Abstract
For many pumping stations that draw water from sediment-laden rivers, the flow patterns in their intake structure are disordered due to sediment deposition, which seriously threatens the safe operation of projects. In order to accurately construct the complex and refined three-dimensional (3D) geometric model of the intake structure, and further explore the hydraulic characteristics of the water–sediment two-phase flow inside, this paper proposes a reverse modeling method and carries out numerical simulation. A typical forward intake structure in the arid region of Northwest China is selected as the research object. According to the point cloud data of the intake structure obtained by the 3D laser scanner, the curved surface models are rebuilt and imported into ICEM-CFD for improvement, thereby obtaining the 3D computational domain model of the actual intake structure; after lossless docking with FLUENT, the hydraulic characteristics are analyzed by applying the Realizable k-ε turbulence model coupled with the Mixture multiphase flow model considering interphase slip; finally, the reliability of the simulation is verified by in-situ flow measurements. Results demonstrate that the method can precisely reflect the actual geometric boundary and siltation of intake structure, and the numerical model can accurately identify the two-phase flow; the siltation improves the local flow field structure of the forebay to some extent, but cause the loss of the overall hydraulic performance of the intake structure. This study can provide a scientific reference for the geometric model construction and hydraulic analysis of intake structures with complex boundary and sediment deposition.
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs11269-022-03385-w/MediaObjects/11269_2022_3385_Fig1_HTML.png)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs11269-022-03385-w/MediaObjects/11269_2022_3385_Fig2_HTML.png)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs11269-022-03385-w/MediaObjects/11269_2022_3385_Fig3_HTML.png)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs11269-022-03385-w/MediaObjects/11269_2022_3385_Fig4_HTML.png)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs11269-022-03385-w/MediaObjects/11269_2022_3385_Fig5_HTML.jpg)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs11269-022-03385-w/MediaObjects/11269_2022_3385_Fig6_HTML.jpg)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs11269-022-03385-w/MediaObjects/11269_2022_3385_Fig7_HTML.jpg)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs11269-022-03385-w/MediaObjects/11269_2022_3385_Fig8_HTML.png)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs11269-022-03385-w/MediaObjects/11269_2022_3385_Fig9_HTML.png)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs11269-022-03385-w/MediaObjects/11269_2022_3385_Fig10_HTML.png)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs11269-022-03385-w/MediaObjects/11269_2022_3385_Fig11_HTML.png)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs11269-022-03385-w/MediaObjects/11269_2022_3385_Fig12_HTML.png)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs11269-022-03385-w/MediaObjects/11269_2022_3385_Fig13_HTML.png)
Similar content being viewed by others
Availability of Data and Materials
The data generated and/or analyzed during the current study are available from the corresponding author on reasonable request.
References
Afzali S, Rezaei N, Zendehboudi S, Chatzis I (2022) Computational fluid dynamic simulation of multi-phase flow in fractured porous media during water-alternating-gas injection process. J Hydrol. https://doi.org/10.1016/j.jhydrol.2022.127852
Ansar M, Nakato T (2001) Experimental study of 3D pump-intake flows with and without cross Flow. J Hydraul Eng 127(10):825–834
Aryan A, Bosche F, Tang P (2021) Planning for terrestrial laser scanning in construction: A review. Autom Constr. https://doi.org/10.1016/j.autcon.2021.103551
Bermúdez M, Cea L, Puertas J, Conde A, Martín A, Baztán J (2017) Hydraulic model study of the intake-outlet of a pumped-storage hydropower plant. Eng Appl Comput Fluid Mech 11(1):483–495
Cant S (2007) Introduction to computational fluid dynamics. J Fluid Mech 572
Chai T, Draxler RR (2014) Root mean square error (RMSE) or mean absolute error (MAE)? - Arguments against avoiding RMSE in the literature. Geosci Model Dev 7(3):1247–1250
Chang T-J, Wang C-H, Chen AS, Djordjević S (2018) The effect of inclusion of inlets in dual drainage modelling. J Hydrol 559:541–555
Cheng S, Wu W, Yang X, Zhang H, Zhang X (2011) Rapid surfacing reconstruction based on Geomagic Studio software. Mod Manuf Eng, 8–12
Dabous SA, Feroz S (2020) Condition monitoring of bridges with non-contact testing technologies. Autom Construct 116:103224
Du J, Shen Z, Yang H (2018) Effects of different block designs on the performance of inline cross-flow turbines in urban water mains. Appl Energy 228:97–107
Gao X, Li L, Liao X, Wang X, Chen Z (2020) Numerical simulation analysis of stability of unstable rock mass with reverse engineering modeling method. J Eng Geol 28:557–564
Hendi E, Shamseldin AY, Melville BW (2022) The effect of inlet width on the performance of sediment retention ponds in thermally induced flows. J Hydrol. https://doi.org/10.1016/j.jhydrol.2021.127377
Hodson TO (2022) Root-mean-square error (RMSE) or mean absolute error (MAE): when to use them or not. Geosci Model Dev 15:5481–5487
Launder BE, Spalding DB (1972) Lectures in mathematical model of turbulence. Academic Press
Li M, Khan TS, Hajri EA, Ayub ZH (2016) Geometric optimization for thermal–hydraulic performance of dimpled enhanced tubes for single phase flow. Appl Therm Eng 103:639–650
Liu J, Li M, Wu M, Luan X, Wang W, Yu Z (2020) Influences of the south–to-north water diversion project and virtual water flows on regional water resources considering both water quantity and quality. J Clean Prod 244:118920
Liu W, Sun Y (2008) Principle, method and application of reverse engineering. China Machine Press, China
Liu X, Pu X, Luo D, Lu J, Liu Z (2019) Model assessment of nutrient removal via planting Sesuvium portulacastrum in floating beds in eutrophic marine waters: the case of aquaculture areas of Dongshan Bay. Acta Oceanol Sin 38:91–100. https://doi.org/10.1007/s13131-019-1492-5
Lu L-B, Tian Y, Lei X-H, Wang H, Qin T, Zhang Z (2018) Numerical analysis of the hydraulic transient process of the water delivery system of cascade pump stations. Water Sci Technol Water Supply 18:1635–1649
Ma W, Kruth JP (1998) NURBS curve and surface fitting for reverse engineering. Int J Adv Manuf Technol 14:918–927
Manninen M, Taivassalo V, Kallio S (1996) Mixture model for multiphase flow
Nakato T (2000) Pumping station design, 2nd edn. J Hydraul Eng 126(8):632–633
Shih TH, Liou WW, Shabbir A, Yang Z, Jiang Z (1995) A new k-e eddy viscosity model for high Reynolds number turbulent flows. Comput Fluids 24:227–238
Trebuňa P, Mizerák M, Trojan J, Rosocha L (2020) 3D scanning as a modern technology for creating 3D models. Acta Tecnol 6:21–24
Wang F, Tang X, Chen X, Xiao R, Yang W (2018) A review on flow analysis method for pumping stations. Shuili Xuebao/J Hydraul Eng 49, 47–61 and 71
Wang Y, Zhang W, Zhao Y, Peng H, Shi Y (2016) Modelling water quality and quantity with the influence of inter-basin water diversion projects and cascade reservoirs in the Middle-lower Hanjiang River. J Hydrol 541:1348–1362
Yakhot V, Orszag SA (1986) Renormalization group analysis of turbulence. I. Basic theory. J Sci Comput 1(1):3–51
Yan P, Zhang Z, Lei X, Hou Q, Wang H (2022) A multi-objective optimal control model of cascade pumping stations considering both cost and safety. J Clean Prod. https://doi.org/10.1016/j.jclepro.2022.131171
Zeng M, Tao WQ (2003) A comparison study of the convergence characteristics and robustness for four variants of SIMPLE-family at fine grids. Eng Comput 20(3):320–340
Zhang H, Gao X, Sun B, Qin Z, Zhu H (2020) Parameter analysis and performance optimization for the vertical pipe intake-outlet of a pumped hydro energy storage station. Renew Energy 162:1499–1518
Zi D, Wang F, Yao Z, Ye C, Xu J, Li D (2017) Research on optimization method of pump sump parameters based on response surface model. J Hydraul Eng 48(5):594–607
Funding
This work is supported by the National Natural Science Foundation of China (51579102), the Scientific and Technological Innovation Team Support Program for Colleges and Universities in Henan Province (19IRTSTHN030), the Central Plains Science and Technology Innovation Leading Talents Support Program (204200510048), the Key R&D program of Zhejiang Provinc (2021C03019), and the Doctoral Innovation Fund of North China University of Water Resources and Electric Power.
Author information
Authors and Affiliations
Contributions
All authors contributed to the study conception and design. Material preparation, data collection and analysis were performed by Junjiao Tian, Zijin Liu, Rongrong Wang and Guoxia Wang. The first draft of the manuscript was written by Cundong Xu and Junjiao Tian, and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics Approval
All authors kept the “Ethical Responsibilities of Authors”.
Consent to Participate
All authors gave explicit consent to participate in this study.
Consent for Publication
All authors gave explicit consent to publish this manuscript.
Competing Interests
The authors have no relevant financial or non-financial interests to disclose.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Xu, C., Tian, J., Liu, Z. et al. Three-dimensional Reverse Modeling and Hydraulic Analysis of the Intake Structure of Pumping Stations on Sediment-laden Rivers. Water Resour Manage 37, 537–555 (2023). https://doi.org/10.1007/s11269-022-03385-w
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11269-022-03385-w