Summary
CPAP (continuous positive airway pressure) is the therapy of choice for obstructive sleep apnea syndrome (OSAS). About 70 % of patients on CPAP use their device for at least 70 % of nights with an application time of at least 4 hours per night. Compared to subjective CPAP-application time, pressure monitors show that patients tend to overestimate their CPAP compliance by about one hour; nevertheless pressure monitoring has shown that more than 70 % of patients use their CPAP device for at least 4 hours per night. Even in the long-term application of CPAP it has been shown that approximately 60 % of patients use their CPAP device for more that 5 hours per night. Severity of breathing disorder and disturbance of sleep architecture, degree of daytime sleepiness and patient satisfaction with diagnostic and therapeutic procedures, respectively, are good predictors of long-term CPAP compliance. CPAP compliance can be increased by intensive patient education.
Zusammenfassung
CPAP (continuous positive airway pressure) ist die Therapie der Wahl des obstruktiven Schlafapnoe-Syndroms (OSAS). Ca. 70 % der Patienten mit eingeleiteter CPAP-Therapie nutzen das Gerat dauerhaft wahrend 70 % der Nachte für mindestens 4 Stunden pro Nacht. Im Vergleich zur objektiv über Druckmesser registrierten Nutzungsdauer wird die subjektive Anwendungsdauer vom Patienten um ca. eine Stunde pro Nacht überschatzt, dennoch betragt die objektive Nutzungsdauer mindestens 4 Stunden pro Nacht bei > 70 % der Patienten. Auch über längere Nachbeobachtungszeitraume lassen sich Nutzungsdauern von über 5 Stunden pro Nacht bei über 60 % der Patienten feststellen. Prädiktoren für eine gute CPAP-Langzeitcompliance sind der Schweregrad der Atmungsstörung bzw. der Störung der Schlafarchitektur, der Ausprägungsgrad der Tagesschläfrigkeit sowie die Patientenzufriedenheit mit dem diagnostischen und therapeutischen Procedere. Eine Steigerung der CPAP-Compliance ist durch intensive Patientenschulung zu erzielen
Similar content being viewed by others
Literatur
Barnes M, Houston D, Worsnop CJ, Neill AM, Mykytyn IJ, Kay , Trinder J, Saunders NA, McEvoy RD, Pierce RJ (2002) A randomized controlled trial of continuous positive airway pressure in mild obstructive sleep apnea. Am J Respir Crit Care Med 165:773–780
Bizieux-Thaminy A, Gagnadoux F, Binquet C, Meslier N, Person C, Racineux JL (2005) Acceptation à long termed traitement par pression positive continue. Etude retrospective de 137 patients appareillés entre 1985 et 1993 au CHU d’Angers. Rev Mal Respir 22:951–957
Budhiraja R, Parthasarathy S, Drake CL, Roth T, Sharief I, Budhiraja P, Saunders V, Hudgel DW (2007) Early CPAP use identifies subsequent adherence to CPAP therapy. Sleep 30:320–324
Chasens ER, Pack AI, Maislin G, Dinges DF, Weaver TE (2005) Claustrophobia and adherence to CPAP treatment. Western Journal of Nursing Research 27:307–321
Drake CL, Day R, Hudgel D, Stefadu Y, Parks M, Syron ML, Roth T (2003) Sleep during titration predicts continuous positive airway pressure compliance. Sleep 26:308–311
Engleman HM, Asgari-Jirhandeh N, McLeod AL, Ramsay CF, Deary IJ, Douglas NJ (1996) Self-reported use of CPAP and benefits of CPAP Therapy. A patient survey. Chest 109:1470–1476
Engleman HM, Martin SE, Douglas NJ (1994) Compliance with CPAP therapy in patients with the sleep apnoea/hypopnoea syndrome. Thorax 49:263–266
Hohenhaus-Beer A, Gleixner M, Fichter J (1995) Langzeitbeobachtung der CPAP-Therapie bei Patienten mit obstruktiver Schlafapnoe. Wien Med Wschr 17:512–514
Hui DSC, Choy DKL, Li TST, Ko FWS, Wong KK, Chan JK, Lai CKW (2001) Determinants of continuous positive airway pressure compliance in a group of Chinese patients with obstructive sleep apnea. Chest 120:170–176
Hui DSC, Choy DKL, Wong LKS, KO FWS, LI TST, Woo J, Kay R (2002) Prevalence of sleep-disordered breathing and continuous positive airway pressure compliance. Results in Chinese patients with first-ever ischemic stroke. Chest 122:852–860
Kaplan V, Bingisser R, Li Y, Hess T, Russi EW, Bloch KE (1996) Compliance mit nasaler Überdrucktherapie (CPAP) bei obstruktivem Schlafapnoesyndrom. Schweiz Med Wschr 126:15–21
Karrer W, Rothe TB, Rycks A, Keller U (2000) Nasale CPAP-Therapie beim obstruktiven Schlafapnoe-Syndrom: Patienten-Compliance. Schweiz Med Wochenschr 130:1291–1297
Krieger J (1992) Long-term compliance with nasal continuous positive airway pressure (CPAP) in obstructive sleep apnea patients and nonapneic snorers. Sleep 15:42–46
Krieger J, Kurtz D, Petiau C, Sforza E, Trautmann D (1996) Long-term compliance with CPAP therapy in obstructive sleep apnea patients and in snorers. Sleep 19:136–143
Krieger J, Sforza E, Petiau C, Weiss T (1998) Simplified diagnostic procedure for obstructive sleep apnoea syndrome: lower subsequent compliance with CPAP. Eur Respir J 12:776–779
Mc Ardle N, Devereux G, Heidarnejad H, Engleman HM, Mackay TW, Douglas NJ (1999) Long-term use of CPAP therapy for sleep apnea / hypopnea syndrome. Am J Respir Crit Care Med 159:1108–1114
Meslier N, Lebrun T, Grillier-Lanoir V, Rolland N, Henderick C, Sailly JC, Racineux JL (1998) A French survey of 3225 patients treated with CPAP for obstructive sleep apnoea: benefits, tolerance, compliance and quality of life. Eur Respir J 12:185–192
Meurice JC, Dore P, Paquereau J, Neau JP, Ingrand P, Chavagnat JJ, Patte F (1994) Predictive factors of long-term compliance with nasal continuous positive airway pressure treatment in sleep apnea syndrome. Chest 105:429–433
Noseda A, Jann E, Hoffmann G, Linkowski P, Kerkhofs M (2000) Compliance with nasal continuous positive airway pressure assessed with a pressure monitor: pattern of use and influence of sleep habits. Respir Med 94:76–81
Orth M, Rasche K, Ullrich HU, Duchna HW, Schultze-Werninghaus G (1995) Langzeitakzeptanz der n-CPAP-Therapie bei Patienten mit schlafbezogenen Atmungsstörungen. Pneumologie 49:212–215
Pelletier-Fleury N, Rakotonanahary D, Fleury B (2001) The age and other factors in the evaluation of compliance with nasal continuous positive airway pressure for obstructive sleep apnea syndrome. A Cox’s proportional hazard analysis. Sleep Medicine 2:225–232
Pépin JL, Krieger J, Rodenstein D, Cornette A, Sforza E, Delguste P, Deschaux C, Grillier V, Lévy P (1999) Effective compliance during the first 3 months of continuous positive airway pressure. Am J Respir Crit Care Med 160:1124–1129
Pépin JL, Leger P, Veale D, Langevin B, Robert D, Lévy P (1995) Side effects of nasal continuous positive airway pressure in sleep apnea syndrome. Study of 193 patients in two French sleep centers. Chest 107:375–381
Pieters Th, Collard Ph, Aubert G, Dury M, Delguste P, Rodenstein DO (1996) Acceptance and long-term compliance with nCPAP in patients with obstructive sleep apnoea syndrome. Eur Respir J 9:939–944
Popescu G, Latham M, Allgar V, Elliott MW (2001) Continuous positive airway pressure for sleep apnoea/hypopnoea syndrome: usefulness of a 2 week trial to identify factors associated with long term use. Thorax 56:727–733
Rauscher H, Formanek D, Popp W, Twick H (1993) Self-reported vs measured compliance with nasal CPAP for obstructive sleep apnea. Chest 103:1675–1680
Reeves-Hoché MK, Meck R, Zwillich CW (1994) Nasal CPAP: an objective evaluation of patient compliance. Am J Respir Crit Care Med 149:149–154
Richard W, Venker J, den Herder C, Kox D, van den Berg B, Laman M, van Tinteren H, de Vries N (2007) Acceptance and long-term compliance of nCPAP in obstructive sleep apnea. Eur Arch Otorhinolaryngol 264:1081–1086
Russo-Magno P, O’Brien A, Panciera T, Rounds S (2001) Compliance with CPAP therapy in older men with obstructive sleep apnea. JAGS 49:1205–1211
Sanders MH, Gruendl CA, Rogers RM (1986) Patient compliance with nasal CPAP therapy for sleep apnea. Chest 90:330–333
Sin DD, Mayers I, Man GCW, Pawluk L (2002) Long-term compliance rates to continuous positive airway pressure in obstructive sleep apnea: a population-based study. Chest 121:430–435
Stepnowsky CJ, Dimsdale JE (2002) Dose-response relationship between CPAP compliance and measures of sleep apnea severity. Sleep Medicine 3:329–334
Sucena M, Liistro G, Aubert G, Rodenstein DO, Pieters T (2006) Continuous positive airway pressure treatment for sleep apnoea: compliance increases with time in continuing users. Eur Respir J 27:761–766
Waldhorn RE, Herrick TW, Nguyen MC, O’Donnell AE, Sodero J, Potolicchio SJ (1990) Long-term compliance with nasal continuous positive airway pressure therapy of obstructive sleep apnea. Chest 97:33–38
Wild MR, Engleman HM, Douglas NJ, Espie CA (2004) Can psychological factors help us to determine adherence to CPAP? A prospective study. Eur Respir J 24:461–465
Wenzel M, Neifer C, Wenzel G, Kerl J, Jürgens K, Suchi S, Köhler D (2008) Poststationäre Nachsorge und probatorische CPAP-Therapie schlafbezogener obstruktiver Atemstörungen steigern die Langzeitcompliance. Pneumologie 62:75–79
De Zeeuw J, Baberg HAT, Duchna HW, Kempkens DJ, Walther JW, Schultze-Werninghaus G, Rasche K, Orth M (2007) Die Kontrollüberzeugung ist ein Prädiktor für CPAP-Compliance bei obstruktivem Schlafapnoe-Syndrom. Pneumologie 61:283–290
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Orth, M., Duchna, HW., Kotterba, S. et al. Langzeit-Compliance der CPAP-Therapie bei obstruktivem Schlafapnoe-Syndrom. Somnologie 12, 258–269 (2008). https://doi.org/10.1007/s11818-008-0361-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11818-008-0361-9