In this paper the reliability and performance of a vapour compression refrigeration system with ZnO nanoparticles in the working fluid was investigated experimentally. Nanorefrigerant was synthesized on the basis of the concept of the nanofluids, which was prepared by mixing ZnO nanoparticles with R152a refrigerant. The conventional refrigerant R134a has a global warming potential (GWP) of 1300 whereas R152a has a significant reduced value of GWP of 140 only. An experimental test rig is designed and fabricated indigenously in the laboratory to carry out the investigations. ZnO nanoparticles with refrigerant mixture were used in HFC R152a refrigeration system. The system performance with nanoparticles was then investigated. The concentration of nano ZnO ranges in the order of 0.1% v, 0.3% v and 0.5%v with particle size of 50 nm and 150 g of R152a was charged and tests were conducted. The compressor suction pressure, discharge pressure and evaporator temperature were measured. The results indicated that ZnO nanorefrigerant works normally and safely in the system. The ZnO nanoparticle concentration is an important factor considered for heat transfer enhancement in the refrigeration system. The performance of the system was significantly improved with 21% less energy consumption when 0.5%v ZnO-R152a refrigerant. Both the suction pressure and discharge pressure were lowered by 10.5% when nanorefrigerant was used. The evaporator temperature was reduced by 6% with the use of nanorefrigerant. Hence ZnO nanoparticles could be used in refrigeration system to considerably reduce energy consumption. The usage of R152a with zero ozone depleting potential (ODP) and very less GWP and thus provides a green and clean environment. The complete experimental results and their analysis are reported in the main paper.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Mohanraj M, Jayaraj S, Muraleedharan C, Chandrasekar P. Experimental investigation of R290/R600a mixture as an alternative to R134a in a domestic refrigerator. International Journal of Thermal Sciences, 2009, 48(5): 1036–1042

    Article  Google Scholar 

  2. Tsai W T. An overview of environmental hazards and exposure risk of hydrofluorocarbons (HFCs). Chemosphere, 2005, 61(11): 1539–1547

    Article  Google Scholar 

  3. Janseen M, Engles F. The use of HFC134a with mineral oil in hermetic cooling equipment, Report 95403/NO 07. Presented in the 19th International Congress of Refrigeration. The Hague 1995

    Google Scholar 

  4. Sekhar S J, Lal D M. HFC 134a/HC600a/HC290 mixture a retrofit for CFC12 systems. International Journal of Refrigeration, 2005, 28(5): 735–743

    Article  Google Scholar 

  5. Mahbubul I M, Fadhilah S A, Saidur R, Leong K Y, Amalina M A. Thermophysical properties and heat transfer, Performance of Al2O3/R-134a nanorefrigerants. International Journal of Heat and Mass Transfer, 2013, 57(1): 100–108

    Article  Google Scholar 

  6. Wongwises S, Chimres N. Experimental studies of hydrocarbon mixture to replace HFC134a in a domestic refrigerator. Energy Conversion and Management, 2005, 46(1): 85–100

    Article  Google Scholar 

  7. Bolaji B O, Akintunde M A, Falade T O. Comparative analysis of performance of three ozone-friends HFC refrigerants in a vapour compression refrigeration. Journal of Sustainable and Environment, 2011, 2: 61–64

    Google Scholar 

  8. Aminfar H, Haghgoo M R. Brownian motion and thermophoresis effects on natural convection of alumina-water nanofluid. Proceedings of the Institution of Mechanical Engineers. Part C, Journal of Mechanical Engineering Science, 2013, 227(1): 100–110

    Article  Google Scholar 

  9. Sarkar J, Bhattacharya S, Lal A. Selection of suitable natural refrigerants pairs for cascade refrigeration system. Proceedings of the Institution of Mechanical Engineers. Part A, Journal of Power and Energy, 2013, 227(5): 612–622

    Article  Google Scholar 

  10. Aminfar H, Maroofiazar R. A numerical study of the hydro-thermal behavior of nanofluids in rectangular microchannels using a mixture model. Proceedings of the Institution of Mechanical Engineers Part C: Journal of Mechanical Engineering Science, 2011, 225(4): 791–798

    Google Scholar 

  11. Tajik B, Abbassi A, Saffsr-Avval M, Najafabadi M A. Ultrasonic properties of suspensions of TiO2 and Al2O3 nanoparticles in water. Powder Technology, 2012, 217: 171–176

    Article  Google Scholar 

  12. Liu Z H, Zhu Q Z. Application of aqueous nanofluids in a horizontal mesh heat pipe. Energy Conversion and Management, 2011, 52(1): 292–300

    Article  Google Scholar 

  13. Tsai C Y, Chien H T, Ding P P, Chan B, Luh T Y, Chen P H. Effect of structural character of gold nanoparticles in nanofluid on heat pipe thermal performance. Materials Letters, 2004, 58(9): 1461–1465

    Article  Google Scholar 

  14. Salehi H, Zeinali Heris S, Noie S H. Zeinali Heris S, Noie SH. Water-silver nanofluid application in a TPCT under an external magnetic field. Heat Transfer Asian Research, 2012, 41(4): 289–301

    Article  Google Scholar 

  15. Arora A, Sachdev H L. Thermodynamic analysis of R422 series refrigerants as alternative refrigerants to HCFC22 in a vapour compression refrigeration system. International Journal of Energy Research, 2009, 33(8): 753–765

    Article  Google Scholar 

  16. Mittal N, Manoj V., Santhosh Kumar D., Satheesh A. Numerical simulation of mixed convection in a porous medium filled with water/Al2O3 Nanofluid. Heat Transfer-Asian Research, 2013, 42(1): 46–59

    Article  Google Scholar 

  17. He Z, Wang S, Wang X, Iqbal Z. Hydrogen storage in hierarchical nanoporous silicon-carbon nanotube architectures. International Journal of Energy Research, 2013, 37(7): 754–760

    Article  Google Scholar 

  18. Liu Z H, Li Y Y, Bao R. Composite effect of nanoparticle parameter on thermal performance of cylindrical micro-grooved heat pipe using nanofluids. International Journal of Thermal Sciences, 2011, 50: 558–568

    Article  Google Scholar 

  19. Mwaba M G, Huang X, Gu J. Influence of wick characteristics on heat pipe performance. International Journal of Energy Research, 2006, 30(7): 489–499

    Article  Google Scholar 

  20. Tsai C Y, Chien H T, Ding P P, Chan B, Luh T Y, Chen P H. Effect of structural character of gold nanoparticles in nanofluid on heat pipe thermal performance. Materials Letters, 2004, 58(9): 1461–1465

    Article  Google Scholar 

  21. Manimaran R, Palaniradja K, Algumurthi N, Hussain J. Experimental comparative study of heat pipe performance using CuO and TiO2 nanofluids. International Journal of Energy Research, 2013 Jun 6 [Epub ahead of print]

    Google Scholar 

  22. Bi S, Guo K, Liu Z, Wu J. Performance of a domestic refrigerator using TiO2-R600a nano-refrigerant as working fluid. Int J of Energy Conservation and Management, 2011, 52(1): 733–737

    Article  Google Scholar 

  23. Saidur R, Kazi S N, Hossain M S, Rahman M M, Mohammed H A. A review on the performance of nano-particles suspended with refrigerants and lubricating oils in refrigeration system. Renewable and Sustainable Energy Reviews, 2011, 15(1): 310–323

    Article  Google Scholar 

  24. Joseph Sekher S, Mohan Lal D, Renganarayanan S. Improved energy efficiency for CFC domestic refrigerators retrofitted with ozone friendly HFC134a. International Journal of Thermal Sciences, 2004, 43(3): 307–314

    Article  Google Scholar 

  25. Sendil Kumar D, Elansezhain R. Experimental study of Al2O3-R134a nano-refrigerant in refrigeration system. International Journal of Modern Engineering Research, 2012, 2(5): 3927–3929

    Google Scholar 

  26. Puliti G, Paoluccci S, Sen M. Thermodynamic properies of goldwater nanofluids using molecular dynamics. Journal of Nanoparticle Research, 2012, 14(12): 1296

    Article  Google Scholar 

  27. Yang K S, Chang W R, Chen I Y, Wang C C. An investigation of a top-mounted domestic refrigerator. Energy Conservation and Management, 2010, 51(7): 1422–1427

    Article  Google Scholar 

  28. Jiang W, Ding G, Peng H. Measurement and model on thermal conductivities of carbon nanotube nanorefrigerants. International Journal of Thermal Sciences, 2009, 48(6): 1108–1115

    Article  Google Scholar 

  29. Saidur R, Kazi S N, Hossain M S, Rahman M M, Mohamed H A. A review on the performance of nanoparticles suspended with refrigerants and lubricating oils in refrigeration systems. Renewable & Sustainable Energy Reviews, 2011, 15(1): 310–323

    Article  Google Scholar 

  30. Bolaji B O. Experimental study of R152a and R32 to replace R134a in a domestic refrigerator. Energy, 2010, 35(9): 3793–3798

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to D. Sendil Kumar or R. Elansezhian.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sendil Kumar, D., Elansezhian, R. ZnO nanorefrigerant in R152a refrigeration system for energy conservation and green environment. Front. Mech. Eng. 9, 75–80 (2014). https://doi.org/10.1007/s11465-014-0285-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11465-014-0285-y

Keywords

Navigation