Skip to main content
Log in

Potentiometric Sensor for Benzylpenicillin Determination

  • STRUCTURE OF CHEMICAL COMPOUNDS, METHODS OF ANALYSIS AND PROCESS CONTROL
  • Published:
Pharmaceutical Chemistry Journal Aims and scope

A potentiometric benzylpenicillin-sensitive sensor with a plasticized polyvinyl-chloride membrane was developed. The sensor contains a benzylpenicillin—rhodamine 6G ion pair. The response is linear for benzylpenicillin concentrations in the range 10–3 – 10–1M with an electrode-function slope characteristic of singly charged anions and a minimum detected concentration of (6.3 – 7.9) × 10–4 M. This sensor could be used to detect and determine benzylpenicillin in pharmaceuticals.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.

Similar content being viewed by others

References

  1. D. D. Tzvetkova, D. P. Obreshkova, and I. P. Pencheva, Slov. Vet. Res., 42(1) / 2, 23 – 29 (2005); https: //www.slovetres.si / index. php/SVR/issue/view/41.

  2. M. Marchetti, I. Schwaiger, and E. Schmid, Fresenius’ J. Anal. Chem., 371(1), 64 – 67 (2001); doi:https://doi.org/10.1007/s002160100858.

    Article  CAS  Google Scholar 

  3. E. G. Kulapina, S. V. Snesarev, N. M. Makarova, et al., J. Anal. Chem., 66(1), 78 – 83 (2011); doi:10.1134 /S1061934811010084.

  4. Z. Kormosh and T. Savchuk, Mater. Sci. Eng. C, 32, 2286 – 2291 (2012); doi:10.1016 / j.msec.2012.06.016.

  5. Zh. Kormosh and T. Savchuk, Pharm. Chem. J., 46(3), 196 – 198 (2012); doi:https://doi.org/10.1007/s11094-016-1489-8.

    Article  CAS  Google Scholar 

  6. Yu. Yu. Lur’e, Handbook of Analytical Chemistry [in Russian], Khimiya, Moscow, 1989.

  7. State Pharmacopoeia of Ukraine, Gos. Predpriyatie Nauchno-Ekspert. Farm. Tsentr, Kharkiv, 2004.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Zh. A. Kormosh.

Additional information

Translated from Khimiko-Farmatsevticheskii Zhurnal, Vol. 53, No. 6, pp. 62 – 64, June, 2019.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kormosh, Z.A., Markovska, N.A. & Kormosh, N.N. Potentiometric Sensor for Benzylpenicillin Determination. Pharm Chem J 53, 577–579 (2019). https://doi.org/10.1007/s11094-019-02040-w

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11094-019-02040-w

Keywords

Navigation