Abstract
Dosimetric gel is used in several measurements due to its linearity, low cost, and possibility for 3D measurements. This work brings a new possibility to apply the Fricke Xylenol Gel recipe in the diagnostic measurements region. The Fricke Xilenol Gel (FXG) dosimeter is associated with the Fe(II) to Fe(III) oxidation, when irradiated, being the final ion concentration proportional to the absorbed dose. To achieve the scope, the former dosimeter was modified through the benzoic acid addition in the original recipe forming a new dosimeter, the Benzoic Xylenol Gel (BFXG). The results obtained with this new dosimeter demonstrated a higher sensibility for low absorbed dose values, bringing down the absorbed dose inferior limit from 0.1 to 0.006 Gy, that is more adequate for radiodiagnostic absorbed dose measurements. This result shows the possibly of BFXG dosimeter to be used for measurements in the radiodiagnostic region, as for tomography and mammography techniques.
Similar content being viewed by others
References
H. Fricke, S. Morse, Am. J. Roentgenol., 25 (1927) 430.
M. A. Bero, W. B. Gilboy, Nucl. Instr. Meth., B465 (2000) 717.
C. S. G. Calcina, L. N. de Oliveira, C. E. de Almeida, A. de Almeida, Phys. Med. Biol., 52 (2007) 1431.
A. M. F. Caldeira, A. de Almeida, A. M. Neto, M. L. Baesso, A. C. Bento, M. Silva, Nucl. Instr. Meth., A582 (2007) 484.
B. L. Gupta, K. R. Gomathy, Intern. J. Appl. Radiation Isotopes, 25 (1974) 509.
B. L. Gupta, Rad. Phys. Chem., 67 (2003) 737.
R. T. Costa, Avaliando a viabilidade do uso do dosímetro Fricke modificado na radioterapia. [Master Thesis — Universidade de São Paulo, FFCLRP/DFM] (2001).
P. C. D. Petchevist, Dosimetria FXGB para caracterização e feixes em radioterapia. [Master Thesis — Universidade de São Paulo, FFCLRP/DFM] (2006).
A. M. F. Caldeira, A. M. Neto, A. C. Bento, M. L. Baesso, M. A. Silva, A. de Almeida, Nucl. Instr. Meth., B261 (2007) 1159.
L. N. de Oliveira, C. S. G. Calcina, M. A. Parada, C. E. de Almeida, A. de Almeida, Braz. Phys. J., 37 (2007) 1141.
H. Zaias, Desenvolvimento de um novo gel e otimização de leitor para dosimetria química. [Master Thesis — Universidade de São Paulo, FFCLRP/DFM] (2006).
R. G. Kelly, K. J. Jordan, J. J. Battista, Med. Phys., 25 (1998), 1741.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Pirani, L.F., De Oliveira, L.N., Petchevist, P.C.D. et al. New chemical Fricke gel radiation dosimeter. J Radioanal Nucl Chem 280, 259–264 (2009). https://doi.org/10.1007/s10967-009-0508-6
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-009-0508-6