Abstract
In order to assess indoor air quality (IAQ), two 1-week monitoring campaigns of volatile organic compounds (VOC) were performed in different areas of a multistorey shopping mall. High-spatial-resolution monitoring was conducted at 32 indoor sites located in two storehouses and in different departments of a supermarket. At the same time, VOC concentrations were monitored in the mall and parking lot area as well as outdoors. VOC were sampled at 48-h periods using diffusive samplers suitable for thermal desorption. The samples were then analyzed with gas chromatography–mass spectrometry (GC–MS). The data analysis and chromatic maps indicated that the two storehouses had the highest VOC concentrations consisting principally of terpenes. These higher TVOC concentrations could be a result of the low efficiency of the air exchange and intake systems, as well as the large quantity of articles stored in these small spaces. Instead, inside the supermarket, the food department was the most critical area for VOC concentrations. To identify potential emission sources in this department, a continuous VOC analyzer was used. The findings indicated that the highest total VOC concentrations were present during cleaning activities and that these activities were carried out frequently in the food department. The study highlights the importance of conducting both high-spatial-resolution monitoring and high-temporal-resolution monitoring. The former was able to identify critical issues in environments with a complex emission scenario while the latter was useful in interpreting the dynamics of each emission source.
Similar content being viewed by others
References
Baek SK, Kim YS, Perry R (1997) Indoor air quality in homes, offices and restaurants in Korean urban areas—indoor/outdoor relationships. Atmos Environ 31:529–544
Batterman S, Ji C, Hatzivasilis G (2007) Migration of volatile organic compounds from attached garages to residences: a major exposure source. Environ Res 104(2):224–240
Biasi E (2012) Rapporto 2012 sui Centri Commerciali in Italia. MARK UP and Sincron Inova
Brinke JT, Selvin S, Hodgson AT (1998) Development of new volatile organic compound (VOC) exposure metrics and their relationship to “sick building syndrome” symptoms. Indoor Air 8:140–152
Bruno P, Caputi M, Caselli M, de Gennaro G, de Rienzo M (2005) Reliability of a BTEX radial diffusive sampler for thermal desorption: field measurements. Atmos Environ 39:1347–1355
Bruno P, Caselli M, de Gennaro G, Iacobellis S, Tutino M (2008) Monitoring of volatile organic compounds in non-residential indoor environments. Indoor Air 18:250–256
Bruno P, Caselli M, de Gennaro SM, Tutino M (2009) Indoor contaminants from newspapers: VOC emission in newspaper stands. Environ Res 109:149–157
Carslaw N (2013) A mechanistic study of limonene oxidation products and pathways following cleaning activities. Atmos Environ 80:507–513
Chang CJ, Yang HH, Chang CA, Tsai HY (2013) Volatile organic compounds and nonspecific conjunctivitis: a population-based study. Aerosol Air Qual Res 13:237–242
Chao CY, Chan GY (2001) Quantification of indoor VOCs in twenty mechanically ventilated buildings in Hong Kong. Atmos Environ 35(34):5895–5913
Eklund BM, Burkes S, Morris P, Mosconi L (2008) Spatial and temporal variability in VOC levels within a commercial retail building. Indoor Air 18(5):365–374
Iregren A (2000) Effect on human body from acute and chronic exposure to organic solvent: a short review. Toxicology 49:349–358
ISO 16000-6 (2011) Indoor air -part 6: determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID
Jones AP (1999) Indoor air quality and health. Atmos Environ 33:4535–4564
Kampa M, Castanas E (2008) Human health effects of air pollution. Environ Pollut 151:362–367
Kim YM, Harrad S, Harrison RM (2001) Concentrations and sources of VOCs in urban domestic and public microenvironments. Environ Sci Technol 35:997–1004
Kostiainen R (1995) Volatile organic compounds in the indoor air of normal and sick houses. Atmos Environ 29(6):693–702
Kotzias D (2005) Indoor air and human exposure assessment—needs and approaches. Exp Toxicol Pathol 57:5–7
Lee SC, Guo H, Li WM, Chan LY (2002) Inter-comparison of air pollutant concentrations in different indoor environments in Hong Kong. Atmos Environ 36:1929–1940
Loh MM, Houseman EA, Gray GM, Levy JI, Spengler JD, Bennet DH (2006) Measured concentrations of VOCs in several non-residential microenvironments in the United States. Environ Sci Technol 40:6903–6911
Nazaroff WW, Weschler CJ (2004) Cleaning products and air fresheners: exposure to primary and secondary air pollutants. Atmos Environ 38:2841–2865
Pegas PN, Alves CA, Evtyugina MG, Nunes T, Cerqueira M, Franchi M, Pio CA, Almeida SM, Freitas MC (2011) Indoor air quality in elementary schools of Lisbon in spring. Environ Geochem Health 33(5):455–468
Radiello (2013) http://www.radiello.com/english/index_en.htmlS>. Accessed June 2013
Ramírez N, Cuadras A, Rovira E, Borrull F, Marcé RM (2012) Chronic risk assessment of exposure to volatile organic compounds in the atmosphere near the largest Mediterranean industrial site. Environ Int 39:200–209
Rumchev K, Brown H, Spickett J (2007) Volatile organic compounds: do they present a risk to our health? Rev Environ Health 22:39–55
Tang J, Chan CY, Wang X, Chan LY, Sheng G, Fu J (2005) Volatile organic compounds in a multi-storey shopping mall in Guangzhou, South China. Atmos Environ 39:7374–7383
UNI EN 14412 (2005) Indoor air quality—diffusive samplers for the determination of concentrations of gases and vapours—guide for selection, use and maintenance
UNI EN ISO 16000-1 (2006) Indoor air—part 1: general aspects of sampling strategy
UNI EN ISO 16000-5 (2007) Indoor air—part 5: sampling strategy for volatile organic compounds (VOCs)
UNI EN ISO 16017-2 (2007) Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography. Part 2: diffusive sampling
Vu TP, Lee SB, Bae GN (2013) Effect of temperature on aerosol formation potential for a terpene-rich air freshener in the presence of ozone. Indoor Built Environ 22(5):808–821
Wolkoff P (2013) Indoor air pollutants in office environments: assessment of comfort, health, and performance. Int J Hyg Environ Health 216:371–394
Zhou J, You Y, Bai Z, Hu Y, Zhang J, Zhang N (2011) Health risk assessment of personal inhalation exposure to volatile organic compounds in Tianjin, China. Sci Total Environ 409:452–459
Author information
Authors and Affiliations
Corresponding author
Additional information
Responsible editor: Constantini Samara
Rights and permissions
About this article
Cite this article
Amodio, M., Dambruoso, P.R., de Gennaro, G. et al. Indoor air quality (IAQ) assessment in a multistorey shopping mall by high-spatial-resolution monitoring of volatile organic compounds (VOC). Environ Sci Pollut Res 21, 13186–13195 (2014). https://doi.org/10.1007/s11356-014-2544-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11356-014-2544-1