Abstract
The KU Leuven pulsed magnet facility was established in the sixties by the late Prof. A. Van Itterbeek (Van Itterbeek et al., Appl. Sci. Res., 18:105, 1967, Van Itterbeek et al., Les Champs Magnétiques Intenses, vol. 379, 1966). During the period 1972–1997 the laboratory was directed by Prof. F. Herlach (Witters and Herlach, J. Phys. D, Appl. Phys., 16:255, 1983, Li and Herlach, Meas. Sci. Technol., 6:1035, 1995, Herlach et al., Physica B, 201:542, 1994) who continuously developed the facility further along two lines: improved pulsed-field-coil design and enhanced capabilities for experimentation. From 1998 on, the facility is lead by Prof. V.V. Moshchalkov, in close collaboration with Prof. E.F. Herlach and Prof. J. Vanacken. Recently, the laboratory has been completely renewed; its present configuration is based on the former installation of the High Field Magnet Laboratory at the Radboud University Nijmegen (the Netherlands) (Rosseel et al., IEEE Trans. Appl. Supercond., 16:1664, 2006), which was originally developed in collaboration with the KU Leuven spin-off company METIS (http://www.metis.be/).
Similar content being viewed by others
References
A. Van Itterbeek, W. Van Driessche, I. De Grave, Appl. Sci. Res. 18, 105 (1967)
A. Van Itterbeek, W. Van Driessche, I. De Grave, H. Myncke, Les Champs Magnétiques Intenses, vol. 379 (1966)
J. Witters, F. Herlach, J. Phys. D, Appl. Phys. 16, 255 (1983)
L. Li, F. Herlach, Meas. Sci. Technol. 6, 1035 (1995)
F. Herlach, R. Bogaerts, I. Deckers, G. Heremans, L. Li, G. Pitsi, J. Vanacken, L. Van Bockstal, A. Van Esch, Physica B 201, 542 (1994)
K. Rosseel, P.A.J. Dolron, L.P. Nelemans, U. Zeitler, J.A.A.J. Perenboom, S.A.J. Wiegers, J.C. Maan, IEEE Trans. Appl. Supercond. 16, 1664 (2006)
M. Vander Cammen, KU Leuven, Direction Technical Services, Division Laboratories. Private communications
L. Li, F. Herlach, J. Phys. D, Appl. Phys. 31, 1320 (1998)
T. Peng, C.L. Gu, K. Rosseel, J. Vanacken, F. Herlach, Meas. Sci. Technol. 16, 562 (2005)
T. Peng, L. Li, J. Vanacken, F. Herlach, IEEE Trans. Appl. Supercond. 18, 1509 (2008)
E. Haanappel, Digital Lock-in, LNCMP, Toulouse. Personal communication
A.S. Lagutin, J. Vanacken, N. Harrison et al., Rev. Sci. Instrum. 66, 4267 (1995)
Acknowledgements
The authors wish to express their sincere gratitude to the Methusalem funding by the Flemish government, to J.-C. Maan of the Radboud University Nijmegen as well as to L. Liang of the Wuhan National High Magnetic Field Center for their support to the renewal of the KU Leuven high field facility.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Vanacken, J., Peng, T., Perenboom, J.A.A.J. et al. The Renewed KU Leuven Pulsed Field Facility. J Low Temp Phys 170, 553–561 (2013). https://doi.org/10.1007/s10909-012-0647-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10909-012-0647-y