Skip to main content
Log in

An inter-calibration campaign using various selected Pu spike isotopic reference materials

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

In nuclear safeguards, precise and accurate isotopic analyses are needed for two major elements from the nuclear fuel cycle: uranium and plutonium. This can be achieved by Isotope Dilution Mass Spectrometry (IDMS), which is one of the most reliable analytical techniques for the determination of plutonium amount content to a high level of accuracy. In order to achieve reliable isotope measurements isotopic reference materials with certified amount of plutonium and isotopic composition are required. At the Institute for Reference Materials and Measurements (IRMM) various plutonium spike reference materials for isotopes 239Pu, 240Pu, 242Pu and 244Pu are available. This enabled the setup of an inter-calibration campaign inter-linking selected plutonium spikes on a metrological basis applying state-of-the-art measurement procedures. The aim of this campaign is threefold: firstly to perform measurements on selected plutonium spike isotopic reference materials for quality control purposes, secondly to verify the amount content and the isotopic composition of the recently produced IRMM-1027m large sized dried (LSD) spikes and thirdly to demonstrate IRMM’s measurement capabilities for plutonium analysis via external quality tools. The obtained results using various spike isotopic reference materials will be presented and discussed in this paper. The measurement uncertainties of the IDMS results were calculated according to the guide to the expression of uncertainty in measurement (GUM).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. International Atomic Energy Agency (1970) Treaty on the non-proliferation of nuclear weapons, INFCIRC/140. http://www.iaea.org/Publications/Documents/Infcircs/Others/infcirc140.pdf

  2. International Atomic Energy Agency (1997) Model protocol additional to the agreement(s) between state(s) and the International Atomic Energy Agency for the application of safeguards, INFCIRC/540. http://www.iaea.org/Publications/Documents/Infcircs/1997/infcirc540c.pdf

  3. Jakopič R, Richter S, Kühn S, Aregbe Y (2010) Determination of 240Pu/239Pu, 241Pu/239Pu and 242Pu/239Pu isotope ratios in environmental reference materials and samples from Chernobyl by thermal ionization mass spectrometry (TIMS) and filament carburization. J Anal At Spectrom 25:815–821

    Article  Google Scholar 

  4. Mayer K, Wellum R, (2004) Reference materials for destructive analysis in nuclear safeguards. ESARDA Bull 32:75–81

    Google Scholar 

  5. Joint Committee for Guides in Metrology (2008) Uncertainty of measurement-part 3: guide to the expression of uncertainty in measurement ISO/IEC guide 98-3:2008. http://www.bipm.org/utils/common/documents/jcgm/JCGM_100_2008_E.pdf

  6. Richter S, Goldberg SA (2003) Improved techniques for high accuracy isotope ratio measurements of nuclear material using thermal ionization mass spectrometry. Int J Mass Spectrom 229:181–197

    Article  CAS  Google Scholar 

  7. Callis EL, Abernathey RM (1991) High-precision isotopic analyses of uranium and plutonium by total sample volatilization and signal integration. Int J Mass Spectrom 103:93–105

    Article  CAS  Google Scholar 

  8. Mayer K, Duinslaeger L, Cromboom O, Ottmar H, Wojnowski D, Van der Vegt H (2001) Analytical quality control concept in the euratom on-site laboratories. In: Proceedings symposium on international safeguards, IAEA-SM-367/5/02. http://www-pub.iaea.org/MTCD/publications/PDF/ss-2001/Start.pdf

  9. Verbruggen A, Bauwens J, Eykens R, Jacobsson U, Jakopic R, Kehoe F, Kühn H, Kushigeta Y, Richter S, Aregbe Y (2009) Preparation and certification of IRMM-1027m, large-sized dried (LSD) spike, EUR 24119 EN. http://www.irmm.jrc.be/html/reference_materials_catalogue/catalogue/IRMM_certificates_and_reports/EUR_24119_1027m_report.pdf

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. Jakopič.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jakopič, R., Verbruggen, A., Eykens, R. et al. An inter-calibration campaign using various selected Pu spike isotopic reference materials. J Radioanal Nucl Chem 286, 449–454 (2010). https://doi.org/10.1007/s10967-010-0759-2

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-010-0759-2

Keywords

Navigation