Analysis of the Ear Pulse Oximeter Waveform

  • Published:
Journal of Clinical Monitoring and Computing Aims and scope Submit manuscript

Abstract

Objective: For years researchers have been attempting to understand the relationship between central hemodynamics and the resulting peripheral waveforms. This study is designed to further understanding of the relationship between ear pulse oximeter waveforms, finger pulse oximeter waveforms and cardiac output (CO). It is hoped that with appropriate analysis of the peripheral waveforms, clues can be gained to help to optimize cardiac performance. Methods. Part 1: Studying the effect of cold immersion test on plethysmographic waveforms. Part 2: Studying the correlation between ear and finger plethysmographic waveforms and (CO) during CABG surgery. The ear and finger plethysmographic waveforms were analyzed to determine amplitude, width, area, upstroke and downslope. The CO was measured using continuous PA catheter. Using multi-linear regression, ear plethysmographic waveforms, together with heart rate (HR), were used to determine the CO Agreement between the two methods of CO determination was assessed. Results. Part 1: On contralateral hand immersion, all finger plethysmographic waveforms were reduced, there was no significant change seen in ear plethysmographic waveforms, except an increase in ear plethysmographic width. Part 2: Phase1: Significant correlation detected between the ear plethysmographic width and other ear and finger plethysmographic waveforms. Phase 2: The ear plethysmographic width had a significant correlation with the HR and CO. The correlation of the other ear plethysmographic waveforms with CO and HR are summarized (Table 5). Multi-linear regression analysis was done and the best fit equation was found to be: CO = 8.084 − 14.248 × Ear width + 0.03 ×HR+ 92.322 × Ear down slope+0.027 × Ear Area Using Bland & Altman, the bias was (0.05 L) but the precision (2.46) is large to be clinically accepted. Conclusion. The ear is relatively immune to vasoconstrictive challenges which make ear plethysmographic waveforms a suitable monitor for central hemodynamic changes. The ear plethysmographic width has a good correlation with CO.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Vincent JL. The pulmonary artery catheter: Twenty years of use. Clin Intensive Care 1990; 4: 244–248.

    Google Scholar 

  2. Connors AF Jr, Speroff T, Dawson NV, et al. The effectiveness of right heart catheterization in the initial care of critically ill patients: SUPPORT Investigators. JAMA 1996; 276: 889–897.

    Article  PubMed  Google Scholar 

  3. Dalen JE, Bone RC. Is it time to pull the pulmonary artery catheter? JAMA 1996; 276: 916–918.

  4. Kelleher JF. Pulse oximetry. J Clin Monit 1989; 5: 37–62.

    Article  PubMed  CAS  Google Scholar 

  5. Nijboer JA, Dorlas JC, Mahieu HF. Photoelectric plethy- smography-some fundamental aspects of the reflection and transmission method. Clin Phys Physiol Meas 1989; 2: 205–215.

    Article  Google Scholar 

  6. Challoner AVJ. Photoelectric plethysmography for estimating cutaneous blood flow. In: P. Rolfe, ed. Noninvasive physiologic measurements. London: Academic Press, 1979: 125–51.

  7. Clayton DG, Webbe RK, Ralston AC, et al. A comparison of performance of twenty pulse oximeters under conditions of poor perfusion. Anaesthesia 1991; 46: 3–10.

    Article  PubMed  CAS  Google Scholar 

  8. Bhargava M, Pothula S. Improvement of pulse oximetry signal by Emla cream. Anesth Analg 1998; 86: 915.

    Google Scholar 

  9. Barker SJ. ‘Motion resistant’ pulse oximetry: a comparison of new and old models. Anesth Analg 2002; 95: 967–972.

    Article  PubMed  Google Scholar 

  10. Redford D, Lichtenthal P, Barker SA clinical comparison of pulse oximeter sensor sites in the pediatric surgical patient: ear, nose, lip and forehead Anesthesiology 2004; 101: A595.

  11. Nijboer JA, Dorlas JC. Comparison of plethysmograms taken from finger and pinna during anaesthesia. Br J Anaesth 1985; 57: 531–34.

    Article  PubMed  CAS  Google Scholar 

  12. Hetzman AB. The blood supply of various skin area as estimated by the photoelectric plethysmograph. Am J Physiol 1938; 124: 238–40.

    Google Scholar 

  13. Roizen MF, Horrigan RW, Frazer BM. Anesthetic doses blocking adrenergic (stress) and cardiovascular responses to incision: MAC BAR. Anesthesiology 1981; 54: 390–8.

    Article  PubMed  CAS  Google Scholar 

  14. Awad AA, Ghobashy MAM, Ouda W, et al. Different responses of ear and finger pulse oximeter waveform to cold pressor test. Anesth. Analg 2001; 92: 1483–1486.

    Article  PubMed  CAS  Google Scholar 

  15. Ornstein E, Eideman L, Drenger B, et al. Systolic pressure variation predicts the response to a cute blood loss. J Clin Anesth 1998; 10: 137–40.

    Article  PubMed  CAS  Google Scholar 

  16. Shamir M, Eideman LA, Floman Y, Kaplan L, Pizov R. Pulse oximetry plethysmographic waveform during changes in blood volume. Br J Anaesth 1999; 82(2): 178–181.

    PubMed  CAS  Google Scholar 

  17. Yamakage M, Itoh T, Jeong SW, Namiki A. Variation of “pulse amplitude” measured by a pulse oximeter may help predict intravascular volume. Can J Anesth 2005; 52(2): 207–208.

    Article  PubMed  Google Scholar 

  18. Gesquiere MJ, Awad AA, Shelley KH, et al. Can ear plethysmography detect moderate blood loss in healthy non-intubated volunteers? Anesthesiology 2004; 101: A180.

    Google Scholar 

  19. Awad AA, Ghobashy MAM, Stout RG, et al. How does the plethysmogram derived from the pulse oximeter relate to arterial blood pressure in CABG? Anesth Analg 2001; 93: 1466–1471.

    Google Scholar 

  20. Nelson LD. The new pulmonary artery catheters: Continuous venous oximetry, right ventricular ejection fraction and continuous cardiac output. New Horiz 1997; 5: 251–258.

    PubMed  CAS  Google Scholar 

  21. Bland JM, Altman DG. Measurement in medicine: The analysis of method comparison studies. Statistician 1983; 32: 307–317.

    Article  Google Scholar 

  22. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307–310.

    PubMed  CAS  Google Scholar 

  23. Dassel ACM, Graaff R, Meijer A, Zijlstra WG, Aarnoudse JG. Reflectance pulse oximetry at the forehead of newborns; the influence of varying pressure on the probe. J Clin Monit 1996; 12: 421–428.

    Article  PubMed  CAS  Google Scholar 

  24. Pollard V, Prough D, DeMeleo AE, Deyo DJ, Uchida T, Stoddart HF. Validation in volunteers of a near infrared spectroscope for monitoring brain oxygenation in vivo. Anesth Analg 1996; 82: 269–277.

    Google Scholar 

  25. Lennmarken C, Vegfors M. Advances in pulse oximetry (review article). Curr Opin Anaesthesiol 1998; 11(6): 639–644.

    Article  PubMed  CAS  Google Scholar 

  26. Lefkowitz RJ, Hoffman BB, Taylor P. Neurotransmission. In: Hardman JG, Limbird LE, Molinoff PB et al. (eds.) Goodman Gillman's The pharmacological basis of therapeutics. 9th ed., McGraw-Hill, New York, 1996; 106–110.

  27. Weissler AM, Harris WS, Schoenfeld CD. Systolic time intervals in heart failure in man. Circulation 1968; 37: 149–59.

    PubMed  CAS  Google Scholar 

  28. Weissler AM, Harris WS, Schoenfeld CD. Bedside techniques for the evaluation of ventricular function in man. Am J Cardiol 1969; 23: 577–583.

    Article  PubMed  CAS  Google Scholar 

  29. Hirschl MM, Binder M, Gwechenberger M, et al. Non invasive assessment of cardiac output in critically ill patients by analysis of the finger blood pressure waveform. Crit Care Med 1997; 25: 1909–1914.

    Article  PubMed  CAS  Google Scholar 

  30. Jubran A. Pulse oximetry. Crit Care 1999; Vol 3 (No 2): [review] 11–17.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kirk H. Shelley MD, PhD.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Awad, A.A., Stout, R.G., Ghobashy, M.A.M. et al. Analysis of the Ear Pulse Oximeter Waveform. J Clin Monit Comput 20, 175–184 (2006). https://doi.org/10.1007/s10877-006-9018-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10877-006-9018-z

Key words

Navigation