM. Six-year results of hydroxyapatite-coated total hip replacement. J Bone Joint Surg Br. 1995;77:534–547.
Goetz DD, Smith JJ, Harris WH. The prevalence of femoral osteolysis associated with components inserted with or without cement in total hip replacements. J Bone Joint Surg Am. 1994;76:1121–1128.
Gruen TA, McNeice GM, Amstutz HC. ‘Modes of failure’ of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17–27.
Hamadouche M, Boutin P, Daussange J, Bolander ME, Sedel L. Alumina-on-alumina total hip arthroplasty. A minimum 18.5-year follow-up study. J Bone Joint Surg Am. 2002;84:69–77.
Hannouche D, Nich C, Bizot P, Meunier A, Nizard R, Sedel L. Fractures of ceramic bearings. History and present status. Clin Orthop Relat Res. 2003;417:19–26.
Huo MH, Martin RP, Zatorsky LE, Keggi KJ. Cementless total hip arthroplasties using ceramic-on-ceramic articulation in young patients: a minimum 5-year follow-up study. J Arthroplasty. 1996;11:673–678.
Johnston RC, Fitzgerald RH, Harris WH, Poss R, Müller ME, Sledge CB. Clinical and radiographic evaluation of total hip arthroplasty. A standard system of terminology for reporting results. J Bone Joint Surg Am. 1990;72:161–168.
Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:457–481.
Kim Y-H, Kim J-S, Cho S-H. A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads. A prospective, randomised study. J Bone Joint Surg Br. 2001;83:742–750.
Lai K-A, Shen W-J, Chen C-H, Yang C-Y, Hu W-P, Chang G-L. Failure of hydroxyapatite-coated acetabular cups. Ten-year follow-up of a 85 Landos Atoll arthroplasties. J Bone Joint Surg Br. 2002;84:641–646.
Merle D’Aubigné R, Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am. 1954;36:451–475.
Moore MS, McAuley JP, Young AM, Engh CA Sr. Radiographic signs of osseointegration in porous-coated acetabular components. Clin Orthop Relat Res. 2006;444:176–183.
Park Y-S, Hwang S-K, Choy W-S, Kim Y-S, Moon Y-W, Lim S-J. Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing. J Bone Joint Surg Am. 2006;88:780–787.
Poggie RA, Turgeon TR, Coutts RD. Failure analysis of a ceramic bearing acetabular component. J Bone Joint Surg Am. 2007;89:367–380.
Riska EB. Ceramic endoprosthesis in total hip arthroplasty. Clin Orthop Relat Res. 1993;297:87–94.
Sedel L. Evolution of alumina-on-alumina implants. A review. Clin Orthop Relat Res. 2000;379:48–54.
Sedel L, Kerboull L, Christel P. Alumina on alumina hip replacement results and survivorship in young patients. J Bone Joint Surg Br. 1990;72:658–663.
Sedel L, Nizard RS, Kerboull L, Witwoet J. Alumina-alumina hip replacement in patients younger than 50 years old. Clin Orthop Relat Res. 1994;298:175–183.
Soballe K. Hydroxyapatite ceramic coating for bone implant fixation. Acta Orthop Scand. 1993;255(Suppl):1–58.
Toni A, Traina F, Stea S, Sudanese A, Visentin M, Bordini B, Squarzoni S. Early diagnosis of ceramic liner fracture. Guidelines based on a twelve-year clinical experience. J Bone Joint Surg Am. 2006;88(Suppl 4):55–63.
Walter WL, O’Toole GC, Walter WK, Ellis A, Zicat BA. Squeaking in ceramic-on-ceramic hips. The importance of acetabular component orientation. J Arthroplasty. 2007;22:496–503.
Author information
Authors and Affiliations
Corresponding author
Additional information
Each author certifies that he or she has no commercial associations (eg, consultancies, stock ownership, equity interest, patent/licensing arrangements, etc) that might pose a conflict of interest in connection with the submitted article.
Each author certifies that his or her institution has approved the human protocol for this investigation, that all investigations were conducted in conformity with ethical principles of research, and that informed consent was obtained.
About this article
Cite this article
Garcia-Cimbrelo, E., Garcia-Rey, E., Murcia-Mazón, A. et al. Alumina-on-Alumina in THA. Clin Orthop Relat Res 466, 309–316 (2008). https://doi.org/10.1007/s11999-007-0042-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11999-007-0042-1