Abstract
The n-γ discrimination performance of two experimental arrangements based on the rise-time method and the zero-crossing method was compared for a 50.8 mm-diametered and 50.8 mm-high BC501A liquid scintillator coupled to a 50.8 mm-diametered 9807B photomultiplier in this work. The low energy limitation of the detected neutron with different detector high voltages and the figure of merit of the n-γ discrimination in four neutron energy regions (1–2 MeV, 0.75–1 MeV, 0.5–0.75 MeV and below 0.5 MeV) were studied by using the Am-Be neutron source. Under a time statistical model of the photoelectron emission process in scintillation counters, the intrinsic capability of the n-γ discrimination performance under the optimal condition was evaluated. The experimental results of the zero-crossing method demonstrate a better n-γ. discrimination performance than those of the rise-time method, which is consistent with the calculated results.
Similar content being viewed by others
References
Wong C, Anderson J D, Brown P, et al. Livermore pulsed sphere program: Program summary through July 1972. UCRL-51144, Rev. I
Oyama Y, Maekawa H. Spectral measurement of angular neutron flux on the restricted surface of slab assembles by the Time-of-Flight method. Nucl Instrm Method A, 1986, 245: 173–181
Tomoo N, Kazusuke S. Integral experiments for fusion reactors. Nuclear Data for Science and Technology, 1988 MITO: 171–178
Ichihara C, Kimura I, Yamamoto J, et al. Measurement and analysis of leakage neutron spectrum from a spherical pile of silicon with incident 14 MeV neutrons. J Nucl Sci Technol, 2007, 44(1): 29–35
Moszyński M, Costa G J, Guillaume G, et al. Study of n-γ discrimination with NE213 and BC501A liquid scintillators of different size. Nucl Instrm Method A, 1994, 350: 226–234
Naqvi A, Nagadi M M, Rehman K, et al. Performance comparison of NE213 detectors for their application in moisture measurement. Appl Radiat Isot, 2000, 53: 745–754
Wolski D, Moszyński M, Ludziejewski T, et al. Comparison of n-γ discrimination by zero-crossing and digital charge comparison methods. Nucl Instrm Method A, 1995, 360: 584–592
Post R E, Schiff L I. Statistical limitations on the resolving time of a scintillation counter. Phys Rev, 1950, 80: 1113–1120
Kuchnir F T, Lynch F J. Time dependence of scintillations and the effect on pulse-shape discrimination. IEEE Trans Nucl Sci, 1968, NS-15(9): 107–113
Frank J, Lynch. Basic limitation of scintillation counters in time measurements. IEEE Trans Nucl Sci, 1975, NS-22: 58–64
Gioacchino R. Time statistics of the photoelectron emission process in scintillation counters. Nucl Instrm Method A, 1993, 335: 121–128
Gioacchino R. An analytical approach to the evaluation of the pulse shape discrimination properties of scintillators. Nucl Instrm Method A, 1995, 354: 389–399
Cao Z, Miller L F. Evaluation of pulse shape discrimination performance of scintillation materials and PSD methods by using statistical models. Nucl Instrm Method A, 1998, 416: 32–44
Klein H. Neutron spectrometry in mixed fields: NE213/BC501A liquid scintillation spectrometers. Radiat Prot Dosim, 2003, 107: 95–109
9807B data sheet. http://www.saetong.com/products/ETL/forms/pdf/9807B.pdf
Model 552 Pulse-Shape Analyzer and Timing Single-Channel Analyzer Operating and Service Manual. ORTEC@ Part No.733460, 2002
Klein H, Neumann S. Neutron and photon spectrometry with liquid scintillation detectors in mixed fields. Nucl Instrm Method A, 2002, 476: 132–142
Knoll G F. Radiation Detection and Measurements. New York: John Wiley & Sons Press, 1976
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Yan, J., Liu, R., Li, C. et al. A comparison of n-γ discrimination by the rise-time and zero-crossing methods. Sci. China Phys. Mech. Astron. 53, 1453–1459 (2010). https://doi.org/10.1007/s11433-010-4036-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11433-010-4036-8