Assessing the Vibrational Frequencies of the Holweide Hospital in the City of Cologne (Germany) by Means of Ambient Seismic Noise Analysis and FE modelling

  • Published:
Natural Hazards Aims and scope Submit manuscript

Abstract

Ambient seismic noise measurements were conducted inside the Holweide Hospital (Cologne) for checking whether its frequencies of vibration fall into the range where soil amplification is expected. If this is the case, damage might increase in case of an earthquake due to an amplified structural response of the building. Two different techniques were used: the ratio between the horizontal and vertical components of the spectra recorded at stations located inside the building and the ratio between the corresponding components of the spectra recorded simultaneously inside the building and at a reference station placed outside. While the former method might be preferred because of less equipment involved, the latter has the advantage of producing more stable results and deleting automatically the influence of the sedimentary cover, which might obscure some eigenfrequencies of vibration of the building. An independently performed finite-element analysis of the hospital showed a good correlation between measured and calculated eigenmodes.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • S. A. Anagnostopoulos K. V. Spiliopoulos (1991) ArticleTitleAn investigation of earthquake induced pounding between adjacent buildings J. Earthq. Eng 21 289–302

    Google Scholar 

  • D. Bindi S. Parolai D. Spallarossa M. Cattaneo (2000) ArticleTitleSite effects by H/V ratio: comparison of two different procedures J. Earthq. Eng 4 97–113

    Google Scholar 

  • R. D. Borcherdt (1970) ArticleTitleEffects of local geology on ground motion near San Francisco bay Bull. Seism. Soc. Am 60 29–61

    Google Scholar 

  • J. M. W. Brownjohn (2002) ArticleTitleAmbient vibration studies for system identification of tall buildings J. Earthq. Eng 32 72–95

    Google Scholar 

  • DIN 4149: 2002, 10 Buildings in German Earthquake Areas - Design Loads, Analysis, and Structural design of buildings, draft (in German), DIN Deutsches Institut für Normung e.V., Berlin.

  • Fäcke, A., Parolai, S., Richwalski, S. M., and Stempniewski, L.: 2005, Assessing the vibrational frequencies of the cathedral of Cologne (Germany) by means of ambient seismic noise analysis, Natural Hazards (in press).

  • D. Fäh F. Kind D. Giardini (2001) ArticleTitleA theoretical investigation of average H/V ratios Geophys. J. Int 145 535–549

    Google Scholar 

  • G. Grünthal D. Mayer-Rosa W. A. Lehnardt (1998) ArticleTitleAbschätzung der Erdbebengefährdung für die D-A-CH Staaten Deutschland, Österreich, Schweiz Bautechnik 10 19–33

    Google Scholar 

  • S. S. Ivanović M. D. Trifunac M. I. Todorovska (2000) ArticleTitleAmbient vibration tests of structures–a review Bull. Ind. Soc. Earthq. Technol 37 165–197

    Google Scholar 

  • C. Lachet P. Y. Bard (1994) ArticleTitleNumerical and theoretical investigations on the possibilities and limitations of the Nakamura’s technique J. Phys. Earth 42 377–397

    Google Scholar 

  • J. Lermo F. J. Chavez-Garcia (1994) ArticleTitleAre microtremors useful in site response evaluation? Bull Seism. Soc. Am 84 1350–1364

    Google Scholar 

  • M. Mucciarelli G. Monachesi (1998) ArticleTitleA quick survey of local amplifications and their correlation with damage observed during the Umbro-Marchesan earthquake of September 26 1997, J. Earthq. Eng 2 1–13

    Google Scholar 

  • M. Mucciarelli G. Monachesi (1999) ArticleTitleThe Bovec (Slovenia) earthquake, April 1998: a preliminary correlation among damage, round motion amplification and building frequencies J. Earthq. Eng 3 317–327

    Google Scholar 

  • Mucciarelli, M., Monachesi, G., and Gallipoli, R.: 1999, In situ measurements of site effects and buildings dynamic behaviour related to damage observed during 9/9/1998 earthquake in southern Italy, In: Proc. ERES 99 Conf. Catania, Catania, Italy, 253–265.

  • M. Mucciarelli P. Contri G. Monachesi G. Calvano M. Gallipoli (2001) ArticleTitleAn empirical method to assess the seismic vulnerability of existing buildings using the HVSR technique Pure Appl. Geophys 158 2635–2647

    Google Scholar 

  • Y. Nakamura (1989) ArticleTitleA method for dynamic characteristics estimations of subsurface using microtremors on the ground surface, Quart. Rept. RTRI Japan 30 25–33

    Google Scholar 

  • Nakamura, Y., Gurler, E. D., Saita, J., Rovelli, A., and Donati, S.: 2000, Vulnerability investigation of roman coliseum using microtremor, In: Proc. 12th World Conference on Earthquake Engineering, Auckland, New Zealand, No. 2660.

  • S. Parolai P. Bormann C. Milkereit (2001) ArticleTitleAssessment of the natural frequency of the sedimentary cover in the Cologne area (Germany) using noise measurements J. Earthq. Eng 5 541–564

    Google Scholar 

  • S. Parolai P. Bormann C. Milkereit (2002) ArticleTitleNew relationships between Vs thickness of the sediments and resonance frequency calculated by means of H/V ratio of seismic noise for the Cologne area (Germany), Bull. Seism. Soc. Am 92 IssueID6 2521–2527

    Google Scholar 

  • Richwalski, S. M., Fäcke, A., Parolai, S., and Stempniewski, L.: 2005, Influence of site and source dependent ground motion scenarios on the safety of long-span bridges in Cologne, Germany, Natural Hazards (in press).

  • P. Wessel W. H. F. Smith (1991) ArticleTitleFree software helps map and display data, EOS Trans. AGU 72 IssueID41 445–446

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Stefano Parolai.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Parolai, S., Fäcke, A., Richwalski, S.M. et al. Assessing the Vibrational Frequencies of the Holweide Hospital in the City of Cologne (Germany) by Means of Ambient Seismic Noise Analysis and FE modelling. Nat Hazards 34, 217–230 (2005). https://doi.org/10.1007/s11069-004-0686-z

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11069-004-0686-z

Keywords

Navigation