Abstract
This article explains the basic principles of FLCS, a genuine fusion of Time-Correlated Single Photon Counting (TCSPC) and Fluorescence Correlation Spectroscopy (FCS), using common terms and minimum mathematics. The usefulness of the method is demonstrated on simple FCS experiments. The method makes possible to separate the autocorrelation function of individual components of a mixture of fluorophores, as well as purging the result from parasitic contributions like scattered light or detector afterpulsing.
Similar content being viewed by others
References
Böhmer M, Wahl M, Rahn H-J, Erdmann R, Enderlein J (2002) Time-resolved fluorescence correlation spectroscopy. Chem Phys Lett 353(5–6):439–445
Benda A, Hof M, Wahl M, Patting M, Erdmann R, Kapusta P (2005) TCSPC upgrade of a confocal FCS microscope. Rev Sci Instrum 76(3):033106
Enderlein J, Gregor I,(2005) Using fluorescence lifetime for discriminating detector afterpulsing in fluorescence-correlation spectroscopy. Rev Sci Instrum 76(3):033102
Meseth U, Wohland Th, Rigler R, Vogel H (1999), Resolution of fluorescence correlation measurements. Biophys J 76(3):1619–1631
Enderlein J, Erdmann R (1997) Fast fitting of multi-exponential decay curves. Opt Commun 134(1–6):371–378
Wahl M, Koberling F, Patting M, Rahn H-J, Erdmann R (2004) Time-resolved confocal fluorescence imaging and spectroscopy system with single molecule sensitivity and sub-micrometer resolution. Curr Pharm Biotechnol 5(3):299–308
Böhmer M, Enderlein J (2003) Fluorescence spectroscopy of single molecules under ambient conditions: Methodology and technology. Chem Phys Chem 4(8):792-808
Böhmer M, Pampaloni F, Wahl M, Rahn H-J, Erdmann R, Enderlein J (2001) Time-resolved confocal scanning device for ultrasensitive fluorescence detection. Rev Sci Instrum 72(11):4145–4152
Wahl M, Gregor I, Patting M, Enderlein J (2003), Fast calculation of fluorescence correlation data with asynchronous time-correlated single-photon counting. Opt Expr 11(26):3583–3591
Lamb DC, Schenk A, Röcker C, Scalfi-Happ C, Nienhaus GU (2000) Sensitivity enhancement in fluorescence correlation spectroscopy of multiple species using time-gated detection. Biophys J 79(2):1129–1138
Benda A, Fagulova V, Deyneka A, Enderlein J, Hof M (2006) Fluorescence lifetime correlation spectroscopy combined with lifetime tuning: New perspectives in supported phospholipid bilayer research. Langmuir 22(23):9580–9585
Acknowledgment
A.B. and M.H. acknowledge financial support by the Ministry of Education and Sport of the Czech Republic via grant LC06063.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kapusta, P., Wahl, M., Benda, A. et al. Fluorescence Lifetime Correlation Spectroscopy. J Fluoresc 17, 43–48 (2007). https://doi.org/10.1007/s10895-006-0145-1
Received:
Accepted:
Published:
Issue Date: