Summary
A number of methods have been developed to measure intracellular pH (pHi) because of its importance in intracellular events. A major advance in accurate pHi measurement was the development of the ratiometric fluorescent indicator dye, 2′,7′-bis(carboxyethyl)-5,6-carboxyfluorescein (BCECF). We have used a fluorescence multi-well plate reader and a ratiometric method for determining pHi in primary cultures of rabbit corneal epithelial (CE) cells with BCECF. Fluorescence was measured at excitation wavelengths of 485±11 nm and 395±12.5 nm, with emission detected at 530±15 nm. Cells grown in multi-well plates were loaded with 4 µM BCECF for 30 min at 37° C. Resting pHi was 7.34±0.03 (2 cultures, N=5 wells). Changes in pHi determined with the fluorescence multi-well plate reader after the addition and removal of NH4Cl or sodium lactate were comparable to changes in cells analyzed with a digitized fluorescence imaging system. A concentration-response relationship involving changes in pHi was easily demonstrated in CE cells after treatment with ionomycin, a calcium ionophore. Low doses of ionomycin (2.5–5 µM), produced a prolonged acidification; 7.5 µM ionomycin produced a transient acidification; and 10 µM ionomycin resulted in a slight alkalinization. We conclude that accurate pHi measurements can be obtained with a ratiometric method with BCECF in a multi-well plate reader. This technology may simplify screening studies evaluating effects of hormones, growth factors, or toxicants on pHi homeostasis.
Similar content being viewed by others
References
Bright, G. R.; Fisher, G. W.; Rogowska, J., et al. Fluorescence ratio imaging microscopy. Methods Cell Biol. 30:157–192; 1989.
Busa, W. B.; Nuccitelli, R. Metabolic regulation via intracellular pH. Am. J. Physiol. 246:R409-R438; 1984.
Grant, R. L.; Acosta, D. A rapid, accurate method to determine intracellular pH using a fluorescence multiplate reader. FASEB J. 8:A649; 1994.
Grant, R. L.; Acosta, D. Interactions of intracellular pH and intracellular calcium in primary cultures of rabbit corneal epithelial cells. In Vitro Cell. Dev. Biol. 32:38–45; 1996.
Grant, R. L.; Yao, C.; Gabaldon, D., et al. Evaluation of surfactant cytotoxicity potential by primary cultures of ocular tissues: I. Characterization of rabbit corneal epithelial cells and initial injury and delayed toxicity studies. Toxicology 76:153–176; 1992.
Mahnensmith, R. L.; Aronson, P. S. The plasma membrane sodium-hydrogen exchanger and its role in physiological and pathophysiological processes. Circulation Res. 56:773–788; 1985.
Rink, T. J.; Tsien, R. Y.; Pozzan, T. Cytoplasmic pH and free Mg2+ in lymphocytes. J. Cell. Biol. 95:189–196; 1982.
Roos, A.; Boron, W. F. Intracellular pH. Physiol. Rev. 61:296–434; 1981.
Slotki, I.; Schwartz, J. H.; Alexander, E. A. Interrelationship between cell pH and cell calcium in rat inner medullary collecting duct cells. Am. J. Physiol. 265:C432-C438; 1993.
Thomas, J. A.; Buchsbaum, R. N.; Zimniak, A., et al. Intracellular pH measurements in Ehrlich Ascites tumor cells utilizing spectroscopic probes generated in situ. Biochemistry 18:2210–2218; 1979.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Grant, R.L., Acosta, D. Ratiometric measurement of intracellular pH of cultured cells with BCECF in a fluorescence multi-well plate reader. In Vitro Cell.Dev.Biol.-Animal 33, 256–260 (1997). https://doi.org/10.1007/s11626-997-0044-z
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s11626-997-0044-z