Abstract
The 1220 Quantulus is equipped with an 152Eu external source used to determine an external standard quench parameter SQP(E). The relationship between 90Sr/90Y counting efficiency and SQP(E) was found linear in a defined range of SQP(E) values. This function was fixed after many counting experiences made with 90Sr/90Y standards. The sasme equation is used for the measurement of 90Sr in environmental samples. The first goal of this paper is to objectify an overestimation of the SQP(E) when high energetic beta-emitters like 90Y are present (1 to 4% in routine conditions). The second one is to show how this artefact could induce a bias in the calculation of 90Sr activity in environmental samples. The median of this overestimation is estimated around 6%. Another approach using 85Sr standard is suggested to avoid this overestimation. Provided the chemical composition — and thus the quenching — is similar for the two standards, the counting efficiency measured with the 90Sr/90Y standard could be related to the SQP(E) value of the 85Sr standard. Indeed this one appears to be more robust regarding to the range of activity and to the counting time of the external source.
Similar content being viewed by others
References
J. Thomson, in: Advances in Liquid Scintillation Spectrometry, S. Möbius, J. E. Noakes and F. Schönhofer (Eds), LSC 2001, Radiocarbon, Arizona, USA, 2001, p. 65.
P. Cassette, Techniques de l’Ingénieur, Dossier P2552, 2004, p. 10.
Wallac 1220 Quantulus™ Ultra Low Level Liquid Scintillation Spectrometer, Instrument Manual, Wallac, PerkinElmer, 1220-931-07, 2004, p. 3.
L. Kaihola, J. Radioanal. Nucl. Chem., 243 (2000) 313.
Eichrom Technologies, Inc., SRW01 Strontium 89, 90 in Water, rev. 1.4. 2003, 12 p.
L. Kaihola, Nucl. Instr. Meth. Phys. Res., A339 (1994) 295.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Minne, E., Heynen, F. & Hallez, S. Possible overestimation of the external standard quench parameter on Wallac 1220 Quantulus™ with high energetic beta-emitters. J Radioanal Nucl Chem 278, 39–45 (2008). https://doi.org/10.1007/s10967-007-7160-9
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-007-7160-9