Skip to main content

Advertisement

Log in

Systematic assessment of the impact of oral appliance therapy on the temporomandibular joint during treatment of obstructive sleep apnea: long-term evaluation

  • Original Article
  • Published:
Sleep and Breathing Aims and scope Submit manuscript

Abstract

Objective

The aim of the present study was to evaluate the symptoms of temporomandibular dysfunction (TMD) in patients with obstructive sleep apnea treated with long-term use of an oral appliance (OA) using a questionnaire based on the Helkimo Anamnestic Dysfunction Index. A further aim of the study was to evaluate the presence of daytime sleepiness using the Epworth Sleep Scale (ESS) and otologic symptoms.

Materials and methods

Polysomnograms of 34 patients were performed at baseline and after 6 months of OA use. As follow-up, the patients were contacted by telephone interview to answer the same questionnaires after 36.0 ± 17.0 months.

Results and discussion

The intensity of TMD symptoms decreased significantly throughout treatment (p < 0.01). ESS values improved from 12.2 ± 5.0 to 6.9 ± 2.6 (p ≤ 0.05). Tinnitus was present in nine patients at baseline and decreased in intensity in seven patients by the final assessment while remaining at the same level in two patients.

Conclusions

We conclude that long-term usage of an OA does not cause impairment to the temporomandibular joint. The Helkimo and otologic indexes are simple and useful in long-term patient follow-up. There was a long-term improvement in the ESS values over the years analyzed. A follow-up program could increase compliance by motivating patients to use the device regularly.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Kushida CA, Morgenthaler TI, Littner MR, Alessi CA, Bailey D, Coleman J, Friedman L, Hirshkowitz M, Kapen S, Kramer M, Lee-Chiong T, Owens J, Pancer JP, American Academy of Sleep Medicine (2006) Practice parameters for the treatment of snoring and obstructive sleep apnea with oral appliances: an update for 2005. Sleep 29(2):240–243

    PubMed  Google Scholar 

  2. Giannasi LC, Mattos LC, Magini M, Costa MS, Oliveira CS, Oliveira LVF (2008) The impact of the PMPositioner appliance in the treatment of obstructive sleep apnoea. Arch Med Sci 4(3):336–341

    Google Scholar 

  3. Coruzzi P, Gualerzi M, Bernkopf E, Brambilla L, Brambilla V, Broia V, Lombardi C, Parati G (2006) Autonomic cardiac modulation in obstructive sleep apnea: effect of an oral jaw-positioning appliance. Chest 13:1362–1368. doi:10.1378/chest.130.5.1362

    Article  Google Scholar 

  4. Otsuka R, Ribeiro de Almeida F, Lowe AA, Linden W, Ryan F (2006) The effect of oral appliance therapy on blood pressure in patients with obstructive sleep apnea. Sleep Breath 10:29–36. doi:10.1007/s11325-005-0038-6

    Article  PubMed  Google Scholar 

  5. Schuwarting S, Huebers U, Heise M, Schlieper J, Hauschild A (2007) Position paper on the use of mandibular advancement devices in adults with sleep-related breathing disorders: a position paper of the German Society of Dental Sleep Medicine (Deutsche Gesellschaft Zahnaerztliche Schlafmedizin, DGZS). Sleep Breath 11:125–126. doi:10.1007/s11325-007-0116-z

    Article  Google Scholar 

  6. Hoffstein V (2007) Review of oral appliances for treatment of sleep-disordered breathing. Sleep Breath 11:1–22. doi:10.1007/s11325-006-0084-8

    Article  PubMed  Google Scholar 

  7. Pancer J, Al-Faifi S, Al-Faifi M, Hoffstein V (1999) Evaluation of variable mandibular advancement appliance for treatment of snoring and sleep apnea. Chest 116:1511–1518. doi:10.1378/chest.116.6.1511

    Article  CAS  PubMed  Google Scholar 

  8. Pantin CC, Hillman DR, Tennant M (1999) Dental side effects of an oral device to treat snoring and obstructive sleep apnea. Sleep 9(22):237–240

    Google Scholar 

  9. Bondemark L (1999) Does 2-years’ nocturnal treatment with a mandibular advancement splint in adult patients with snoring and OSAS cause a change in the posture of the mandible? Am J Orthod Dentofacial Orthop 116:621–628. doi:10.1016/S0889-5406(99)70196-4

    Article  CAS  PubMed  Google Scholar 

  10. Fritsch KM, Iseli A, Russi EW, Bloch KE (2001) Side effects of mandibular advancement devices for sleep apnea treatment. Am J Respir Crit Care Med 164:813–818

    CAS  PubMed  Google Scholar 

  11. Marklund M, Sahlin C, Stenlund S, Persson M, Franklin KA (2001) Mandibular adavancement device in patients with obstructive sleep apnea: long-term effects on apnea and sleep. Chest 120:162–169. doi:10.1378/chest.120.1.162

    Article  CAS  PubMed  Google Scholar 

  12. Marklund M, Franklin KA, Persson M (2001) Orthodontics side-effects of mandibular advancement devices during treatment of snoring and sleep apnea. Eur J Orthod 23:135–144. doi:10.1093/ejo/23.2.135

    Article  CAS  PubMed  Google Scholar 

  13. Walker-Engström ML, Tegelberg A, Wilhelmsson B, Ringqvist I (2002) 4-year follow-up of treatment with dental appliance or uvopalatopharyngoplasty in patients with obstructive sleep apnea: a randomized study. Chest 121:734–746. doi:10.1378/chest.121.3.739

    Article  Google Scholar 

  14. Rose EC, Staats R, Virchow C Jr, Jonas IE (2002) Occlusal and skeletal effects of an oral appliance in the treatment of sleep apnea. Chest 122:871–877. doi:10.1378/chest.122.3.871

    Article  PubMed  Google Scholar 

  15. de Almeida FR, Bittencourt LR, de Almeida CI, Tsuiki S, Lowe AA, Tufik S (2002) Effects of mandibular posture on apnea severity and the temporomandibular joint in patients fitted obstructive sleep with an oral appliance. Sleep 25:507–513

    PubMed  Google Scholar 

  16. Jonhston CD, Gleadhill IC, Cinnamond MJ, Gabbey J, Burden DJ (2002) Mandibular advancement appliances and obstructive sleep apnoea: a randomized clinic trial. Eur J Orthod 24:251–262. doi:10.1093/ejo/24.3.251

    Article  Google Scholar 

  17. Marklund M (2004) Mandibular advancement devicecs in 630 men and women with obstructive sleep apnea and snoring: tolerability predictors treat success. Chest 125:1270–1278

    Article  PubMed  Google Scholar 

  18. Almeida FR, Lowe AA, Sung JO, Tsuiki S, Otsuka R (2006) Long-term sequellae of oral appliance therapy in obstructive sleep apnea patients: part 1. Cephalometric analysis. Am J Orthod Dentofacial Orthop 129:195–204. doi:10.1016/j.ajodo.2005.10.001

    Article  PubMed  Google Scholar 

  19. Walker-Engström ML, Ringqvist I, Vestling O, Wilhelmsson B, Tegelberg AA (2003) Prospective randomized study comparing two different degrees of mandibular advancement with a dental appliance in treatment of severe obstructive sleep apnea. Sleep Breath 10:119–130. doi:10.1007/s11325-003-0119-3

    Article  Google Scholar 

  20. Helkimo M (1974) Studies on function and dysfunction of the masticatory system. II. Index for anamnestic and clinical dysfunction and occlusal state. Sven Tandlak Tidskr 67(2):101–121

    CAS  PubMed  Google Scholar 

  21. Dimitroulis G (1998) Temporomandibular disorders: a clinical update. BMJ 18;317(7152):190–194

    Google Scholar 

  22. Ramirez LM, Ballesteros LE, Sandoval GP (2007) Tensor tympani muscle: strange chewing muscle. Med Oral Patol Oral Cir Bucal 12(2):E96–E100

    PubMed  Google Scholar 

  23. Costen JB (1997) A syndrome of ear and sinus symptoms dependent upon disturbed function of the temporomandibular joint.1934. Ann Otol Rhinol Laryngol 106(10 Pt 1):805–819

    CAS  PubMed  Google Scholar 

  24. Salvetti G, Manfredini D, Barsotti S, Bosco M (2006) Otologic symptoms in temporomandibular disorders patients: is there evidence of an association-relationship? Minerva Stomatol 55(11–12):627–637

    CAS  PubMed  Google Scholar 

  25. McGown AD, Makker HK, Battagel JM, L’Estrange PR, Grant HR, Spiro SG (2001) Long-term use of mandibular advancement splints for snoring and obstructive sleep apnoea: a questionnaire survey. Eur Respir J 17:462–466. doi:10.1183/09031936.01.17304620

    Article  CAS  PubMed  Google Scholar 

  26. Petit F-X, Pépin JL, Bettega G, Sadek H, Raphäel B, Lévy P (2002) Mandibular advancement devices rate of contraindications in 100 consecutive obstructive sleep apnea pacients. Am J Respir Crit Care Med 166:274–278. doi:10.1164/rccm.2008167

    Article  PubMed  Google Scholar 

  27. Almeida FR, Lowe AA, Tsuiki S, Otsuka R, Wong M, Fastlicht S, Ryan F (2005) Long-term compliance and side effects of oral appliances used for the treatment of snoring and obstructive sleep apnea syndrome. J Clin Sleep Med 1(2):143–152

    PubMed  Google Scholar 

  28. Johns MW (1993) Daytime sleepiness, snoring, and obstructive sleep apnea. The Epworth Sleep Scale. Chest 103:30–36. doi:10.1378/chest.103.1.30

    Article  CAS  PubMed  Google Scholar 

  29. Smith BGN, Knight JK (1984) An index for measuring the wear and tear of teeth. Br Dent J 156:435–438. doi:10.1038/sj.bdj.4805394

    Article  CAS  PubMed  Google Scholar 

  30. Nascimento LL, Amorin CF, Giannasi LC, Oliveira CS, Nacif SR, Silva AM, Nascimento DFF, Marchini L, Oliveira LVF (2008) Occlusal splint for sleep bruxism: an electromyographic associated to Helkimo index evaluation. Sleep Breath 12(3):275–280. doi:10.1007/s11325-007-0152-8

    Article  PubMed  Google Scholar 

  31. Clark GT, Blumenfeld I, Yoffe N, Peled E, Lavie P (1996) A crossover study comparing the efficacy of continuous positive airway with anterior mandibular positioning devices on patients with obstructive sleep apnea. Chest 109:1477–1483 excluir

    Article  CAS  PubMed  Google Scholar 

  32. Ferguson KA, Ono T, Lowe AA, Keenan SP, Fleetham JA (1996) A randomized crossover study of an oral appliance vs nasal-continuous positive airway pressure in the treatment of mild–moderate obstructive sleep apnea. Chest 109:1269–1275. doi:10.1378/chest.109.5.1269

    Article  CAS  PubMed  Google Scholar 

  33. Ryan CF, Love L, Peat D, Fleethan J, Lowe AA (1999) Mandibular advancement oral appliance therapy for obstructive sleep apnea: effect on awake caliber of the velopharynx. Thorax 54:972–977

    Article  CAS  PubMed  Google Scholar 

  34. Tsuiki S, Hiyama S, Ono T, Imamura N, Ishiwata Y, Kuroda T (2001) Effects of a titratable oral appliance on supine airway size in awake non-apneic individuals. Sleep 24:554–560

    CAS  PubMed  Google Scholar 

  35. Tsuiki S, Lowe AA, Almeida FR, Fleetham JA (2004) Effects of an anteriorly titrated mandibular position on awake airway and obstructive sleep apnea severity. Am J Orthod Dentofacial Orthop 125:548–555. doi:10.1016/j.ajodo.2003.05.006

    Article  PubMed  Google Scholar 

  36. Engleman HM, Kingshott RN, Wraith PK, Mackay TW (1999) Randomized placebo-controlled crossover trial of continuous positive airway pressure for mild sleep apnea/hypopnea syndrome. Am J Respir Crit Care Med 159:461–467

    CAS  PubMed  Google Scholar 

Download references

Acknowledgment

We thank Fundaçao de Amparo a Pesquisa do Estado de Sao Paulo (local acronym FAPESP) and Conselho Nacional de Pesquisa (local acronym CNPq) for supporting this research.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Lílian C. Giannasi.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Giannasi, L.C., Almeida, F.R., Magini, M. et al. Systematic assessment of the impact of oral appliance therapy on the temporomandibular joint during treatment of obstructive sleep apnea: long-term evaluation. Sleep Breath 13, 375–381 (2009). https://doi.org/10.1007/s11325-009-0257-3

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11325-009-0257-3

Keywords

Navigation