Summary
The purpose of this study was to compare monotonic biomechanical properties of gourd-shaped LCP fixation with LCP fixation of human tibial shaft in gap fracture mode. Twenty paired fresh cadaveric human tibias were randomly divided into 4 groups (5 pairs each): (1) axial loading single cycle to failure testing, (2) torsion single cycle to failure testing, (3) 4-point bending single cycle to failure testing, and (4) dynamic 4-point bending testing. A 7-hole 4.5 mm gourd-shaped LCP was secured on the anteromedial surface of 1 randomly selected bone from each pair, respectively, using 6 locking screws in the 1st, 2nd, 3rd, 5th, 6th and 7th hole with the middle hole unfilled and just located at the mid-diaphysis of the tibia. A 7-hole 4.5 mm LCP was secured on the other bone with the same method. Standard AO/ASIF techniques were used. After fixation finished, a 10 mm gap in the mid-diaphysis of tibia was created, centrally located at the unfilled hole. The axial, torsional, and bending stiffness and failure strengths were calculated from the collected data in static testings and statistically compared using paired Student’s t-test. The 4-point bending fatigue lives of the two constructs were calculated from the dynamic testing data and also statistically compared using paired Student’s t-test. Failure modes were recorded and visually analyzed. P<0.05 was considered significant. Results showed that the axial, torsional and bending stiffness of gourd-shaped LCP construct was greater (4%, 19%, 12%, respectively, P<0.05) than that of the LCP construct, and the axial, torsional and bending failure strengths of gourd-shaped LCP construct were stronger (10%, 46%, 29%, respectively, P<0.05) than those of the LCP construct. Both constructs failed as a result of plate plastic torsional deformation. After axial loading and 4-point bending testings, LCP failed in term of an obvious deformation of bent apex just at the unfilled plate hole, while the gourd-shaped LCP failed in term of a deformation of bent arc between the 3rd and 5th holes, which indicated a more consistent stress distribution on gourd-shaped LCP. Fatigue life of gourd-shaped LCP construct was significantly greater than LCP construct (153 836±2 228 vs. 132 471±6 460 cycles, P<0.01). All constructs failed as a result of fracture of the plate through the compression hole of the unfilled combination screw hole. The biomechanical testing showed that gourd-shaped LCP can provide greater stiffness and strength, and longer fatigue life than LCP. The gourd-shaped LCP may be more advantageous mechanically and may reduce the plate breakage rate clinically.
Similar content being viewed by others
References
Frigg R. Locking compression plate (LCP). An osteosynthesis plate based on the dynamic compression plate and the point contact fixator (PC-Fix). Injury, 2001,32(Suppl 2):63–66
Wagner M, Frigg R. Locking compression plate (LCP): Ein neuer AO-Standard. OP J, 2000,16(3):238–243
Florin M, Arzdorf M, Linke B, et al. Assessment of stiffness and strength of 4 different implants available for equine fracture treatment: a study on a 20 degrees oblique long bone fracture model using a bone substitute. Vet Surg, 2005,34(3): 231–238
Sommer C, Gautier E, Müller M, et al. First clinical results of the locking compression plate (LCP). Injury, 2003,34(Suppl 2):43–54
Sommer C, Babst R, Müller M, et al. Locking compression plate loosening and plate breakage: a report of four cases. J Orthop Trauma, 2004,18(8):571–577
Green E, Lubahn JD, Evans J. Risk factors, treatment, and outcomes associated with nonunion of the midshaft humerus fracture. J Surg Orthop Adv, 2005,14(2):64–72
Gandhi A, Liporace F, Azad V, et al. Diabetic fracture healing. Foot Ankle Clin, 2006,11(4):805–824
Brunner H, Simpson JP. Fatigue fracture of bone plates. Injury, 1980,11(3):203–207
Vallier HA, Hennessey TA, Sontich JK, et al. Failure of LCP condylar plate fixation in the distal part of the femur: a report of six cases. J Bone Joint Surg [Am], 2006,88(4):846–853
Yukata K, Doi K, Hattori Y, et al. Early breakage of a titanium volar locking plate for fixation of a distal radius fracture: case report. J Hand Surg Am, 2009,34(5): 907–909
Cartner JL, Messina A, Baker C, et al. Does insertion torque affect the mechanics of locking hole inserts and fatigue performance of bridge plate constructs? Bone Joint Sci, 2011,2(3):1–4
Ruedi TP, Murphy WM. AO principles of fracture management. Stuttgart New York: Thieme Verlag, 2000,139–230
Ahmad M, Nanda R, Bajwa AS, et al. Biomechanical testing of the locking compression plate: when does the distance between bone and implant significantly reduce construct stability? Injury, 2007,38(3):358–364
Ozkaya N, Nordin M. Fundamentals of Biomechanics, Equilibrium, Motion, and Deformation. New York, NY, Van Nostrand Reinhold, 1991,277–278
Brinker WO, Olmstead ML, Sumner-Smith G, et al. Manual of Internal Fixation in Small Animals. 2nd ed. Berlin, Germany, Springer-Verlag, 1998,1–289
Scott P, Elizabeth G, Roberto E. Fatigue analysis of plates used for fracture stabilization in small dogs and cats. Vet Surg, 2006,35(6):573–578
Kanchanomai C, Phiphobmongkol V, Muanjan P. Fatigue failure of an orthopedic implant-A locking compression plate. Eng Failure Anal, 2008,15(5):521–530
Hoffmeier KL, Hofmann GO, Mückley T. Choosing a proper working length can improve the lifespan of locked plates: A biomechanical study. Clin Biomech (Bristol, Avon), 2011,26(4):405–409
Bellapianta J, Dow K, Pallotta NA, et al. Threaded screw head inserts improve locking plate biomechanical properties. J Orthop Trauma, 2011,25(2):65–71
Dumbleton JH, Black J. Principles of mechanics. In: Black J, Dumbleton JH, eds. Clinical biomechanics: a case history approach. Churchill Livingstone, New York, 1981,359–400
Tencer AF, Johnson KD, Kyle RF, et al. Biomechanics of fractures and fracture fixation. Instr Course Lect, 1993,42:19–55
Seide K, Triebe J, Faschingbauer M. Locked vs. unlocked plate osteosynthesis of the proximal humerus-a biomechanical study. Clin Biomech (Bristol, Avon), 2007,22(2): 176–182
Roe S. Internal Fracture Fixation: Textbook of Small Animal Surgery. 3rd ed. Philadelphia, PA, Saunders, 2003, 1798–1881
Sod GA. Numerical Methods in Fluid Dynamics: Initial and Initial Boundary-value Problems. Cambridge, UK, Cambridge University Press, 1986,321
Perren SM. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg [Br], 2002,84(8):1093–1110
Egol KA, Kubiak EN, Fulkerson E, et al. Biomechanics of locked plates and screws. J Orthop Trauma, 2004,18(8):488–493
Perren SM. Backgrounds of the technology of internal fixators. Injury, 2003,34(Suppl 2):B1–B3
Giannoudis PV, Einhorn TA, Marsh D. Fracture healing: the diamond concept. Injury, 2007,38(Suppl 4):S3–S6
Epari DR, Kassi JP, Schell H, et al. Timely fracture-healing requires optimization of axial fixation stability. J Bone Joint Surg [Am], 2007,89(7):1575–1585
Firoozabadi R, McDonald E, Nguyen T-Q, et al. Does plugging unused combination screw holes improve the fatigue life of fixation with locking plates in comminuted supracondylar fractures of the femur? J Bone Joint Surg [Br], 2012,94(2):241–248
Wheeler KR, James LA. Fatigue behavior of type 316 stainless steel under simulated body conditions. J Biomed Mater Res, 1971,5(3):267–281
Brunner H, Simpson JP. Fatigue fracture of bone plates. Injury, 1980,11(3):203–207
Dawson DB, Pelloux RM. Corrosion fatigue crack growth of titanium alloys in aqueous environments. Metallurg Trans, 1974,5(3):723–731
Author information
Authors and Affiliations
Corresponding author
Additional information
This project was supported by the National High Technology Research and Development Program of China (863 Program) (No. 2004AA421024).
Rights and permissions
About this article
Cite this article
Xu, Gh., Liu, B., Zhang, Q. et al. Biomechanical comparison of gourd-shaped LCP versus LCP for fixation of comminuted tibial shaft fracture. J. Huazhong Univ. Sci. Technol. [Med. Sci.] 33, 250–257 (2013). https://doi.org/10.1007/s11596-013-1106-y
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11596-013-1106-y