Introduction

Neodymium iron boron NdFeB (Nd2Fe14B) permanent magnets were developed in 1984 and are regarded as the strongest and the best available magnets on the market until today. They are key components in many high technology and consumer products such as electrical and electronics devices, hard-disk drives, sensors, industrial motors, electric and hybrid vehicles, electric bicycles and scooters, wind turbines, medical imaging and scanners. In order to achieve the climate neutrality, the European Union targets a reduction of greenhouse gas emissions by 60% by 2050 [1]. This objective requires an increase of the electricity production from renewable resources like wind and the use of electric or hybrid vehicles which will need around 1–2 million tons and 150,000 tons of permanent magnets, respectively [2]. The rare earth elements (REE) neodymium (Nd), praseodymium (Pr) and dysprosium (Dy) present in NdFeB magnets are classified together with 37 other elements and 9 substances as critical raw materials (CRMs) by the European Commission due to their economic relevance and supply risk [3]. Actions to ensure a secure and sustainable supply of CRMs are proposed in the European Critical Raw Materials Act [4], one of them concerning the recycling. The different strategies and processes for recycling of spent NdFeB magnets and recover of REE like direct recycling and hydrometallurgical, pyrometallurgical and electrochemical extraction are extensively discussed in [5,6,7]. Efficient recycling requires, at front end, a sorting of the magnets according not only to their type (Ferrite, SmCo, AlNiCo, NFeB, etc.) but also to their content of REEs. A variety of analytical techniques can be used for determination of the REE content in waste flows. Destructive analytical methods, such as Induced Coupled Plasma-Mass/Optical Emission Spectrometry (ICP-MS or -OES) are capable of providing accurate results, necessitating, however, the dissolution of a part of a sample [8]. Moreover, in the case of heterogeneous samples, the results are not representative for the whole sample. X-Ray Fluorescence (XRF) [9] and Laser Induced Breakdown Spectroscopy (LIBS) [10] are non-destructive methods but provide only near-surface information and are not able to identify stacks of materials. Prompt Gamma Neutron Activation analysis (PGNAA) technique with cold or thermal neutrons reaches its performance capabilities due to penetration length limitations of the incident neutron beam in dense materials [11, 12]. Besides, the use of cold neutrons requires complicated instrumentation and is thus not suitable for in-situ industrial applications. Neutron Activation Analysis (NAA) requires access to a research reactor, which, coupled with the timelines of such measurements, is not suitable for the task either. As a result, absence of a consistent and straightforward solution to characterize rapidly all types of magnets and unfold qualitative and quantitative information about the elemental composition of REEs is a critical issue for the magnet recycling industry.

Prompt Gamma Analysis based on Inelastic Neutron Scattering (PGAINS) could be suitable for a rapid determination of the elemental composition of permanent magnets. This method measures the element specific gamma-rays induced by the inelastic scattering of fast neutrons i.e. (n,n′γ) reactions. It may be mentioned here that the energies of these gamma-rays differ from the energies of the gamma-rays produced by neutron capture reactions. The proof of principle of PGAINS has been demonstrated with the FaNGaS (Fast Neutron-induced Gamma-ray Spectrometry) instrument installed at Heinz Maier-Leibnitz Zentrum (MLZ) using the intense fission neutron beam delivered by the beamtube SR 10 of the FRM II reactor (Forschungs-Neutronenquelle Heinz Maier-Leibnitz) [13,14,15,16,17]. In this work, we investigate the detection of neodymium and dysprosium in NdFeB magnet samples by means of numerical simulations in PHITS code using a beam of 2.5 MeV neutrons. The gamma-ray spectra are collected either with a high-resolution HPGe-detector with 50% efficiency or an array of 8 cadmium zinc telluride (CZT) detectors. The results obtained for the two detection systems are used to estimate the basic parameters and counting times for the development of a real measurement system and to perform further optimization of the numerical model in terms of geometrical configuration of the measurement cell and shielding.

Numerical simulation

The numerical simulations are performed with the PHITS code (Particle and Heavy Ion Transport code System, version 3.28) [18] using the JENDL-4.0 [19] nuclear data library. The geometry of the simulation environment is shown in Fig. 1. A disc-shaped magnet sample with a diameter of 2.8 cm and a thickness of 1 cm is fully irradiated with a parallel beam of 2.5-MeV neutrons of same diameter as the sample. The prompt gamma-ray spectra are collected with a high-resolution HPGe detector (Fig. 1) or with an array of 8 cadmium zinc telluride (CZT) detectors (Fig. 1) positioned at 90° relatively to the axis of the neutron beam and close to the sample. The short sample-to-detector distance allows for collecting gamma-ray spectra with a high counting statistics and does not correspond at this point to a real system because of the detector-preamplifier saturation due to very high input count rates. No shielding material is placed between detector and neutron beam. The HPGe detector is analog to that of the FaNGaS spectrometer (50% relative efficiency, energy resolution of 2.2 keV at 1.33 MeV) and simply modelled by a cylindrical germanium crystal with a length of 8.5 cm and a diameter of 6.4 cm. The CZT detector-array is composed of two arrays of 4 CZT detectors placed on each side of the sample. Each individual CZT detector has a surface of 4 × 4 cm2 and a thickness of 1.5 cm. The energy resolution is 2.5% at 661 keV [20]. The distance between the center of the sample and detector surface is 2 cm for the HPGe-detector and 2.4 cm for each CZT-detector. The spectra are collected with 16,384 energy bins and the upper energy threshold set to 9000 keV. Simulations are conducted for NdFeB magnet samples with various neodymium and dysprosium contents (Table 1). The number of primary neutrons is 1010 for each simulation corresponding to a neutron fluence of 1.62 × 109 cm−2 at sample position. The simulated spectra are analyzed with the spectroscopy software Gamma-W (Westmeier GmbH).

Fig. 1.
figure 1

2D view of the PHITS simulation model with the HPGe detector (left) and with the CZT detector-array composed of two arrays of 4 CZT detectors placed on each side of the sample (right) showing the distribution of the neutron fluence in middle plane of the neutron beam

Table 1 Elemental composition of FeNdB magnets according to [21,22,23,24,, 25]

Results

Parts of the simulated spectra of the magnet samples with different neodymium and dysprosium contents are shown in Fig. 2. The production of gamma-rays from fast neutron capture reactions is negligible due to lower cross-sections compared to the (n,n′) reactions. Assignment of the gamma-ray energies which are due to inelastic scattering of fast neutrons to the isotopes is done using data given in [21] and the database NuDat 3.0 [22]. The most intense signature lines of dysprosium, neodymium and iron are labelled in the spectra. Based on the spectra of the HPGe detector, the following interference-free lines are selected: 454 keV (146Nd), 1377 keV (144Nd, 146Nd) and 1575 keV (142Nd) for neodymium, 167 keV (161Dy, 163Dy), 169 keV (164Dy), and 185 keV (162Dy) for dysprosium and 846 keV (56Fe) for iron. In the case of the CZT detector-array, the lines at 167 and 169 keV are not resolved, forming a single peak containing also a contribution of the 165-keV line of 163Dy. The same is observed for the 185-keV line with a contribution of the weak line of 161Dy at 183 keV. The peak at 454 keV includes a contribution of the 448- and 451-keV lines of 146Nd and148Nd, respectively. The net count rates of the aforementioned lines normalized to a neutron emission of 1010 s−1 are given for the HPGe and CZT detector-array in Tables 2 and 3, respectively. The linear relationship between count rate and element mass is shown in Fig. 3 and the resulting correlation coefficients are given in column 9 of Tables 2 and 3. Due to the close distance between sample and detector the total count rate for both detectors is 3 × 108 s−1 for a neutron flux and sample position of 1.62 × 109 cm−2 s−1. This corresponds to the total count rate of 3.8 × 107 s−1 for each CZT detector equipped with its own readout electronics for signal processing.

Fig. 2
figure 2

Linear relationship between the normalized count rates of selected neodymium and dysprosium lines and the element mass for the HPGe-detector (left) and the CZT detector-array (right). The count rates are normalized to a neutron emission of 1010 s−1

Table 2 Net count rate of neodymium, dysprosium and iron lines C normalized to a neutron emission of 1010 s−1 neutrons obtained for the HPGe-detector
Table 3 Net count rate of neodymium, dysprosium and iron lines C normalized to a neutron emission of 1010 s−1 neutrons obtained for the CZT detector-array
Fig. 3
figure 3

Parts of the simulated prompt gamma-ray spectra of magnet samples with different compositions (see Table 1) for the HPGe detector (left) and the CZT detector-array (right). The count rate is normalized to a neutron emission of 1010 s−1

Discussion

Based on the simulation results a rapid determination of neodymium and dysprosium content in FeNdB magnets requires a high fast neutron flux at sample position in conjunction with an optimal sample-to-detector distance in order to avoid saturation of detector electronics. Let′s first consider as 2.5 MeV neutron source a deuterium-deuterium neutron generator with a neutron emission of N0 = 1010 s−1 in 4pi. For a distance between neutron source and sample of L = 30 to 50 cm for example (some optimized shielding material is needed between the neutron source and the detector in the real measurement system [21]) the neutron flux at sample position will be between 3 × 105 and 9 × 105 cm−2 s−1 (N0/4πL2). It means that for reaching the gamma-ray counts obtained in the simulation with a flux of 1.6 × 109 cm−2 s−1 and the close sample-to-detector distance a counting time of between 30 and 90 min will be necessary. This assay time is definitively too long for a characterization of magnets at industrial scale which requires a high sample throughput. An intense fast neutron flux at sample position could be delivered by a compact accelerator based neutron source (CANS) composed of a 5 MeV proton accelerator and a thick beryllium neutron-target. In this case the 9Be(p, xn)9Be reaction produces a total neutron yield of 3.5 × 1012 mA−1 s−1 in 4π sr [22]. At an angle of 0° with respect to the proton beam, the neutron spectrum has a maximum at 2.7 MeV and the neutron yield is 4 × 1011 mA−1 s−1 [22]. Thus, setting the proton beam current to 25 μA will offer a neutron emission of 1010 s−1 towards the sample and a flux at sample position of 1.62 × 109 cm−2 s−1 corresponding to the parameters used in the simulations. In order to avoid saturation of the detector preamplifier the distance between sample and detector must be increase compared to the close counting geometry of the simulations. The total detector count rate decreases by a factor defined as the ratio of the solid angles subtended by the detector at the sample position, Ω(d)/Ω (d0) calculated for the new distance d and the distance d0 set in the simulations. For the HPGe detector d0 is 2.4 cm and Ω(d0) = 2.51 sr. For each CZT detector-array, d0 is 2 cm and Ω(d0) = 3.71 sr. For simplification, the solid angle is calculated assuming the sample as a point source. The inverse value of the solid angle ratio corresponds to the counting time tc needed to obtain the same spectra as the simulated ones i.e. the count rates of the gamma lines given in Tables 2 and 3. The values of d, Ω(d), and tc obtained for total detector count rate of 250 kcps, 500 kcps and 1000 kcps are given in Table 4. Such high-count rates can be handle without considerable degradation of the energy resolution with the adaptive digital pulse processing system including pulse deconvolution developed in [23]. As seen from Table 4, the CZT detector array due to its better geometrical efficiency requires less time to characterize a 42 g NdFeB magnet sample than the HPGe-detector, one main limiting factor for the latter being the input count rate. However, with a better energy resolution HPGe-detectors offers a lower limit of detection. One advantage of CZT detectors is that they are room temperature devices and do not require cooling unlike HPGe detectors. Moreover, recent progress and development in CZT detector technology opens a promising future for application of CZT detectors for such analytical tasks, offering an energy resolution better than 1% at 662 keV [24]. Of course, the time required to characterize a magnet will depend on its mass, size or shape i.e. on its neutron self-shielding and gamma self-absorption and further numerical simulations must be carried out to optimize such as analytical system including also the neutron- and gamma-shielding components.

Table 4 Counting time tc required to generate the spectra simulated for a 42 g magnet with a neutron flux of 1.62 × 109 cm−2 s−1 at various sample-to-detector distances d i.e. various total detector count rates Ctotal

Conclusions

In this work, we explored the possibility of a rapid characterization of NdFeB permanent magnets in view of their sorting/recycling at industrial scale simulating the measurement of prompt gamma-rays induced by inelastic scattering of 2.5 MeV neutrons with the PHITS code. Magnets (mass: 42 g) with various neodymium and dysprosium content were irradiated with an intense neutron beam (1010 s−1) and the gamma-ray spectra recorded with two different detectors, a HPGe detector and two CZT detector-arrays placed close to the sample. For both detectors a very good linear relationship was obtained between the count rates of selected gamma lines of neodymium and dysprosium and the element mass. A rapid characterization of the magnets (interrogation time of about 1 min or less) requires a high neutron flux at sample position that cannot be achieved by using a deuterium-deuterium neutron generator with a neutron emission of 1010 s−1 4π sr. In this case, the time needed to characterize a magnet ranges between 30 and 90 min for a small sample-to-detector distance. A high sample neutron flux can be delivered by a CANS based on a 5 MeV proton accelerator and a thick beryllium target for neutron production via the 9B(p,xn)9Be reaction. With such a neutron source and limiting the input count rate to 500 kcps the characterization of a 42 g magnet could be attained in 6 min with the HPGe detector (distance from sample: 88 cm) and in 1.3 min with the CZT detector-arrays (distance from sample: 36 cm) composed of 8 individual CZT detectors with own readout electronics. The results show the promising potential of the PGAINS technique using a CANS for rapid characterization of magnets of various types and other materials in industrial applications. However, further studies based on numerical simulations are necessary for the design of a real system, including the dynamical range of sample masses that could be assayed, the neutron beam size, the irradiation chamber with neutron beam stop, the neutron and gamma shielding and the optimization of the detector geometry according to the input count rate.