Abstract
The wind pressure measurement, especially on curved surfaces is imperative in revealing flow characteristics. The flexible sensor with high linear sensitivity over large pressure range is still a significant challenge, especially for commutatively positive and negative pressure measurement. Here, we propose a conformable, range-programmable capacitive sensor that can extremely extend the measuring range but with high linear sensitivity. The key point is to precisely control the reference pressure of the flexible capacitive sensor array through microchannel network. The proposed sensor with reference pressure 0 kPa keeps stable at a highly-linear sensitivity of 0.28 kPa−1 in an initial measurement regime from 0 to 3 kPa, beyond which the linearity changes significantly. Via the tunable reference pressure, the linear ranges can be customized arbitrarily according to different flight conditions and measured positions, but without any deterioration of sensitivity. The theoretical model is built for the flexible capacitive sensor with tunable reference pressure, agreeing well with the experimental and finite element method results. Additionally, the bending effect is discovered when the flexible sensor is conformed on curved surfaces. This surface-mounted sensor skin is tested on a plate and is integrated with acquisition circuits on a standard airfoil NACA0012 in a wind tunnel and compares with the standard destructive method of pressure taps. It shows great potential applications in measuring wind pressure on curved surfaces, such as for “Fly-by-Feel” of unmanned aerial vehicles and wind tunnel test.
Similar content being viewed by others
References
Kopsaftopoulos F, Nardari R, Li Y H, et al. A stochastic global identification framework for aerospace structures operating under varying flight states. Mech Syst Signal Proc, 2018, 98: 425–447
Yin F, Ye D, Zhu C, et al. Stretchable, highly durable ternary nanocomposite strain sensor for structural health monitoring of flexible aircraft. Sensors, 2017, 17: 2677
Downey A, Laflamme S, Ubertini F. Experimental wind tunnel study of a smart sensing skin for condition evaluation of a wind turbine blade. Smart Mater Struct, 2017, 26: 125005
Qiu L, Yuan S. On development of a multi-channel PZT array scanning system and its evaluating application on UAV wing box. Sens Actuat A-Phys, 2009, 151: 220–230
Nakakita K, Takama Y, Imagawa K, et al. Unsteady PSP measurement of transonic unsteady flow field around a rocket fairing model. In: 28th AIAA Aerodynamic Measurement Technology, Ground Testing, and Flight Testing Conference 2012. New Orleans, 2012. 2758
Ragni D, van Oudheusden B W, Scarano F. Non-intrusive aerodynamic loads analysis of an aircraft propeller blade. Exp Fluids, 2011, 51: 361–371
An L, Lu T, Xu J, et al. Soft sensor for measuring wind pressure. Int J Mech Sci, 2018, 141: 386–392
Kuester M S, Borgoltz A, Devenport W J. Pressure tap effects on the lift measurement of an airfoil section. In: 32nd AIAA Aerodynamic Measurement Technology and Ground Testing Conference. Washington DC, 2016. 3654
Gregory J W, Sakaue H, Liu T, et al. Fast pressure-sensitive paint for flow and acoustic diagnostics. Ann Rev Fluid Mech, 2014, 46: 303–330
Shi R, Lou Z, Chen S, et al. Flexible and transparent capacitive pressure sensor with patterned microstructured composite rubber dielectric for wearable touch keyboard application. Sci China Mater, 2018, 61: 1587–1595
Kim S Y, Park S, Park H W, et al. Highly sensitive and multimodal all-carbon skin sensors capable of simultaneously detecting tactile and biological stimuli. Adv Mater, 2015, 27: 4178–4185
Kim H, Kim G, Kim T, et al. Transparent, flexible, conformal capacitive pressure sensors with nanoparticles. Small, 2018, 14: 1703432
Hu J Q, Li R, Liu Y, et al. An overview of healthcare monitoring by flexible electronics. Sci China-Phys Mech Astron, 2018, 61: 094601
Zhao X, Hua Q, Yu R, et al. Flexible, stretchable and wearable multifunctional sensor array as artificial electronic skin for static and dynamic strain mapping. Adv Electron Mater, 2015, 1: 1500142
Han L B, Ding J N, Wang S, et al. Multi-functional stretchable and flexible sensor array to determine the location, shape, and pressure: Application in a smart robot. Sci China Tech Sci, 2018, 61: 1137–1143
Lee H K, Chung J, Chang S I, et al. Normal and shear force measurement using a flexible polymer tactile sensor with embedded multiple capacitors. J Microelectromech Syst, 2008, 17: 934–942
Huang Y A, Wu H, Xiao L, et al. Assembly and applications of 3D conformal electronics on curvilinear surfaces. Mater Horiz, 2019, 6: 642–683
Lu N, Kim D H. Flexible and stretchable electronics paving the way for soft robotics. Soft Robot, 2014, 1: 53–62
Mannsfeld S C B, Tee B C K, Stoltenberg R M, et al. Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers. Nat Mater, 2010, 9: 859–864
He Z, Chen W, Liang B, et al. Capacitive pressure sensor with high sensitivity and fast response to dynamic interaction based on graphene and porous nylon networks. ACS Appl Mater Interfaces, 2018, 10: 12816–12823
Zang Y, Zhang F, Huang D, et al. Flexible suspended gate organic thin-film transistors for ultra-sensitive pressure detection. Nat Commun, 2015, 6: 6269
Zang Y, Zhang F, Di C, et al. Advances of flexible pressure sensors toward artificial intelligence and health care applications. Mater Horiz, 2015, 2: 140–156
Lee S, Kim J, Yun I, et al. An ultrathin conformable vibration-responsive electronic skin for quantitative vocal recognition. Nat Commun, 2019, 10: 2468
Lee Y, Park J, Cho S, et al. Flexible ferroelectric sensors with ultrahigh pressure sensitivity and linear response over exceptionally broad pressure range. ACS Nano, 2018, 12: 4045–4054
Chen Y, Yu M, Bruck H A, et al. Characterization of a compliant multi-layer system for tactile sensing with enhanced sensitivity and range. Smart Mater Struct, 2018, 27: 065005
Liao K W, Hou M T, Fujita H, et al. Liquid-based tactile sensing array with adjustable sensing range and sensitivity by using dielectric liquid. Sens Actuat A-Phys, 2015, 231: 15–20
Lai Y T, Chen Y M, Liu T, et al. A tactile sensing array with tunable sensing ranges using liquid crystal and carbon nanotubes composites. Sens Actuat A-Phys, 2012, 177: 48–53
Francioso L, De Pascali C, Siciliano P, et al. Aircraft distributed flow turbulence sensor network with embedded flow control actuators. In: 2014 12th IEEE International Conference on Embedded and Ubiquitous Computing. Milano, 2014. 185–192
Jenett B, Calisch S, Cellucci D, et al. Digital morphing wing: Active wing shaping concept using composite lattice-based cellular structures. Soft Robot, 2017, 4: 33–48
Guo Z, Kim K, Salowitz N, et al. Functionalization of stretchable networks with sensors and switches for composite materials. Struct Health Monitoring, 2018, 17: 598–623
Elgamel H E A. A simple and efficient technique for the simulation of capacitive pressure transducers. Sens Actuat A-Phys, 1999, 77: 183–186
Wygant I O, Kupnik M, Khuri-Yakub B T. Analytically calculating membrane displacement and the equivalent circuit model of a circular CMUT cell. In: 2008 IEEE Ultrasonics Symposium. Beijing, 2008. 2111–2114
Timoshenko S P, Woinowsky-Krieger S. Theory of Plates and Shells. Columbus: McGraw-Hill Publishing, 1959. 396–425
Rahman M M, Chowdhury S. Square diaphragm CMUT capacitance calculation using a new deflection shape function. J Sens, 2011, 2011: 581910
Maier-Schneider D, Maibach J, Obermeier E. A new analytical solution for the load-deflection of square membranes. J Microelectromech Syst, 1995, 4: 238–241
Niklaus F, Stemme G, Lu J Q, et al. Adhesive wafer bonding. J Appl Phys, 2006, 99: 2
Metz S, Holzer R, Renaud P. Polyimide-based microfluidic devices. Lab Chip, 2001, 1: 29–34
Chien W Z. Asymptotic behavior of a thin clamped circular plate under uniform normal pressure at very large deflection. Sci Rep Nat Tsinghua Univ, 1948, 5: 71–94
Noda K, Matsumoto K, Shimoyama I. Stretchable tri-axis force sensor using conductive liquid. Sens Actuat A-Phys, 2014, 215: 123–129
Wang S, Xiao J, Song J, et al. Mechanics of curvilinear electronics. Soft Matter, 2010, 6: 5757–5763
Kim D H, Chang J W. Low-Reynolds-number effect on the aerodynamic characteristics of a pitching NACA0012 airfoil. Aerosp Sci Tech, 2014, 32: 162–168
Author information
Authors and Affiliations
Corresponding author
Additional information
The general characterization facilities were provided by the Flexible Electronics Manufacturing Laboratory in Comprehensive Experiment Center for Advanced Manufacturing Equipment and Technology at Huazhong University of Science and Technology. This work was supported by the National Natural Science Foundation of China (Grant Nos. 51635007 and 51925503) and the Fundamental Research Funds for the Central Universities (Grant No. 2016YXZD068).
Rights and permissions
About this article
Cite this article
Xiong, W., Guo, D., Yang, Z. et al. Conformable, programmable and step-linear sensor array for large-range wind pressure measurement on curved surface. Sci. China Technol. Sci. 63, 2073–2081 (2020). https://doi.org/10.1007/s11431-020-1642-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11431-020-1642-4