Abstract
Background
Open reduction internal fixation (ORIF) of distal radius fractures via a volar approach involves surgical release of the overlying pronator quadratus (PQ) muscle. Complete repair of the PQ, defined as full and stable replacement of the periphery of the PQ back to its original anatomic location, is not always possible upon conclusion of the operation. Postoperative consequences of incomplete PQ repair with regards to range of motion (ROM), grip strength, and complications are not well documented. It was hypothesized that the completeness of PQ repair would yield no significant difference in the postoperative ROM, grip strength, and incidence of complications.
Methods
A retrospective review was performed of 110 repairs of distal radius fractures with ORIF via placement of a volar locking plate. The following clinical data were extracted: complete or incomplete PQ repair, patient age, gender, follow-up ROM/grip strength, and incidence of postoperative complications.
Results and conclusions
No significant difference in ROM, grip strength, and postoperative complications was detected between the complete and incomplete PQ repair groups. Complications consisted of two incidences of malunion requiring revision surgery and one occurrence of complex regional pain syndrome. There were no tendon ruptures. No statistical difference in ROM/grip strength or incidence of postoperative complications was detected between the complete and incomplete PQ repair groups. Regardless of the level of injury sustained by the PQ, surgeons should make an effort to cover the distal aspect of the volar plate during closure following distal radius fracture ORIF. Coverage of the distal aspect of the plate with the PQ (at a minimum) provides adequate results in ROM and grip strength, as well as protection against flexor tendon injury.
Level of evidence
Therapeutic Level III: Retrospective Comparative Study.
Similar content being viewed by others
References
Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma. 2007;21:316–22.
Ateschrang A, Stuby F, Werdin F, Schaller HE, Weise K, Albrecht D. Flexor tendon irritations after locked plate fixation of the distal radius with the 3.5 mm T-plate identification of risk factors. Z Orthop Unfall. 2010;148:319–25.
Bell JS, Wollstein R, Citron ND. Rupture of flexor pollicis longus tendon: a complication of volar plating of the distal radius. J Bone Joint Surg Br. 1998;80:225–6.
Berglund LM, Messer TM. Complications of volar plate fixation for managing distal radius fractures. J Am Acad Orthop Surg. 2009;17:369–77.
Chung KC, Petruska EA. Treatment of unstable distal radial fractures with the volar locking plating system. Surgical technique. J Bone Joint Surg Br. 2007;89(Suppl 2 Pt.2):256–66. doi:10.2106/JBJS.G.00283.
Chung KC, Spilson SV. The frequency and epidemiology of hand and forearm fractures in the United States. J Hand Surg [Am]. 2001;26:908–15.
Davis DI, Baratz M. Soft tissue complications of distal radius fractures. Hand Clin. 2010;26:229–35.
Dos Remedios C, Nebout J, Benlarbi H, Caremier J, Sam-Wing JF, Beya R. Pronator quadratus preservation for distal radius fractures with locking palmar plate osteosynthesis. Surgical technique. Chir Main. 2009;28:224–9.
Drobetz H, Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop. 2003;27:1–6.
Johnson RK, Shrewsbury MM. The pronator quadratus in motions and in stabilization of the radius and ulna at the distal radioulnar joint. J Hand Surg [Am]. 1976;1:205–9.
Lattmann T, Dietrich M, Meier C, Kilgus M, Platz A. Comparison of two surgical approaches for volar locking plate osteosynthesis of the distal radius. J Hand Surg [Am]. 2008;33:1135–43.
McConkey MO, Schwab TD, Travlos A, Oxland TR, Goetz T. Quantification of pronator quadratus contribution to isometric pronation torque of the forearm. J Hand Surg Am. 2009;34:1612–7.
Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg [Am]. 2006;31:359–65.
Rozental TD, Blazar PE, Franko OI, Chacko AT, Earp BE, Day CS. Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation. A prospective randomized trial. J Bone Joint Surg Am. 2009;91:1837–46.
Soong M, Earp BE, Bishop G, Leung A, Blazar P. Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am. 2011;93:328–35.
Stuart PR. Pronator quadratus revisited. J Hand Surg [Br]. 1996;21:714–22.
Yao J, Skirven R, Osterman AL, Culp RW. Chapter 5: clinical assessment of the wrist. The wrist: diagnosis and operative treatment. 2nd edition. 2010. 119-150.
Acknowledgments
We would like to thank Mary Ann Cladis of Indiana University School of Medicine for her assistance in editing the manuscript.
Conflict of interest
The authors have no financial disclosures related to this article.
Source of funding
No external source was involved in funding this study.
Author information
Authors and Affiliations
Corresponding author
Additional information
Work was performed at the Stanford University Medical Center, Stanford, CA, USA.
About this article
Cite this article
Ahsan, Z.S., Yao, J. The importance of pronator quadratus repair in the treatment of distal radius fractures with volar plating. HAND 7, 276–280 (2012). https://doi.org/10.1007/s11552-012-9420-6
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11552-012-9420-6