Abstract
Bioaerosol charge information is of vital importance for their electrostatic collection. Here, electrostatic means and molecular tools were applied to studying bioaerosol charge dynamics. Positively or negatively charged bioaerosols were collected using an electrostatic sampler operated with a field strength of 1.1 kV cm−1 at a flow rate of 3 L min−1 for 40 min. Those with fewer or no charges bypassing the sampler were also collected using a filter at the downstream of the electrostatic sampler in one environment. The experiments were independently conducted three times in three different environments. The collected bacterial aerosols were cultured directly on agar plates at 26°C, and the colony forming units (CFU) were manually counted. In addition, the CFUs were washed off from the agar plates, and further subjected to polymerase chain reaction (PCR) and denaturing gradient gel electrophoresis (DGGE) for culturable diversity analysis. The results revealed remarkable differences in positively and negatively charged culturable bacterial aerosol concentration and diversity among the studied environments. In the office environment, negatively charged culturable bacterial aerosols appeared to dominate (P = 0.0489), while in outdoor and hotel environments both polarities had similar concentration levels (P = 0.078, P = 0.88, respectively). DGGE patterns for positively charged culturable bacterial aerosols were shown strikingly different from those of negatively charged regardless of the sampling environments. In addition, for each of the environments positively charged culturable bacterial aerosols collected were found to have more band pattern similarity with those positively charged for respective regions of agar plates than those negatively charged, and vice versa. The information developed here is useful for developing efficient electrostatic sampling protocols for bioaerosols.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Douwes J, Thorne P, Pearce N, et al. Bioaerosol health effects and exposure assessment: Progress and prospects. Ann Occup Hyg, 2003, 47: 187–200
Walinder R, Norback D, Wessen B, et al. Nasal lavage biomarkers: Effects of water damage and microbial growth in an office building. Arch Environ Occup Health, 2001, 56: 30–36
Laumbach R J, Kipen H M. Bioaerosols and sick building syndrome: Particles, inflammation, and allergy. Curr Opin Allergy Clin Immunol, 2005, 5: 135–139
Tolchinsky A D, Sigaev V I, Sigaev G I V, et al. Development of a personal bioaerosol sampler based on a conical cyclone with recirculating liquid film. J Occup Environ Hyg, 2010, 7: 156–162
Haatainen S, Laitinen J, Linnainmaa M, et al. The suitability of the IOM foam sampler for bioaerosol sampling in occupational environments. J Occup Environ Hyg, 2010, 7: 1–6
Bundke U, Reimann B, Nillius B, et al. Development of a bioaerosol single particle detector (BIO IN) for the fast Ice nucleus chamber FINCH. Atmos Meas Tech, 2010, 3: 263–271
Park D, Kim Y H, Park C W, et al. New bio-aerosol collector using a micromachined virtual impactor. J Aerosol Sci, 2009, 40: 415–422
Chen B T, Feather G A, Maynard A, et al. Development of a personal sampler for collecting fungal spores. Aerosol Sci Tech, 2004, 38: 926–937
Tan M, Shen F, Yao M, et al. Development of an automated electrostatic sampler (AES) for bioaerosol sensing. Aerosol Sci Tech, 2011, 45: 1154–1160
Xie C, Shen F, Yao M. A novel method for measuring the charge distribution of airborne microbes. Aerobiologia, 2011, 27: 135–145
Han T, Mainelis G. Design and development of an electrostatic sampler for bioaerosols with high concentration rate. J Aerosol Sci, 2008, 39: 1066–1078
Yao M, Zhang H, Dong S, et al. Comparison of electrostatic collection and liquid impinging methods when collecting airborne house dust allergens, endotoxin and (1,3)-β-D-glucans. J Aerosol Sci, 2009, 40: 492–502
Han T, An H R, Mainelis G. Performance of an electrostatic precipitator with superhydrophobic surface when collecting airborne bacteria. Aerosol Sci Tech, 2010, 44: 339–348
Madsen A M, Sharma A K. Sampling of high amounts of bioaerosols using a high-volume electrostatic field sampler. Ann Occup Hyg, 2008, 52: 167–176
Yao M, Mainelis G. Utilization of natural electrical charges on airborne microorganisms for their collection by electrostatic means. J Aerosol Sci, 2006, 37: 513–527
Mainelis G, Grinshpun S A, Willeke K, et al. Collection of airborne microorganisms by electrostatic precipitation. Aerosol Sci Tech, 1999, 30: 127–144
Mainelis G, Adhikari A, Willeke K, et al. Collection of airborne microorganisms by a new electrostatic precipitator. J Aerosol Sci, 2002, 33: 1417–1432
Mainelis G, Willeke K, Baron P, et al. Electrical charges on airborne microorganisms. J Aerosol Sci, 2001, 32: 1087–1110
Lee S A, Willeke K, Mainelis G, et al. Assessment of electrical charge on airborne microorganisms by a new bioaerosol sampling method. J Occup Environ Hyg, 2004, 1: 127–138
Melandri C, Prodi V, Tarroni G, et al. On the deposition of unipolarly charged particles in the human respiratory tract. In: Walton W H, ed. Inhaled Particles, No. 4. Oxford: Pergamon, 1977. 193–201
Vincent J H, Johnston W B, Jones A D, et al. Static electrification of airborne asbestos: A study of its causes, assessment and effects on deposition in the lungs of rats. Am Ind Hyg Assoc J, 1981, 42: 711–721
Prodi V, Mullaroni A. Electrostatic lung deposition experiments with humans and animals. Ann Occup Hyg, 1985, 29: 229–240
Bailey A G. The inhalation and deposition of charged particles within the human lung. J Electrostat, 1997, 42: 25–32
Grinshpun S A, Adhikari A, Honda T, et al. Control of aerosol contaminants in indoor air: Combining the particle concentration reduction with microbial inactivation. Environ Sci Technol, 2007, 41: 606–612
Li C S, Wen Y M. Control effectiveness of electrostatic precipitation on airborne microorganisms. Aerosol Sci Technol, 2003, 37: 933–938
Yao M, Mainelis G, An H R. Inactivation of microorganisms using electrostatic fields. Environ Sci Technol, 2005, 39: 3338–3344
Hogan C, Lee M H, Biswas P. Capture of viral particles in soft X-ray-enhanced corona systems: Charge distribution and transport characteristics. Aerosol Sci Technol, 2004, 38: 475–486
Shen F, Tan M, Xu H, et al. Development of a novel conductance-based technology for environmental bacterial sensing. Chin Sci Bull, 2013, 58: 440–448
Fierer N, Liu Z, Rodríguez-Hernández M, et al. Short-term temporal variability in airborne bacterial and fungal populations. Appl Environ Microbiol, 2008, 74: 200–207
Shelton B G, Kirkland K H, Flanders W D, et al. Profiles of airborne fungi in buildings and outdoor environments in the united states. Appli Environ Microbiol, 2002, 68: 1743–1753
Lee T, Grinshpun S A, Martuzevicius D, et al. Culturability and concentration of indoor and outdoor airborne fungi in six single-family homes. Atmos Environ, 2006, 40: 2902–2910
Brodie E L, DeSantis T Z, Parker J P M, et al. Urban aerosols harbor diverse and dynamic bacterial populations. Proc Natl Acad Sci USA, 2007, 104: 299–304
Muyzer G, de Waal E C, Uitterlinden A G. Profiling of complex microbial populations by denaturing gradient gel electrophoresis analysis of polymerase chain reaction-amplified genes coding for 16S rRNA. Appl Environ Microbiol, 1993, 59: 695–700
Maron P A, Lejon D P H, Carvalho E, et al. Assessing genetic structure and diversity of airborne bacterial communities by DNA fingerprinting and 16S rDNA clone library. Atmos Environ, 2005, 39: 3687–3695
Bowers R M, Lauber C L, Wiedinmyer C, et al. Characterization of airborne microbial communities at a high-elevation site and their potential to act as atmospheric ice nuclei. Appl Environ Microbiol, 2009, 75: 5121–5130
Yang L. Electrical impedance spectroscopy for detection of bacterial cells in suspensions using interdigitated microelectrodes. Talanta, 2008, 74: 1621–1629
Author information
Authors and Affiliations
Corresponding author
Additional information
This article is published with open access at Springerlink.com
Electronic supplementary material
Rights and permissions
This article is published under an open access license. Please check the 'Copyright Information' section either on this page or in the PDF for details of this license and what re-use is permitted. If your intended use exceeds what is permitted by the license or if you are unable to locate the licence and re-use information, please contact the Rights and Permissions team.
About this article
Cite this article
Shen, F., Kai, W. & Yao, M. Negatively and positively charged bacterial aerosol concentration and diversity in natural environments. Chin. Sci. Bull. 58, 3169–3176 (2013). https://doi.org/10.1007/s11434-013-5852-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11434-013-5852-9