Temporal Gain Correction for X-ray Calorimeter Spectrometers

  • Published:
Journal of Low Temperature Physics Aims and scope Submit manuscript

Abstract

Calorimetric X-ray detectors are very sensitive to their environment. The boundary conditions can have a profound effect on the gain including heat sink temperature, the local radiation temperature, bias, and the temperature of the readout electronics. Any variation in the boundary conditions can cause temporal variations in the gain of the detector and compromise both the energy scale and the resolving power of the spectrometer. Most production X-ray calorimeter spectrometers, both on the ground and in space, have some means of tracking the gain as a function of time, often using a calibration spectral line. For small gain changes, a linear stretch correction is often sufficient. However, the detectors are intrinsically non-linear and often the event analysis, i.e., shaping, optimal filters etc., add additional non-linearity. Thus for large gain variations or when the best possible precision is required, a linear stretch correction is not sufficient. Here, we discuss a new correction technique based on non-linear interpolation of the energy-scale functions. Using Astro-H/SXS calibration data, we demonstrate that the correction can recover the X-ray energy to better than 1 part in 10\(^{4}\) over the entire spectral band to above 12 keV even for large-scale gain variations. This method will be used to correct any temporal drift of the on-orbit per-pixel gain using on-board calibration sources for the SXS instrument on the Astro-H observatory.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. D. McCammon et al., ApJ 576, 188–203 (2002)

    Article  ADS  Google Scholar 

  2. K. Mitsuda et al., J. Low Temp. Phys. 167, 795 (2012)

    Article  ADS  Google Scholar 

  3. J.W. den Herder et al., Proc. SPIE 8443 2012, 84432B–84432B-12 (2012)

    Article  Google Scholar 

  4. A.E. Szymkowiak, R.L. Kelley, S.H. Moseley, C.K. Stahle, J. Low Temp. Phys. 93, 281–285 (1993)

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to F. S. Porter.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Porter, F.S., Chiao, M.P., Eckart, M.E. et al. Temporal Gain Correction for X-ray Calorimeter Spectrometers. J Low Temp Phys 184, 498–504 (2016). https://doi.org/10.1007/s10909-016-1503-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10909-016-1503-2

Keywords

Navigation