Abstract
In order to monitor electrical activity of the heart during daily life, we present an electrode of a medical instrument system which is able to measure the body surface potential difference by minimizing the electrode distance. The designed electrode is composed of concentric circles. It was made from the basis of the Laplacian equation, and implemented on PCB coated with gold. So that it does not cause the uncomfortable feeling of contact and possible skin troubles which are typical shortcoming of the conventional ECG measurement. The suggested method utilized three concentric circles on FR-4 substrate, so new amplifier design regarding measuring of small biological signal, is considered which has the characteristics of asymmetric input impedance since the area of concentric circular ring electrodes is not identical. Thereby, electrical activity of the heart was obtained successfully. However, its signal quality is a little bit degraded and the motion artifact still remains as a major problem as is in conventional electrocardiography measurement. Certainly stable measurement setup was needed to reduce the motion artifact originated from variation in static electricity between skin and electrode interfaces.
Similar content being viewed by others
References
Webster, J. G., Medical instrumentation application and design. Wiley, New York, 1998.
Hjorth, B., An on-line transformation of EEG scalp potentials into orthogonal source derivation. Electroencephalogr. Clin. Neurophysiol. 39, 526–530, 1975.
He, B., and Cohen, R. J., Body surface ECG Laplacian mapping. IEEE Trans. Biomed. Eng. BME-39, 1179–1191, 1992.
Bergey, G. E., Squires, R. D., and Sipple, W. C., Electrocardiogram recording with pasteless electrode. IEEE Trans. Biomed. Eng. BME-18(3), 206–211, 1971.
Burke, M. J., and Gleeson, D. T., A micropower dry-electrode ECG preamplifier. IEEE Trans. Biomed. Eng. 47(2), 155–162, 2000.
Hill, O. W., and Khandpur, R. S., The performance of transistor ECG amplifier. World Medical Instruments. 7(5), 12–22, 1969.
Acknowledgments
This work was supported by the Korea Research Foundation Grant funded by the Korean Government (MOEHRD) (The Regional Research Universities Program/Chungbuk BIT Research-oriented University Consortium).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Lee, JW., Lee, KH., Lee, YJ. et al. Reusable Electrical Activity of the Heart Monitoring Patch for Mobile/Ubiquitous Healthcare. J Med Syst 33, 41–46 (2009). https://doi.org/10.1007/s10916-008-9162-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10916-008-9162-8