Abstract
Local cerebral metabolic rate of glucose (LCMRGlc) is an important index for the description of neural function. Dynamic 18F-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) has been used for quantitative imaging of LCMRGlc in humans, but is seldom used routinely because of the difficulty in obtaining the input function noninvasively. A reference tissue-based Patlak plot model (rPatlak) was proposed to generate parametric images of LCMRGlc in a quantitative dynamic FDG-PET study without requiring blood sampling. Dynamic emission scans (4×0.5, 4×2 and 10×5 min) were acquired simultaneously with an IV bolus injection of 155 MBq of FDG. Arterial blood samples were collected during the scans via a catheter placed in the radial artery. Simulation data were also generated using the same scan sequence. The last ten scan data sets were used in a graphical analysis using the Patlak plot. The ratio of LCMRGlc estimated from the original Patlak (oPatlak, using plasma input) was used as the gold standard, and the standardized uptake value ratio (SUVR) was also calculated for comparison. Eight different tissues including white matter, gray matter, and whole brain were chosen as reference tissues for evaluation. Regardless of the reference region used, the slopes in the linear regression between oPatlak and rPatlak were closer to unity than the regression slopes between oPatlak and SUVR. The intercepts for the former were also closer to 0 than those for the latter case. The squared correlation coefficients were close to 1.0 for both cases. This showed that the results of rPatlak were in good agreement with those of oPatlak, however, SUVR exhibited more deviation. The simulation study also showed that the relative variance and bias for rPatlak were less than those for SUVR. The images obtained with rPatlak were very similar to those obtained with oPatlak, while there were differences in the relative spatial distribution between the images of SUVR and oPatlak. This study validates that the rPatlak method is better than the SUVR method and is a good approximation to the oPatlak method. The new method is suitable for generating LCMRGlc parametric images noninvasively.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Phelps M, Huang S C Hoffman E, et al. Tomographic measurement of local cerebral glucose metabolic rate in humans with F-18-2-fluoro-2-deoxy-D-glucose: Validation of method. Ann Neurol, 1979, 6: 371–388
Reivich M, Kuhl D, Wolf A J, et al. The 18-F-fluorodeoxyglucose method for the measurement of local cerebral glucose metabolism in man. Circ Res, 1979, 44: 127–137
Huang S C Phelps M, Hoffman E, et al. Noninvasive determination of local cerebral metabolic rate of glucose in man. Amer J Physiol, 1980, 238: E69–E82
Weinberg I N Huang S C Hoffman E J, et al. Validation of PET-acquired input functions for cardiac studies. J Nucl Med, 1988, 29: 241–247
Gambhir S S Schwaiger M, Huang S C, et al. Simple noninvasive quantification method for measuring myocardial glucose utilization in humans employing positron emission tomography and fluorine-18 deoxyglucose. J Nucl Med, 1989, 30: 359–366
Iida H, Rhodes C G de Silva R, et al. Use of the left ventricular time activity curve as a noninvasive input function in dynamic oxygen-15 water positron emission tomography. J Nucl Med, 1992, 33: 1669–1677
Germano G, Chen B C Huang S C, et al. Use of the abdominal aorta for arterial input function determination in hepatic and renal PET studies. J Nucl Med, 1992, 33: 613–620
Chen B C Germano G, Huang S C, et al. A new noninvasive quantification of renal blood flow with N-13 ammonia, dynamic positron emission tomography, and a two-compartment model. J Am Soc Nephrol, 1992, 3: 1295–1306
Chen K W Bandy D, Reiman E, et al. Noninvasive quantification of the cerebral metabolic rate for glucose using positron emission tomography, 18F-fluoro-2-deoxyglucose, the Patlak method, and an image-derived input function. J Cereb Blood Flow Metab, 1998, 18: 716–723
Parker B, Feng D. Graph-based Mumford-Shah segmentation of dynamic PET with application to input function estimation. IEEE Trans Nucl Sci, 2005, 52: 79–89
Zanotti-Fregonara P, Fadaili E M Maroy R, et al. Comparison of eight methods for the estimation of the image-derived input function in dynamic [18F]-FDG PET human brain studies. J Cereb Blood Flow Metab, 2009, 29: 1825–1835
Feng D, Huang S C Wang X. Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography. Int J Biomed Comput, 1993, 32: 95–110
Phillips R L Chen C Y Wong D F, et al. An improved method to calculate cerebral metabolic rates of glucose using PET. J Nucl Med, 1995, 36: 1668–1679
Takikawa S, Dhawan V, Spetsieris P, et al. Noninvasive quantitative fluorodeoxyglucose PET studies with an estimated input function derived from a population-based arterial blood curve. Radiology, 1993, 188: 131–136
Sundaram S K Freedman N M T Carrasquillo J A, et al. Simplified kinetic analysis of tumor 18F-FDG uptake: A dynamic approach. J Nucl Med, 2004, 45: 1328–1333
Huang S C. Anatomy of SUV. Nucl Med Biol, 2000, 27: 643–646
Patlak C S Blasberg R, Fenstermacher J D. Graphical evaluation of blood to brain transfer constants from multiple-time uptake data. J Cereb Blood Flow Metab, 1983, 3: 1–7
Patlak C S Blasberg R G. Graphical evaluation of blood to brain transfer constants from multiple-time uptake data: Generalizations. J Cereb Blood Flow Metab, 1985, 5: 584–590
Freedman N M T Sundaram S K Kurdziel K, et al. Comparison of SUV and Patlak slope for monitoring of cancer therapy using serial PET scans. Eur J Nucl Med, 2003, 30: 46–53
Visser E P Philippens M E P Kienhorst L, et al. Comparison of tumor volumes derived from glucose metabolic rate maps and SUV maps in dynamic 18F-FDG PET. J Nucl Med, 2008, 49: 892–898
Keyes J W J. SUV: Standard uptake or silly useless value? J Nucl Med, 1995, 36: 1836–1839
Wu Y G. Noninvasive quantification of local cerebral metabolic rate of glucose for clinical application using positron emission tomography and 18F-fluoro-2-deoxy-D-glucose. J Cereb Blood Flow Metab, 2008, 28: 242–250
Lowe V J Kemp B J Jack C R, et al. Comparison of 18F-FDG and PiB PET in cognitive impairment. J Nucl Med, 2009, 50: 878–886
Wang G J Volkow N D Wolf A P, et al. Intersubject variability of brain glucose metabolic measurements in young normal males. J Nucl Med, 1994, 35: 1457–1466
Yakushev I, Landvogt C, Buchholz H G, et al. Choice of reference area in studies of Alzheimer’s disease using positron emission tomography with fluorodeoxyglucose-F18. Psychiatry Res Neuroimaging, 2008, 164: 143–153
Chen K W, Langbaum J, Fleisher A, et al. Twelvemonth metabolic declines in probable Alzheimer’s disease and amnestic mild cognitive impairment assessed using an empirically pre-defined statistical region-of-interest: Findings from the Alzheimer’s disease neuroimaging initiative. NeuroImage, 2010, 51: 654–664
Sokoloff L, Reivich M, Kennedy C, et al. The C-14-deoxyglucose method for the measurement of local cerebral glucose utilization: Theory, procedure, and normal values in the conscious and anesthetized albino rat. J Neurochem, 1977, 28: 897–916
Chen K W Huang S C Yu D C. The effects of measurement errors in the plasma radioactivity curve on parameter estimation in positron emission tomography. Phys Med Biol, 1991, 36: 1183–1200
Feng D, Wong K P Wu C M, et al. A technique for extracting physiological parameters and the required input function simultaneously from PET image measurements: Theory and simulation study. IEEE Trans Inform Technol Biomed, 1997, 1: 243–254
Hasselbalch S G Madsen P L Knudsen G M, et al. Calculation of the FDG lumped constant by simultaneous measurements of global glucose and FDG metabolism in humans. J Cereb Blood Flow Metab, 1998, 8: 154–160
Reivich M, Alavi A, Wolf A, et al. Glucose metabolic rate kinetic model parameter determination in humans: The lumped constants and rate constants for F-18-fluorodeoxyglucose and C-11-deoxyglucose. J Cereb Blood Flow Metab, 1985, 5: 179–192
Huang X R Zhou Y, Bao S L, et al. Clustering based linear least square fitting method for generation of parametric images in dynamic FDG PET studies. Int J Biomed Imaging, 2007, Article ID 65641, doi:10.1155/2007/65641
Wong K P Feng D G Meikle S R. Segmentation of dynamic PET images using cluster analysis. IEEE Trans Nucl Sci, 2002, 49: 200–207
Zhou Y, Huang S C Bergsneider M, et al. Improved parametric image generation using spatial-temporal analysis of dynamic PET studies. NeuroImage, 2002, 15: 697–707
Minoshima S, Frey K A Foster N L, et al. Preserved pontine glucose metabolism in Alzheimer disease: A reference region for functional brain image (PET) analysis. J Comput Assist Tomogr, 1995, 19: 541–547
Kiebel S, Homes A. The General Linear Model. In: Frackowiak R, Friston K, Frith C, et al., eds. Human Brain Function. 2nd ed. San Diego, CA: Elsevier, 2004. 15–16
Author information
Authors and Affiliations
Corresponding authors
Additional information
This article is published with open access at Springerlink.com
Rights and permissions
This article is published under an open access license. Please check the 'Copyright Information' section either on this page or in the PDF for details of this license and what re-use is permitted. If your intended use exceeds what is permitted by the license or if you are unable to locate the licence and re-use information, please contact the Rights and Permissions team.
About this article
Cite this article
Wu, Y., Zhou, Y., Bao, S. et al. Using the rPatlak plot and dynamic FDG-PET to generate parametric images of relative local cerebral metabolic rate of glucose. Chin. Sci. Bull. 57, 3811–3818 (2012). https://doi.org/10.1007/s11434-012-5401-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11434-012-5401-y