Experimental study on fire protection methods of reinforced concrete beams strengthened with carbon fiber reinforced polymer

  • Research Article
  • Published:
Frontiers of Architecture and Civil Engineering in China Aims and scope Submit manuscript

Abstract

In this paper, two reinforced concrete (RC) beams strengthened with carbon fiber reinforced polymer (CFRP) and attached with thick-painted fire resistant coating were tested for fire resistance following the standard fire testing procedures. The experimental results show that the specimen pasted with the insulated layer of 50 mm in thickness could resist fire for 2.5 h. It is also demonstrated that the steel wire mesh embedded in the insulated layer can effectively prevent it from cracking and eroding under firing.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Wu Bo, Wan Zhijun. Study on the strengths of CFS and adhesive at elevated temperatures. In: 3rd National Conference for Fire-resistance and Anti-corrosion of Steel Structures & 1st National Conference on Structural Fire-resistance. Fuzhou, 2005, 386–394 (in Chinese)

  2. Zeng Chunhua. Study of ultimate moment of reinforced concrete beams strengthened by Epoxy-bonded steel plates in high temperature. Dissertation for the Doctoral Degree. Nanjing: College of Civil Engineering, Southeast University, 2001 (in Chinese)

    Google Scholar 

  3. Tang Longgui. Anti-oxidation treatment on carbon fiber. Chemical Journal of Chinese Universities, 1995, 16(8): 1301 (in Chinese)

    Google Scholar 

  4. State Technical Research Centre for Diagnosing and Transforming Engineering of Industrial Buildings. Technical Specification for Strengthening Concrete Structure with Carbon Fiber Reinforced Polymer Laminate (CECS146: 2003). Beijing, 2002 (in Chinese)

  5. Shanghai Research Institute of Building Science. Technical Code for Strengthening Concrete Structures with Fiber Reinforced Polymer Laminate (DG/TJ 08-012-2002). Shanghai, 2002 (in Chinese)

  6. Williams B K, Kodur V K R, Bisby L A, et al. The Performance of FRP-strengthened concrete slabs in fire. In: 4th International Conference on Advanced Composite Materials in Bridges and Structures (ACMBS IV) (CD-ROM). Calgary, 2004

  7. Bisby L A, Kodur V K R, Green M F. Performance in fire of FRP-confined reinforced concrete columns. In: 4th International Conference on Advanced Composite Materials in Bridges and Structures (ACMBS IV) (CD-ROM). Calgary, 2004

  8. Xu Zhisheng, Feng Kai, Zhang Weizheng, et al. Experimental analysis of CFRP used to strengthen RC beam after fire. Journal of Harbin Institute of Technology, 2005, 37(1): 98–101 (in Chinese)

    Google Scholar 

  9. Tianjin Fire Research Institute of China Public Security. Fire-resistance Tests-elements of Building Construction (GB/T 9978-1999). Beijing: China Standard Press, 1999 (in Chinese)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hu Kexu.

Additional information

__________

Translated from Journal of Tongji University (Natural Sciences), 2006, 34(11): 1452–1456 [译自: 同济大学学报 (自然科学版)]

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hu, K., He, G. & Lu, F. Experimental study on fire protection methods of reinforced concrete beams strengthened with carbon fiber reinforced polymer. Front. Archit. Civ. Eng. China 1, 399–404 (2007). https://doi.org/10.1007/s11709-007-0054-7

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11709-007-0054-7

Keywords

Navigation