Digital fundus photography, commonly used in the diagnosis and monitoring of many ocular diseases, is an essential part of ophthalmology practice. However, fundus cameras are often costly and rely on separate computers for viewing and transmission of fundus photographs. In addition, adoption of electronic clinical record systems is expected to increase the demand for simple and cost-effective alternatives to the fundus camera that will allow the doctors to capture fundus images themselves during a medical examination. We describe a novel modified technique using slit-lamp biomicroscopy with a noncontact lens, which enables simple and convenient color fundus imaging.
We called our new technique slit lamp- and noncontact lens-assisted photography (SNAP). The technique is basically the same technique as conventional fundus imaging using slit-lamp biomicroscopy with a noncontact lens. However, SNAP images are obtained with a light diffuser on the slit lamp, and the slit lamp oriented at a relatively large angle of approximately 20° to 30° with respect to the optic axis (Fig. 1). SNAP images were captured with a digital single-lens reflex camera (Nikon D300 s, Nikon Imaging Japan Inc., Tokyo, Japan) connected to the slit lamp (RO 5000, Rodenstock, Munich, Germany) and a 90 D lens (Super Field NC lenses, Volk Optical Inc., Mentor, OH, USA).
Color fundus photograph-like fundus images of the retina could be captured not only at the posterior pole but also at the peripheral part using the SNAP technique. The imaging fields of SNAP images were wider than those of basic slit-like fundus images and equivalent to those of color fundus photographs obtained with a conventional fundus camera (Fig. 2). Meanwhile, SNAP images displayed unnecessary reflection in the peripheral image.
Comment
Use of a smartphone for fundus imaging [1–5] demonstrates the appeal of techniques for obtaining fundus images easily and quickly. SNAP, which requires only an ordinary camera, slit lamp, and noncontact lens, is a useful, easy, readily available, and cost-effective technique that enables frequent recording of fundus images in partly digitalized modern clinical practice. Possible future modalities to reduce these reflections include a lens with a coating that reduces reflections from its surface.
References
Maamari RN, Keenan JD, Fletcher DA, Margolis TP (2013) A mobile phone-based retinal camera for portable wide field imaging. Br J Ophthalmology. doi:10.1136/bjophthalmol-2013-303797
Lord RK, Shah VA, San Filippo AN, Krishna R (2010) Novel uses of smartphones in ophthalmology. Ophthalmology 117(6):1274.e3–1274.e1274
Haddock LJ, Kim DY, Mukai S (2013) Simple, inexpensive technique for high-quality smartphone fundus photography in human and animal eyes. J Ophthalmology. doi:10.1155/2013/518479
Chakrabarti R, Perera C (2013) Nonmydriatic digital ocular fundus photography with iPhone 3G. JAMA Ophthalmology 131(3):405–406
Lamirel C, Bruce BB, Wright DW, Newman NJ, Biousse V (2012) Nonmydriatic digital ocular fundus photography on the iPhone 3G: the FOTO-ED study. Arch Ophthalmol 130(7):939–940
Conflicts of interest
No conflicting relationship exists for any author.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.