Skip to main content
Log in

New chemical Fricke gel radiation dosimeter

  • Radiation Chemistry
  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

Dosimetric gel is used in several measurements due to its linearity, low cost, and possibility for 3D measurements. This work brings a new possibility to apply the Fricke Xylenol Gel recipe in the diagnostic measurements region. The Fricke Xilenol Gel (FXG) dosimeter is associated with the Fe(II) to Fe(III) oxidation, when irradiated, being the final ion concentration proportional to the absorbed dose. To achieve the scope, the former dosimeter was modified through the benzoic acid addition in the original recipe forming a new dosimeter, the Benzoic Xylenol Gel (BFXG). The results obtained with this new dosimeter demonstrated a higher sensibility for low absorbed dose values, bringing down the absorbed dose inferior limit from 0.1 to 0.006 Gy, that is more adequate for radiodiagnostic absorbed dose measurements. This result shows the possibly of BFXG dosimeter to be used for measurements in the radiodiagnostic region, as for tomography and mammography techniques.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. H. Fricke, S. Morse, Am. J. Roentgenol., 25 (1927) 430.

    Google Scholar 

  2. M. A. Bero, W. B. Gilboy, Nucl. Instr. Meth., B465 (2000) 717.

    Google Scholar 

  3. C. S. G. Calcina, L. N. de Oliveira, C. E. de Almeida, A. de Almeida, Phys. Med. Biol., 52 (2007) 1431.

    Article  Google Scholar 

  4. A. M. F. Caldeira, A. de Almeida, A. M. Neto, M. L. Baesso, A. C. Bento, M. Silva, Nucl. Instr. Meth., A582 (2007) 484.

    Google Scholar 

  5. B. L. Gupta, K. R. Gomathy, Intern. J. Appl. Radiation Isotopes, 25 (1974) 509.

    Article  CAS  Google Scholar 

  6. B. L. Gupta, Rad. Phys. Chem., 67 (2003) 737.

    Article  CAS  Google Scholar 

  7. R. T. Costa, Avaliando a viabilidade do uso do dosímetro Fricke modificado na radioterapia. [Master Thesis — Universidade de São Paulo, FFCLRP/DFM] (2001).

  8. P. C. D. Petchevist, Dosimetria FXGB para caracterização e feixes em radioterapia. [Master Thesis — Universidade de São Paulo, FFCLRP/DFM] (2006).

  9. A. M. F. Caldeira, A. M. Neto, A. C. Bento, M. L. Baesso, M. A. Silva, A. de Almeida, Nucl. Instr. Meth., B261 (2007) 1159.

    Google Scholar 

  10. L. N. de Oliveira, C. S. G. Calcina, M. A. Parada, C. E. de Almeida, A. de Almeida, Braz. Phys. J., 37 (2007) 1141.

    Google Scholar 

  11. H. Zaias, Desenvolvimento de um novo gel e otimização de leitor para dosimetria química. [Master Thesis — Universidade de São Paulo, FFCLRP/DFM] (2006).

  12. R. G. Kelly, K. J. Jordan, J. J. Battista, Med. Phys., 25 (1998), 1741.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. De Almeida.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pirani, L.F., De Oliveira, L.N., Petchevist, P.C.D. et al. New chemical Fricke gel radiation dosimeter. J Radioanal Nucl Chem 280, 259–264 (2009). https://doi.org/10.1007/s10967-009-0508-6

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-009-0508-6

Keywords

Navigation