Abstract
We report successful stent implantation and secondary coil embolization in a wide-necked dissecting aneurysm in the vertebral artery. Intravascular ultrasonography (IVUS) showed the thrombosed pseudolumen clearly and enabled precise determination of the appropriate stent size. After stent implantation, Guglielmi detachable coil embolization was performed. Further experience is necessary to refine the technique, but IVUS may be useful to improve the safety of stent-assisted embolization.
Similar content being viewed by others
References
J Rosenorn V Eskesen K Schmidt F Ronde (1987) ArticleTitleThe risk of rebleeding from ruptured intracranial aneurysms J Neurosurg 67 329–32 Occurrence Handle3612265 Occurrence Handle1:STN:280:DyaL2s3ot1Khug%3D%3D
TM Sundt SuffixJr (1977) ArticleTitleCerebral vasospasm following subarachnoid hemorrhage: evolution, management and relationship to timing of surgery Clin Neurosurg 24 228–39 Occurrence Handle583683
D Tettenborn J Dycka (1990) ArticleTitlePrevention and treatment of delayed ischemic dysfunction in patients with aneurismal subarachnoid hemorrhage Stroke 21 IssueIDSuppl 4 859
A Yamaura Y Watanabe N Saeki (1990) ArticleTitleDissecting aneurysms of the intracranial vertebral artery J Neurosurg 72 183–8 Occurrence Handle2404089 Occurrence Handle1:STN:280:DyaK3c7htFyhtQ%3D%3D
T Mizutani T Aruga T Kirino Y Miki I Saito T Tsuchida (1995) ArticleTitleRecurrent subarachnoid hemorrhage from untreated ruptured vertebrobasilar dissecting aneurysms Neurosurgery 36 905–13 Occurrence Handle7791980 Occurrence Handle1:STN:280:DyaK2Mzht1WqsQ%3D%3D
G Guglielmi F Vinuela J Dion G Duckwiler (1991) ArticleTitleElectro-thrombosis of saccular aneurysm via endovascular approach. Part 2. Preliminary clinical experience J Neurosurg 75 8–14 Occurrence Handle2045924 Occurrence Handle1:STN:280:DyaK3M3lvFamtQ%3D%3D
K Irie M Kawanishi A Shindo S Nagao (2002) ArticleTitleIntraaneurysmal embolization using Guglielmi detachable coils for cerebral aneurysms: selection of embolization technique related to the aneurysmal neck diameter Surg Cereb Stroke (Jpn) 30 198–203 Occurrence Handle10.2335/scs.30.198
C Cognard A Weil L Spelle M Piotin L Castaings A Rey et al. (1999) ArticleTitleLong-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils Radiology 212 348–56 Occurrence Handle10429689 Occurrence Handle1:STN:280:DyaK1MzlvVehsg%3D%3D
RA Melicle AK Wakhloo R Rodriguez LR Guterman LN Hopkins (1997) ArticleTitleTemporary balloon protection as an adjunct to endosaccular coiling of wide-necked cerebral aneurysm: technical note Neurosurgery 41 975–8 Occurrence Handle10.1097/00006123-199710000-00045
RT Higashida W Smith D Gress R Urwin CF Dowd PA Balousek et al. (1997) ArticleTitleIntravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery: case report and review of the literature J Neurosurg 87 944–9 Occurrence Handle9384409 Occurrence Handle1:STN:280:DyaK1c%2FksVSltw%3D%3D Occurrence Handle10.3171/jns.1997.87.6.0944
G Lanzino AK Wakhloo RD Fessler ML Hartney LR Guterman LN Hopkins (1999) ArticleTitleEfficacy and current limitations of intravascular stents for intracranial internal carotid, vertebral, and basilar artery aneurysms J Neurosurg 91 538–46 Occurrence Handle10507372 Occurrence Handle1:STN:280:DyaK1MvjsFajtA%3D%3D Occurrence Handle10.3171/jns.1999.91.4.0538
K Irie M Kawanishi S Nagao (2000) ArticleTitleCombined endovascular stent implantation and endovascular coil placement for treatment of a wide-necked vertebral artery aneurysm: a case report Jpn J Neurosurg (Tokyo) 9 696–701
K Satoh J Satomi S Matsubara S Nagahiro (1998) ArticleTitleMeasurement of volume ratio to predict coil compaction, on aneurysmal embolization Intervent Neuroradiol 4 IssueIDSuppl 1 179–82
S Tamatani Y Ito H Abe T Koike S Takeuchi R Tanaka (2002) ArticleTitleEvaluation of the stability of aneurysms after embolization using detachable coils: correlation between stability of aneurysmal and embolized volume of aneurysms AJNR Am J Neuroradiol 23 762–7 Occurrence Handle12006273
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Kono, A., Fukuda, T., Shibata, Y. et al. Usefulness of intravascular ultrasonography for treatment of a ruptured vertebral dissecting aneurysm. Radiat Med 24, 577–582 (2006). https://doi.org/10.1007/s11604-006-0065-7
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s11604-006-0065-7