Abstract
Samples of l-[S-methyl-11C]methionine prepared by on-column [11C]methylation on a C18 cartridge were analyzed by HPLC under different conditions in order to explain some anomalies observed in the UV-chromatograms. By so doing, two new unlabelled impurities were found and identified as iodide and homocystine. Their amounts are still compatible with the safe human use of the radiotracer solution. Nevertheless, if needed, iodide can be totally removed by elution through an anion-exchange resin, while homocystine can be reduced by either decreasing the amount of precursor used in the synthesis or preventing its air oxidation.
References
Nakada K (2004) The role of methionine PET in oncology. Int Congress Series 1264:88–94
Yamane T, Sakamoto S, Senda M (2010) Clinical impact of 11C-methionine PET on expected management of patients with brain neoplasm. Eur J Nucl Med 37:685–690
Pascali C, Bogni A, Iwata R, Decise D, Crippa F, Bombardieri E (1999) High efficiency preparation of l-[S-methyl-11C]methionine by on-column [11C]methylation on C18 Sep-Pak. J. Labelled Compd Radiopharm 42:715–724
Mitterhauser M, Wadsak W, Krcal A, Schmaljohann J, Eidherr H, Schmid A, Viernstein H, Dudczak R, Kletter K (2005) New aspects on the preparation of [11C]methionine—a simple and fast online approach without preparative HPLC. Appl Radiat Isot 62:441–445
Gomez V, Gispert JD, Amador V, Llop J (2008) New method for routine production of l-[methyl-11C]methionine: in loop synthesis. J Label Compd Radiopharm 51:83–86
Bogni A, Bombardieri E, Iwata R, Cadini L, Pascali C (2003) Stability of l-[S-methyl-11C]methionine solutions. J Radioanal Nucl Chem 256:109–203
Schmitz F, Plenevaux A, Del-fiore G, Lemaire C, Comar D, Luxen A (1995) Fast routine production of l-[11C-methyl]methionine with Al2O3/KF. Appl Radiat Isot 46:893–897
Berridge MS, Cassidy EH, Miraldi F (1995) [11C]Acetate and [11C]methionine: improved syntheses and quality control. Appl Radiat Isot 46:173–175
L-Methionine ([11C]methyl) injection (2008) European Pharmacopoeia 6.0 edn, 1001-1003
Laurie AJ, Lyon SG, Lasser EC (1992) Contrast material iodides: potential effects on radioactive iodine thyroid uptake. J Nucl Med 33:237–238
Product information Pralidoxime Iodide (P.A.M.) Injection (2008) Version 05, Phebra Pty Ltd
Duerre JA, Miller CH (1966) Preparation of l-homocysteine from l-homocysteine thiolactone. Anal Biochem 17:310–315
Korsakov MV, Kisselev MY, Solovyov D, Horti AG, Vasilev DA (1991) Robotic synthesis of [carbon-11]methionine. In: Proceedings of the IVth international workshop on targetry and target chemistry, Villigen, Switzerland, 9–12 September 1991
Mudd SH, Finkelstein JD, Refsum H, Ueland PM, Malinow MR, Lentz SR, Jacobsen DW, Brattstrom L et al (2000) Homocysteine and its disulfide derivatives. Arterioscler Thromb Vasc Biol 20:1704–1706
Ragone R (2002) Homocystine solubility and vascular disease. FASEB J 16:401–404
Acknowledgments
This work was supported by the Project 5‰ “Development of Radiopharmaceuticals”, the AIRC Project “Molecular and Cellular Imaging of Cancer” and the Project PIO INT Ministero Lavoro.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Pascali, C., Bogni, A., Cucchi, C. et al. Detection of additional impurities in the UV-chromatogram of l-[S-methyl-11C]methionine. J Radioanal Nucl Chem 288, 405–409 (2011). https://doi.org/10.1007/s10967-011-0995-0
Received:
Published:
Issue Date: