Diode laser cyclophotocoagulation in Indian eyes: efficacy and safety

  • Original Paper
  • Published:
International Ophthalmology Aims and scope Submit manuscript

Abstract

Diode laser cyclophotocoagulation (DLCP) has emerged as a time-tested procedure for end-stage glaucoma with fewer complications. By means of this study, we have evaluated its wide indications, its efficacy, and safety in darkly pigmented Asian Indian eyes. Ninety-one eyes with uncontrolled glaucoma presenting to glaucoma clinic of a tertiary care center over a period of 6 years were scheduled for DLCP. The semiconductor diode laser with a G probe was used with laser energy delivered about 1.5 mm behind the surgical limbus. The extent of clock hours of laser application was determined by pretreatment intraocular pressure (IOP) and superior area was spared in cases where future filtration surgery was contemplated. The DLCP was repeated earliest at 1 month in case of non-response and a maximum of three laser procedures were performed for any patient. Ninety-one eyes of 89 patients (40 males, 49 females) were included. Common indications included secondary glaucoma (37.3 %), failed trabeculectomies (27.4 %), angle closure glaucoma (17.5 %), etc. Laser power delivered ranged from 990 to 1800 mW, (mean 1396 + 182.14 mW) with an average of 17 spots. Patients improved from pretreatment IOP of 38.18 + 8.96 mmHg (range 20.6–64) to post treatment IOP of 17.86 + 7.75 mmHg (range 10–42). Qualified success was defined as final IOP of 20 mm Hg or less on topical medications that could be achieved in 70 % eyes with one or repeat treatment. Pre op visual acuity ranged from PL+ to 6/18 showing a slight improvement to PL+ to 6/12 post op. A 58.5 % reduction of IOP was noted. No incidence of serious complications was noted during follow-up ranging from 9 months to 3 years. DLCP is an effective and safe tool to be used in Indian population for control of IOP. It can be safely used as a primary modality to bring IOP to permissible levels before trabeculectomy.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Walton DS, Grant WM (1970) Penetrating cyclodiathermy for filtration. Arch Ophthalmol 83:47–48

    Article  CAS  PubMed  Google Scholar 

  2. Berens C, Sheppard LB, Duel AB Jr (1949) Cycloelectrolysis for glaucoma. Trans Am Ophthalmol Soc 47:364

    CAS  PubMed  PubMed Central  Google Scholar 

  3. Caprioli J, Strang SL, Spaeth GL et al (1985) Cyclocryotherapy in treatment of advanced glaucoma. Ophthalmology 92:947–953

    Article  CAS  PubMed  Google Scholar 

  4. Bellows AR, Grant WM (1978) Cyclocryotherapy of chronic open angle glaucoma in aphakic eyes. Am J Ophthalmol 85:615–621

    Article  CAS  PubMed  Google Scholar 

  5. Mandal Subrata, Gadia Ritu, Ashar Jatin (2009) Diode laser cyclophotocoagulation. J Curr Glaucoma Pract 3(2):47–59

    Article  Google Scholar 

  6. Mastrobattista JM, Luntz M (1996) Ciliary body ablation: where are we and how did we get here. Surv Ophthalmol 41:193–213

    Article  CAS  PubMed  Google Scholar 

  7. Bietti G (1950) Surgical intervention on the ciliary body. New trends for the relief of glaucoma. JAMA 142:889–897

    Article  CAS  Google Scholar 

  8. Schlote T (2008) Cyclodestructive procedures. In: Surgical management of inflammatory eye disease. Springer, Berlin, pp 193–200

    Chapter  Google Scholar 

  9. Lam S, Tessler HH, Lam BL, Wilensky JT (1992) High incidence of sympathetic ophthalmia after contact and noncontact neodymium: YAG cyclotherapy. Ophthalmology 99:1818–1822

    Article  CAS  PubMed  Google Scholar 

  10. Vogel A, Dlugos C, Nuffer R, Birngruber R (1991) Optical properties of human sclera, and their consequences for trans-scleral laser applications. Lasers Surg Med 11:331–340

    Article  CAS  PubMed  Google Scholar 

  11. Grueb M, Rohrbach JM, Bartz-Schmidt KU, Schlote T (2006) Transscleral diode laser cyclophotocoagulation as primary and secondary surgical treatment in primary open-angle and pseudoexfoliatve glaucoma. Long-term clinical outcomes. Graefes Arch Clin Exp Ophthalmol 244(10):1293–1299

    Article  PubMed  Google Scholar 

  12. Kirwan JF, Shah P, Khaw PT (2002) Diode laser cyclophotocoagulation role in the management of refractory pediatric glaucomas. Ophthalmology 109:316–323

    Article  PubMed  Google Scholar 

  13. Igzi B, Demirici H, Demirici FY, Turker G (2001) Diode laser cyclophotocoagulation in refractory glaucoma:comparison between pediatric and adult glaucomas. Ophthalmic Surg Lasers 32:100–107

    Google Scholar 

  14. Aung T, Tow SL, Yap EY, Chan SP, Seah SK (2000) Trabeculectomy for acute primary angle closure. Ophthalmology 107(7):1298–1302

    Article  CAS  PubMed  Google Scholar 

  15. Speaker MG, Guerriero PN, Met JA, Coad CT, Berger A, Marmor M (1991) A case-control study of risk factors for intraoperative suprachoroidal expulsive hemorrhage. Ophthalmology 98(2):202–209

    Article  CAS  PubMed  Google Scholar 

  16. Bloom PA, Tsai JC, Sharma K (1997) “Cyclodiode”. trans-scleral diode laser cyclophotocoagulation in the treatment of advanced refractory glaucoma. Ophthalmology 104:1508–1519

    Article  CAS  PubMed  Google Scholar 

  17. Mehta R, Puthuran G, Krishnadas R, Mahalakshmi R (2006) Efficacy of transscleral diode laser cyclophotocoagulation for refractory glaucoma in a south Indian population. Asian J Ophthalmol 8:232–235

    Google Scholar 

  18. Kaushik S, Pandav SS, Jain R, Bansal S, Gupta A (2008) Lower energy levels adequate for effective transscleral diode laser cyclophotocoagulation in Asian eyes with refractory glaucoma. Eye (Lond) 22(3):398–405

    Article  CAS  Google Scholar 

  19. Schlote T, Grüb M, Kynigopoulos M (2008) Long-term results after transscleral diode laser cyclophotocoagulation in refractory posttraumatic glaucoma and glaucoma in aphakia. Graefe’s Arch Clin Exp Ophthalmol 246:405–410

    Article  Google Scholar 

  20. Schlote T, Derse M, Rassmann K, Nicaeus T, Dietz K, Thiel HJ (2001) Efficacy and safety of contact transscleral diode laser cyclophotocoagulation for advanced glaucoma. J Glaucoma 10(4):294–301

    Article  CAS  PubMed  Google Scholar 

  21. Bock CJ, Freedmann SF, Buckley EG, Shields MB (1997) Transscleral diode laser cyclophotocoagulation for refractory pediatric glaucomas. J Pediatr Ophthalmol Strabismus 34:235–239

    CAS  PubMed  Google Scholar 

  22. Azuara-Blanco A, Dua HS (1999) Malignant glaucoma after diode laser cyclophotocoagulation. Am J Ophthalmol 127(4):467–469

    Article  CAS  PubMed  Google Scholar 

  23. Kumar H, Gupta S, Agarwal A (2008) Corneal edema following diode laser cyclophotocoagulation in an eye with secondary glaucoma. Indian J Ophthalmol 56(4):317–318

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgments

No grant has been received for the study.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kirti Singh.

Ethics declarations

Conflict of interest

The authors declare that they have no financial involvement or conflict of interest with the subject of this study.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Singh, K., Jain, D. & Veerwal, V. Diode laser cyclophotocoagulation in Indian eyes: efficacy and safety. Int Ophthalmol 37, 79–84 (2017). https://doi.org/10.1007/s10792-016-0228-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10792-016-0228-1

Keywords

Navigation