Abstract
A rapid separation method has been developed which allows measurement of plutonium, americium and strontium isotopes in the high active sample from CBRN Training and Testing Centre in Zemianske Kostolany (Slovakia) with high chemical recoveries and effective removal of matrix interferences. This method uses different commercial products stacked AnaLig® Pu-02, AnaLig® Sr-01 and DGA® Resin cartridges from IBC Advanced Technologies and Eichrom Technologies. The method allows rapid separation of plutonium, strontium and americium using a single multi-stage column in the vacuum box (cartridge technology) with rapid flow rates to minimize sample separation time. The 239,240Pu, 238Pu and 241Am were determined by alpha spectroscopy, 90Sr was counted on TRICARB 2900 TR by Cerenkov counting of its progeny 90Y.
Similar content being viewed by others
References
Izatt SR, Bruening RL, Krakowiak KE Izatt RM (2003) The selective separation of anions and cations in nuclear waste using commercially available molecular recognition technology products. In: Proceedings WM 03 Conf, Tuscon, 23–27 Feb 2003
Izatt RM, Bradshaw JS, Bruening RL (1996) Pure Appl Chem 68(6):1237–1241
IBC Advanced Technologies. AnaLig gel data sheet strontium column series SR-01, IBC Advanced Technologies, Inc, 2010
Mitra (ed) (2003) Sample preparation techniques in analytical chemistry. Wiley, New Jersey, 162: 79–112
http://www.ibcmrt.com/anl.html.cit. Accessed 24 May 2012
IBC Advanced Technologies: AnaLig gel data sheet strontium column series SR-01, IBC Advanced Technologies, Inc, 2010
IBC Advanced Technologies: AnaLig gel data sheet plutonium column series PU-02, IBC Advanced Technologies, Inc, 2011
Dulanská S, Remenec B, Mátel Ľ, Galanda D (2011) J Radioanal Nucl Chem 287(3):841–845
Dulanská S, Remenec B, Mátel Ľ, Antalík I (2011) Validation of 239,240Pu, 238Pu separation method using molecular recognition product AnaLig® Pu02 gel and extraction chromatography TRU® resin. J Radioanal Nucl Chem. doi:10.1007/s10967-011-1370-x
Dulanska S, Remenec B, Matel Ľ, Galanda D, Molnár A (2011) J Radioanal Nucl Chem 288:705–708
Dulanská S, Mátel Ľ et al (2011) Validácia stanovenia izotopov plutónia s použitím novej metódy extrakčnej chromatografie. Bezpečnost jaderné energie 19(5/6):172–175
Dulanska S, Remenec B, Matel Ľ, Galanda D, Molnár A (2011) J Radioanal Nucl Chem 288:705–708
Ometáková J, Dulanská S, Mátel Ľ, Remenec B (2011) J Radioanal Nucl Chem 290(2):319–323
Eichrom Industries Inc., http://www.eichrom.com/products/info/tru_resin.cfm. cit. Accessed 24 May 2012
Eichrom Industries Inc., http://www.eichrom.com/products/info/dga_resin.cfm. cit. Accessed 24 May 2012
Sill CW (1987) Nucl Chem Waste Manag 7:201
Hindman FD (1983) Anal Chem 55(14):2460–2461
Dulanská S, Remenec B, Mátel Ľ, Durkot E (2012) J Radioanal Nucl Chem 293:81–85
Acknowledgments
This work was supported by the Slovak Research and Development Agency under the contract No. APVV-20-007105.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Dulanská, S., Antalík, I., Labaška, M. et al. Rapid determination of 239,240Pu, 238Pu, 241Am and 90Sr in high contaminated samples waste using combined SPE sorbents AnaLig® Pu-02, AnaLig® Sr-01 and DGA® Resin. J Radioanal Nucl Chem 295, 1635–1639 (2013). https://doi.org/10.1007/s10967-012-2174-3
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-012-2174-3