Abstract
Ionomeric polymer transducers are electromechanical actuators fabricated from ion-exchange membranes that have been surface plated with conductive metal. In this paper we discuss a series of experiments that characterize the electromechanical actuation response of three families of ionomers: Nafion (a product of DuPont), BPSH (sulfonated poly(arylene ether sulfone)) and PATS (poly(arylene thioether sulfone)). The first polymer is commercially-available while the second and third polymers are synthesized by the direct polymerization of sulfonated monomers in our lab. The mechanical properties and actuation response of Nafion-117, BPSH, and PATS of varying ionic content are studied in the Lithium cation form. The strain response of the materials varies from 50 μ strain/V to 750 μ strain/V at 1Hz. A linear correlation was found between the strain response and the capacitance of the material. This correlation was independent of the polymer composition and the plating parameters. All of the ionomers analyzed in this work exhibited a strain-to-charge response between 9 \(\frac{\rm \mu strain}{\frac{C}{\rm m^2}}\) and 15 \(\frac{\rm \mu strain}{\frac{C}{\rm m^2}}\). Due to the fact that the low-frequency capacitance of an ionomer is strongly related to charge accumulation at the blocking electrodes, this correlation suggests a strong relationship between surface charge accumulation and mechanical deformation in ionomeric actuators.
Similar content being viewed by others
References
K. OGURO, Y. KAWAMI and H. TAKENAKA, J. Microm. Soc. 5 (1992) 27.
M. SHAHINPOOR, Y. BAR-COHEN, J. SIMPSON and J. SMITH, Smart Mater. and Struct. 7(6) (1998) R15.
P. DE GENNES, K. OKUMURA, M. SHAHINPOOR and K. J. KIM, Europhys. Lett. 50(4) (2000) 513.
K. M. NEWBURY and D. J. LEO, J. Intell. Mater. Syst. Struct. 13(1) (2002) 51.
Idem., ibid. 14(6) (2003) 333.
Idem., ibid. 14(6) (2003) 343.
S. NEMAT-NASSER and J. LI, “Electromechanical Response of Ionic Polymer Metal Composites,” in Proceedings of the SPIE, (2000) Vol. 3987, p. 82.
K. FARINHOLT and D. LEO, “Modeling of Electromechanical Charge Sensing in Ionic Polymer Transducers.” To appear in Mechanics of Materials (2002).
S. NEMAT-NASSER, J. Appl. Phy. 92(5) (2002) 2899.
S. NEMAT-NASSER and Y. WU, ibid., 93(9) (2003) 5255.
K. ASAKA, N. FUJIWARA, K. OGURO, K. ONISHI and S. SEWA, J. Electroan. Chem. 505 (2001) 24.
V. V. DANIEL, “Dielectric Relaxation” (Academic Press 1967).
K. MAURITZ and H. YUN, ibid. 21 (1988) 2738.
K. MAURITZ and R. FU, ibid. 21 (1988) 1324.
K. MAURITZ, ibid. 22 (1989) 4483.
B. CAHAN and J. WAINWRIGHT, J. Electrochem. Soc., 140(12) (1993) L185.
J. FONTANELLA, M. MCLIN, M. WINTERSGILL, J. CALAME and S. GREENBAUM, Solid State Ion. 66 (1993) 1.
M. C. WINTERSGILL and J. J. FONTANELLA, Electrochimica Acta 43 (1997) 1533.
F. WANG, M. HIKNER, Y. KIM, T. ZAWODZINSKI and J. MCGRATH, J. Membr. Sci 197 (2002) 231.
K. WILES, V. BHANU, F. WANG and J. E.MCGRATH, Polym. Preprints 43(2) (2002) 993.
Y. KIM, L. DONG, M. HICKNER, T. GLASS, V. WEBB and J. MCGRATH, Macromolecules 36(17) (2003).
K. J. KIM and M. SHAHINPOOR, Smart Mater. Struct. 12 (2003) 65.
K. OGURO, N. FUJIWARA, K. ASAKA, K. ONISHI and S. SEWA, “Polymer electrolyte actuator with gold electrodes,” in Proceedings of the SPIE, (1999) Vol. 3669, p. 63.
J. W. FRANKLIN, “Electromechanical Modeling of Encapsulated Ionic Polymer Transducers,” Masters Thesis Virginia Tech, 2003.
S. NEMAT-NASSER and C. W. THOMAS, in Electroactive Polymer Actuators as Artificial Muscles (SPIE Press, Bellingham, WA, 2001) Chapt. 6, p. 139.
K. ASAKA, N. FUJIWARA, K. OGURO, K. ONISHI and S. SEWA, ibid. 505 (2001) 24.
M. HICKNER, Y. KIM, F. WANG, T. ZAWODZINSKI and J. MCGRATH, in Proceedings of the American Society for Composites, Sixteenth Technical Conference (2001) p. 323.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Akle, B.J., Leo, D.J., Hickner, M.A. et al. Correlation of capacitance and actuation in ionomeric polymer transducers. J Mater Sci 40, 3715–3724 (2005). https://doi.org/10.1007/s10853-005-3312-x
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s10853-005-3312-x