Abstract
Thermal neutron irradiation experiments performed with cellulose-based l-cysteine-treated and untreated Hg standards showed Hg losses of 59–81% for untreated standards but only about a 0.2% loss for treated standards. These results and others for multielement standards showed that Hg loss is highly dependent on total mass and placement of materials in the irradiation vessel and that distribution of volatilized Hg was fairly uniform throughout the sample-containing region of the vessel. Polyethylene trapped volatile Hg much more efficiently than cellulose and a multielement standard containing inorganic Se selectively trapped Hg lost from a co-irradiated multielement standard containing Hg.
Similar content being viewed by others
References
Westermark T, Sjostrand B (1960) Int J Appl Radiat Isot 9:1
Bate LC (1971) Radiochem Radioanal Lett 6(3):1339
McFarland RC (1973) Radiochem Radioanal Lett 16(1):47
Blotcky AJ, Claassen JP, Fung YK, Meade AG, Rack EP (1995) J Radioanal Chem 195(1):109
Verma R, Kumar S, Parthasarathy R (1997) J Radioanal Chem 218(2):189
Takeuchi T, Shinogi M, Mori I (1979) J Radioanal Chem 53(1):81
Anderson DL, Cunningham WC (2008) J Radioanal Chem 276(1):23
Currie LA (1968) Anal Chem 40(1):586
Acknowledgment
The author wishes to thank the members of Reactor Operations staff at the NCNR for their valuable contributions to this work.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Anderson, D.L. Use of l-cysteine for minimization of inorganic Hg loss during thermal neutron irradiation. J Radioanal Nucl Chem 282, 11–14 (2009). https://doi.org/10.1007/s10967-009-0160-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-009-0160-1