Extremely High Sensitive Plasmonic Refractive Index Sensors Based on Metallic Grating

  • Published:
Plasmonics Aims and scope Submit manuscript

Abstract

This work shows that a grating-based surface plasmon (SP) resonance sensing system can exhibit extremely high sensitivity to detect a small change of refractive index in an analyte. The corresponding sensitivity can be much higher than that of the prism-based systems. Both analytical calculation and rigorous coupled-wave analysis are used to study the angular sensitivity of the system. It is found that the system’s sensitivity can be over 600° per unit index change if (1) first-order diffracted wave is chosen to excite SP mode, (2) large SP resonant angles are used in the operation, and (3) grating filling factor is selected to be varied between 0.3 and 0.7. Furthermore, the sensing system has the best performance for detecting low-index analyte with a small change of refractive index.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Nylander C, Liedberg B, Lind T (1982) Gas detection by means of surface plasmons resonance. Sens Actuators 3:79–88

    Article  CAS  Google Scholar 

  2. Cullen DC, Brown RG, Lowe CR (1987) Detection of immuno-complex formation via surface plasmon resonance on gold-coated diffraction gratings. Biosensors 3(4):211–225

    Article  CAS  Google Scholar 

  3. Homola J, Yee SS, Gauglitz G (1999) Surface plasmon resonance sensors: review. Sens Actuators B 54:3–15

    Article  Google Scholar 

  4. Jory MJ, Vukusic PS, Sambles JR (1994) Development of a prototype gas sensor using surface plasmon resonance on gratings. Sens Actuators B 17:203–209

    Article  CAS  Google Scholar 

  5. Homola J, Koudela I, Yee SS (1999) Surface plasmon resonance sensors based on diffraction gratings and prism couplers: sensitivity comparison. Sens Actuators B 54:16–24

    Article  Google Scholar 

  6. Yoon KH, Shuler ML (2006) Design optimization of nano-grating surface plasmon resonance sensors. Opt Express 14(11):4842–4849

    Article  Google Scholar 

  7. Byun KM, Kim SJ, Kim D (2007) Grating-coupled transmission-type surface plasmon resonance sensors based on dielectric and metallic gratings. Appl Opt 46(23):5703–5708

    Article  Google Scholar 

  8. Cai DB, Lu YH, Lin KQ, Wang P, Ming H (2008) Improving the sensitivity of SPR sensors based on gratings by double-dips method (DDM). Opt Express 16(19):14597–14602

    Article  CAS  Google Scholar 

  9. Lin KQ, Lu YH, Chen JX, Zheng RS, Wang P, Ming H (2008) Surface plasmon resonance hydrogen sensor based on metallic grating with high sensitivity. Opt Express 16(23):18599–18604

    Article  CAS  Google Scholar 

  10. Yang XY, Xie WC, Liu DM (2008) Design of highly sensitive surface plasmon resonance sensors using planar metallic films closely coupled to nanogratings. Chin Phys Lett 25(1):148–151

    Article  CAS  Google Scholar 

  11. Li XF, Yu SF, Kumar A (2010) Excitation and optimization modeling of surface plasmon polaritons in a concentric circular metallic grating film. Plasmonics 5(1):69–74

    Article  CAS  Google Scholar 

  12. Palik EW (1985) Handbook of optical constants of solids. Academic, San Diego

    Google Scholar 

  13. Maier SA (2007) Plasmonics: fundamentals and applications. Springer, New York

    Google Scholar 

  14. Moharam MG, Gaylord TK (1986) Rigorous coupled-wave analysis of metallic surface-relief gratings. J Opt Soc Am A 3(11):1780–1787

    Article  CAS  Google Scholar 

  15. Li XF, Yu SF (2010) Diffraction characteristics of concentric circular metal grating operating within terahertz regime. IEEE J Quantum Electron 46(6):898–905

    Article  CAS  Google Scholar 

  16. Shankaran DR, Gobi KV, Sakai T, Matsumoto K, Toko K, Miura N (2005) Surface plasmon resonance immunosensor for highly sensitive detection of 2,4,6-trinitrotoluene. Biosens Bioelectron 20(9):1750–1756

    Article  CAS  Google Scholar 

Download references

Acknowledgment

The authors gratefully acknowledge the support of A*STAR SERC grant no. 082-101-0016.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to X. F. Li.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Li, X.F., Yu, S.F. Extremely High Sensitive Plasmonic Refractive Index Sensors Based on Metallic Grating. Plasmonics 5, 389–394 (2010). https://doi.org/10.1007/s11468-010-9155-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11468-010-9155-6

Keywords

Navigation