Skip to main content
Log in

Detection of carcinoembryonic antigen using functional magnetic and fluorescent nanoparticles in magnetic separators

  • Research Paper
  • Published:
Journal of Nanoparticle Research Aims and scope Submit manuscript

Abstract

We combined a sandwich immunoassay, anti-CEA/CEA/anti-CEA, with functional magnetic (~80 nm) and fluorescent (~180 nm) nanoparticles in magnetic separators to demonstrate a detection method for carcinoembryonic antigen (CEA). Determination of CEA in serum can be used in clinical diagnosis and monitoring of tumor-related diseases. The CEA concentrations in samples were deduced and determined based on the reference plot using the measured fluorescent intensity of sandwich nanoparticles from the sample. The linear range of CEA detection was from 18 ng/mL to 1.8 pg/mL. The detection limit of CEA was 1.8 pg/mL. In comparison with most other detection methods, this method had advantages of lower detection limit and wider linear range. The recovery was higher than 94%. The CEA concentrations of two serum samples were determined to be 9.0 and 55 ng/mL, which differed by 6.7% (9.6 ng/mL) and 9.1% (50 ng/mL) from the measurements of enzyme-linked immunosorbent assay (ELISA), respectively. The analysis time can be reduced to one third of ELISA. This method has good potential for other biomarker detections and biochemical applications.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  • An H, Yuan R, Tang D, Chai Y, Li N (2007) Dual-amplification of antigen–antibody interaction via backfilling gold nanoparticles on 3-mercaptopropyl trimethoxysilane sol–gel functionized interface. Electroanalysis 9:479–486

    Article  Google Scholar 

  • Duffy MJ, van Dalen A, Haglund C, Hansson L, Klapdor R, Lamerz R, Nilsson O, Sturgeon C, Topolcan O (2003) Clinical utility of biochemical markers in colorectal cancer: European group on tumor markers guideline. Eur J Cancer 39:718–727

    Article  CAS  Google Scholar 

  • Farrell S, Ronkainen-Matsuno NJ, Halsall HB, Heineman WR (2004) Bead-based immunoassays with microelectrode detection. Anal Bioanal Chem 379:358–367

    Article  CAS  Google Scholar 

  • Hamley IW (2003) Nanotechnology with soft materials. Angew Chem Int Ed 42:1692–1712

    Article  CAS  Google Scholar 

  • Haugland RP (2002) Handbook of fluorescent probes and research products, 9th edn. Molecular Probes Inc, Eugene, OR, USA

    Google Scholar 

  • He X, Yuan R, Chai Y, Shi Y (2008) A sensitive amperometric immunosensor for carcinoembryonic antigen detection with porous nanogold film and nano-Au/chitosan composite as immobilization matrix. J Biochem Biophys Methods 70:823–829

    Article  CAS  Google Scholar 

  • Kemeny DM (1991) A practical guide to ELISA. Permagon Press, Oxford, UK

    Google Scholar 

  • Kouassi GK, Irudayaraj J (2006) Magnetic and gold-coated magnetic nanoparticles as a DNA sensor. Anal Chem 78:3234–3241

    Article  CAS  Google Scholar 

  • Pan J, Yang Q (2007) Antibody-functionized magnetic nanoparticles for the detection of carcinoembryonic antigen using a flow-injection electrochemical device. Anal Bioanal Chem 388:279–286

    Article  CAS  Google Scholar 

  • Price CP, Newman JD (1997) Principle and practice of immunoassay, 2nd edn. Macmillan Press, Hampshire, UK

    Google Scholar 

  • Trindade T (2001) Nanocrystalline semiconductors: synthesis, properties, and perspectives. Chem Mater 13:3843–3858

    Article  CAS  Google Scholar 

  • Tsai HY, Hsu FH, Lin YP, Fuh CB (2006) Separation method based on affinity reaction between magnetic and nonmagnetic particles for the analysis of particles and biomolecules. J Chromatogr A 1130:227–231

    Article  CAS  Google Scholar 

  • Tsai HY, Hsu CF, Chiu IW, Fuh CB (2007) Detection of c-reactive protein based on immunoassay using antibody-conjugated magnetic nanoparticles. Anal Chem 79:8416–8419

    Article  CAS  Google Scholar 

  • Wu J, Tang J, Dai Z, Yan F, Ju H, Murr NE (2006) A disposable electrochemical immunosensor for flow injection immunoassay of carcinoembryonic antigen. Biosens Bioelectron 22:102–108

    Article  CAS  Google Scholar 

Download references

Acknowledgments

This work was supported by grant NSC-96-2811-260-003 from the National Science Council of Taiwan. The authors would like to thank Ms. S. M. Tsai and Dr. F. C. Cheng for their technical assistances.

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to H. Y. Tsai or C. Bor Fuh.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Supplementary material 1 (PDF 143 kb)

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tsai, H.Y., Chang, C.Y., Li, Y.C. et al. Detection of carcinoembryonic antigen using functional magnetic and fluorescent nanoparticles in magnetic separators. J Nanopart Res 13, 2461–2467 (2011). https://doi.org/10.1007/s11051-010-0138-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11051-010-0138-5

Keywords

Navigation