Usefulness of intravascular ultrasonography for treatment of a ruptured vertebral dissecting aneurysm

  • CASE REPORT
  • Published:
Radiation Medicine Aims and scope Submit manuscript

Abstract

We report successful stent implantation and secondary coil embolization in a wide-necked dissecting aneurysm in the vertebral artery. Intravascular ultrasonography (IVUS) showed the thrombosed pseudolumen clearly and enabled precise determination of the appropriate stent size. After stent implantation, Guglielmi detachable coil embolization was performed. Further experience is necessary to refine the technique, but IVUS may be useful to improve the safety of stent-assisted embolization.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J Rosenorn V Eskesen K Schmidt F Ronde (1987) ArticleTitleThe risk of rebleeding from ruptured intracranial aneurysms J Neurosurg 67 329–32 Occurrence Handle3612265 Occurrence Handle1:STN:280:DyaL2s3ot1Khug%3D%3D

    PubMed  CAS  Google Scholar 

  2. TM Sundt SuffixJr (1977) ArticleTitleCerebral vasospasm following subarachnoid hemorrhage: evolution, management and relationship to timing of surgery Clin Neurosurg 24 228–39 Occurrence Handle583683

    PubMed  Google Scholar 

  3. D Tettenborn J Dycka (1990) ArticleTitlePrevention and treatment of delayed ischemic dysfunction in patients with aneurismal subarachnoid hemorrhage Stroke 21 IssueIDSuppl 4 859

    Google Scholar 

  4. A Yamaura Y Watanabe N Saeki (1990) ArticleTitleDissecting aneurysms of the intracranial vertebral artery J Neurosurg 72 183–8 Occurrence Handle2404089 Occurrence Handle1:STN:280:DyaK3c7htFyhtQ%3D%3D

    PubMed  CAS  Google Scholar 

  5. T Mizutani T Aruga T Kirino Y Miki I Saito T Tsuchida (1995) ArticleTitleRecurrent subarachnoid hemorrhage from untreated ruptured vertebrobasilar dissecting aneurysms Neurosurgery 36 905–13 Occurrence Handle7791980 Occurrence Handle1:STN:280:DyaK2Mzht1WqsQ%3D%3D

    PubMed  CAS  Google Scholar 

  6. G Guglielmi F Vinuela J Dion G Duckwiler (1991) ArticleTitleElectro-thrombosis of saccular aneurysm via endovascular approach. Part 2. Preliminary clinical experience J Neurosurg 75 8–14 Occurrence Handle2045924 Occurrence Handle1:STN:280:DyaK3M3lvFamtQ%3D%3D

    PubMed  CAS  Google Scholar 

  7. K Irie M Kawanishi A Shindo S Nagao (2002) ArticleTitleIntraaneurysmal embolization using Guglielmi detachable coils for cerebral aneurysms: selection of embolization technique related to the aneurysmal neck diameter Surg Cereb Stroke (Jpn) 30 198–203 Occurrence Handle10.2335/scs.30.198

    Article  Google Scholar 

  8. C Cognard A Weil L Spelle M Piotin L Castaings A Rey et al. (1999) ArticleTitleLong-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils Radiology 212 348–56 Occurrence Handle10429689 Occurrence Handle1:STN:280:DyaK1MzlvVehsg%3D%3D

    PubMed  CAS  Google Scholar 

  9. RA Melicle AK Wakhloo R Rodriguez LR Guterman LN Hopkins (1997) ArticleTitleTemporary balloon protection as an adjunct to endosaccular coiling of wide-necked cerebral aneurysm: technical note Neurosurgery 41 975–8 Occurrence Handle10.1097/00006123-199710000-00045

    Article  Google Scholar 

  10. RT Higashida W Smith D Gress R Urwin CF Dowd PA Balousek et al. (1997) ArticleTitleIntravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery: case report and review of the literature J Neurosurg 87 944–9 Occurrence Handle9384409 Occurrence Handle1:STN:280:DyaK1c%2FksVSltw%3D%3D Occurrence Handle10.3171/jns.1997.87.6.0944

    Article  PubMed  CAS  Google Scholar 

  11. G Lanzino AK Wakhloo RD Fessler ML Hartney LR Guterman LN Hopkins (1999) ArticleTitleEfficacy and current limitations of intravascular stents for intracranial internal carotid, vertebral, and basilar artery aneurysms J Neurosurg 91 538–46 Occurrence Handle10507372 Occurrence Handle1:STN:280:DyaK1MvjsFajtA%3D%3D Occurrence Handle10.3171/jns.1999.91.4.0538

    Article  PubMed  CAS  Google Scholar 

  12. K Irie M Kawanishi S Nagao (2000) ArticleTitleCombined endovascular stent implantation and endovascular coil placement for treatment of a wide-necked vertebral artery aneurysm: a case report Jpn J Neurosurg (Tokyo) 9 696–701

    Google Scholar 

  13. K Satoh J Satomi S Matsubara S Nagahiro (1998) ArticleTitleMeasurement of volume ratio to predict coil compaction, on aneurysmal embolization Intervent Neuroradiol 4 IssueIDSuppl 1 179–82

    Google Scholar 

  14. S Tamatani Y Ito H Abe T Koike S Takeuchi R Tanaka (2002) ArticleTitleEvaluation of the stability of aneurysms after embolization using detachable coils: correlation between stability of aneurysmal and embolized volume of aneurysms AJNR Am J Neuroradiol 23 762–7 Occurrence Handle12006273

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Atsushi K. Kono.

About this article

Cite this article

Kono, A., Fukuda, T., Shibata, Y. et al. Usefulness of intravascular ultrasonography for treatment of a ruptured vertebral dissecting aneurysm. Radiat Med 24, 577–582 (2006). https://doi.org/10.1007/s11604-006-0065-7

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11604-006-0065-7

Keywords

Navigation