Abstract
This paper proposes finite element modelling based optimization of the magnetic flux leakage (MFL) technique to detect outer surface defects in ferromagnetic steam generator tubes. It features optimized design of core, coil, coil current and location of leakage detection sensor as well as prediction of MFL signals. The 3D modelling, simulation and optimization of MFL signals have been performed using COMSOL 4.3a for prediction of leakage fields from defects in tubes. The influence of length, width and depth of defects on the MFL signal is analysed for enhancing the detection reliability and defect sizing.
Similar content being viewed by others
References
Raj, B., Jayakumar, T., Thavasimuthu, M.: Practical Non-destructive Testing, 2nd edn. Narosa Publishing House, New Delhi (1996)
Lynch, A.J.: Magnetic flux leakage robotic pipe inspection: internal and external method. Dissertation, Rice University (2009)
McEvily, A.J.: Failures in inspection procedures: case studies. Eng. Fail. Anal. 11, 167–176 (2004)
Jayakumar, T., Rao, B.P.C., Thirunavukarasu, S., Raj, B.: Development of remote field eddy current technology for structural integrity assessment of steam generators of PFBR. In: Proceedings of 21st International Conference on Structural Mechanics in Reactor Technology (SMiRT 21), November 6–11, vol. 3, pp. 2698–2704. Curran Associates, Inc., New Delhi, Jan 2013
Ivanov, P.A., Zhang, Z., Yeoh, C.H., Udpa, L., Sun, Y., Udpa, S.S., Lord, W.: Magnetic flux leakage modelling for mechanical damage in transmission pipelines. IEEE Trans. Magn. 34, 3020–3023 (1998)
Kikuchi, H., Sato, K., Shimizu, I., Kamada, Y., Kobayashi, S.: Feasibility study of application of MFL to monitoring of wall thinning under reinforcing plates in nuclear power plants. IEEE Trans. Magn. 47(10), 3963–3966 (2011)
Katragadda, G., Lord, W., Sun, Y.S., Udpa, S., Udpa, L.: Alternative magnetic flux leakage modalities for pipe line inspection. IEEE Trans. Magn. 32(3), 1581–1584 (1996)
Pearson, N.R., Boat, M.A., Priewald, R.H., Pate, M.J., Mason, J.S.D.: Practical capabilities of MFL in steel plate inspection. In: 18th World Conference on Non-destructive Testing, April 2012
Li, X.-B., Li, X., Chen, L., Feng, P.-F., Wang, H.-D., Huang, Z.-Y.: Numerical simulation and experiments of magnetic flux leakage inspection in pipeline steel. J. Mech. Sci. Technol. 23, 109–113 (2009)
Rao, B.P.C., Jayakumar, T.: Recent trends in electromagnetic NDE techniques and future directions. In: 18th World Conference on Non-Destructive Testing, April 2012
Atzlesberger, J., GZagar, B.: Magnetic anomaly detection in ferromagnetic material. In: PIERS Proceedings, pp. 130-134. September 2011
Li, M., Lowther, D.A.: The application of topological gradients to defect identification in magnetic flux leakage-type NDT. IEEE Trans. Magn. 46(8), 3221–3224 (2010)
Khodayari-Rostamabad, A., Reilly, J.P., Nikolova, N.K., Hare, J.R., Pasha, S.: Machine learning techniques for the analysis of magnetic flux leakage images in pipeline inspection. IEEE Trans. Magn. 45(8), 3073–3084 (2009)
Sun, Y., Feng, B., Liu, S., Ye, Z., Chen, S., Kang, Y.: A methodology for identifying defects in the magnetic flux leakage method and suggestions for standard specimens. J. Nondestruct. Eval. 34(3), 1–9 (2015)
Singh, W.S., Rao, B.P., Mukhopadhyay, C.K., Jayakumar, T.: Detection of localized damage in water wall tubes of thermal power plants using GMR sensor array based magnetic flux leakage technique. J. Nondestruct. Eval. 34(3), 1–7 (2015)
Acknowledgments
The authors thank the Board of Research in Nuclear Science (BRNS), Department of Atomic Energy, Mumbai for funding the work. Authors also thank Dr. W. Sharat Chandra Singh, NDE Division, Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkamand Mr. T. SenthilKumar, Junior Research Fellow, National Engineering College, Kovilpattifor their help in the experiments and for technical discussions.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Karuppasamy, P., Abudhahir, A., Prabhakaran, M. et al. Model-Based Optimization of MFL Testing of Ferromagnetic Steam Generator Tubes. J Nondestruct Eval 35, 5 (2016). https://doi.org/10.1007/s10921-015-0320-x
Received: