Abstract
The use of computed tomography (CT) to triage suspected scaphoid fractures is appealing because it is more readily available and less expensive than magnetic resonance imaging (MRI). Twenty-eight patients with suspected scaphoid fractures (defined as tenderness in the area of the scaphoid and initial scaphoid-specific radiographs interpreted as normal) were enrolled in a prospective protocol evaluating triage with CT. Twenty patients reached an endpoint consisting of either (1) identification of a fracture accounting for the patient’s symptoms on CT or (2) normal radiographs 6 weeks or more from the time of injury. Only 2 of 28 patients (7%) were diagnosed with a nondisplaced fracture of the scaphoid waist. CT revealed an avulsion fracture of the distal pole of the scaphoid in two patients, nondisplaced fractures of the distal radius in six patients, and nondisplaced fractures of other carpal bones in four patients. Radiographs of the scaphoid taken 6 weeks or greater from the time of injury were interpreted as normal in the six patients with normal CT scans that completed the study. True scaphoid waist fractures are uncommon among patients with suspected scaphoid fractures. CT scans are useful for triage of suspected scaphoid waist fractures because alternative, less-troublesome fractures were identified in 43% of patients and no fractures were missed or undertreated. Immediate triage of suspected scaphoid fractures using CT in the emergency room has the potential to reduce unnecessary immobilization and diminish overall costs associated with treatment.
Similar content being viewed by others
References
Adey L, Souer JS, Lozano-Calderon S, Palmer W, Lee SG, Ring D. Computed tomography of suspected scaphoid fractures. J Hand Surg [Am] 2007;32(1):61–6.
Amadio PC. Scaphoid fractures. Orthop Clin North Am 1992;23(1):7–17.
Beeres FJ, Hogervorst M, Hollander P, Rhemrev S. Outcome of routine bone scintigraphy in suspected scaphoid fractures. Injury 2005;36(10):1233–6.
Bhat M, McCarthy M, Davis TR, Oni JA, Dawson S. MRI and plain radiography in the assessment of displaced fractures of the waist of the carpal scaphoid. J Bone Jt Surg Br 2004;86(5):705–13.
Brydie A, Raby N. Early MRI in the management of clinical scaphoid fracture. Br J Radiol 2003;76(905):296–300.
Chen S. The scaphoid compression test. J Hand Surg [Br] 1989;14(3):323–5.
Clay NR, Dias JJ, Costigan PS, Gregg PJ, Barton NJ. Need the thumb be immobilised in scaphoid fractures? A randomised prospective trial. J Bone Jt Surg Br 1991;73(5):828–32.
Dias JJ, Brenkel IJ, Finlay DB. Patterns of union in fractures of the waist of the scaphoid. J Bone Jt Surg Br 1989;71(2):307–10.
Dias JJ, Thompson J, Barton NJ, Gregg PJ. Suspected scaphoid fractures. The value of radiographs. J Bone Jt Surg Br 1990;72(1):98–101.
Dorsay TA, Major NM, Helms CA. Cost-effectiveness of immediate MR imaging versus traditional follow-up for revealing radiographically occult scaphoid fractures. AJR Am J Roentgenol 2001;177(6):1257–63.
Duppe H, Johnell O, Lundborg G, Karlsson M, Redlund-Johnell I. Long-term results of fracture of the scaphoid. A follow-up study of more than thirty years. J Bone Jt Surg Am 1994;76(2):249–52.
Foex B, Speake P, Body R. Best evidence topic report. Magnetic resonance imaging or bone scintigraphy in the diagnosis of plain x ray occult scaphoid fractures. Emerg Med J 2005;22(6):434–5.
Gaebler C, Kukla C, Breitenseher M, Trattnig S, Mittlboeck M, Vecsei V. Magnetic resonance imaging of occult scaphoid fractures. J Trauma 1996;41(1):73–6.
Gooding A, Coates M, Rothwell A. Cost analysis of traditional follow-up protocol versus MRI for radiographically occult scaphoid fractures: a pilot study for the Accident Compensation Corporation. N Z Med J 2004;117(1201):U1049.
Hambidge JE, Desai VV, Schranz PJ, Compson JP, Davis TR, Barton NJ. Acute fractures of the scaphoid. Treatment by cast immobilisation with the wrist in flexion or extension? J Bone Jt Surg Br 1999;81(1):91–2.
Hauger O, Bonnefoy O, Moinard M, Bersani D, Diard F. Occult fractures of the waist of the scaphoid: early diagnosis by high-spatial-resolution sonography. AJR Am J Roentgenol 2002;178(5):1239–45.
Hove LM. Epidemiology of scaphoid fractures in Bergen, Norway. Scand J Plast Reconstr Surg Hand Surg 1999;33(4):423–6.
Kumar S, O’Connor A, Despois M, Galloway H. Use of early magnetic resonance imaging in the diagnosis of occult scaphoid fractures: the CAST study (Canberra Area Scaphoid Trial). N Z Med J 2005;118(1209):U1296.
Larsen CF, Brondum V, Skov O. Epidemiology of scaphoid fractures in Odense, Denmark. Acta Orthop Scand 1992;63(2):216–8.
Memarsadeghi M, Breitenseher MJ, Schaefer-Prokop C, Weber M, Aldrian S, Gabler C, et al. Occult scaphoid fractures: comparison of multidetector CT and MR imaging—initial experience. Radiology. 2006;240(1):169–76.
Munk B, Frokjaer J, Larsen CF, Johannsen HG, Rasmussen LL, Edal A, et al. Diagnosis of scaphoid fractures. A prospective multicenter study of 1,052 patients with 160 fractures. Acta Orthop Scand 1995;66(4):359–60.
Phillips TG, Reibach AM, Slomiany WP. Diagnosis and management of scaphoid fractures. Am Fam Phys 2004;70(5):879–84.
Ring D, Jupiter JB, Herndon JH. Acute fractures of the scaphoid. J Am Acad Orthop Surg 2000;8(4):225–31.
Sanders WE. Evaluation of the humpback scaphoid by computed tomography in the longitudinal axial plane of the scaphoid. J Hand Surg [Am] 1988;13(2):182–7.
Sanders WE. Evaluation of the humpback scaphoid by computed tomography in the longitudinal axial plane of the scaphoid. J Hand Surg 1988;13:182–7.
Saxena P, McDonald R, Gull S, Hyder N. Diagnostic scanning for suspected scaphoid fractures: an economic evaluation based on cost-minimisation models. Injury 2003;34(7):503–11.
Senall JA, Failla JM, Bouffard JA, van Holsbeeck M. Ultrasound for the early diagnosis of clinically suspected scaphoid fracture. J Hand Surg [Am] 2004;29(3):400–5.
Staniforth P. Scaphoid fractures and wrist pain—time for new thinking. Injury 1991;22(6):435–6.
Tiel-van Buul MM, van Beek EJ, Borm JJ, Gubler FM, Broekhuizen AH, van Royen EA. The value of radiographs and bone scintigraphy in suspected scaphoid fracture. A statistical analysis. J Hand Surg [Br] 1993;18(3):403–6.
Acknowledgements
This study was supported by unrestricted research gifts from AO Foundation, Small Bone Innovations, Wright Medical, Smith and Nephew, and Biomet.
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Ty, J.M., Lozano-Calderon, S. & Ring, D. Computed Tomography for Triage of Suspected Scaphoid Fractures. HAND 3, 155–158 (2008). https://doi.org/10.1007/s11552-007-9077-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11552-007-9077-8