Abstract
The operation of the primary Coulomb blockade thermometer (CBT) is based on a measurement of the bias-voltage-dependent conductance of arrays of tunnel junctions between normal metal electrodes. Here, a comparison of a CBT with a high-accuracy realization of the PLTS-2000 in the range from 0.008 K to 0.65 K is reported. An overall agreement of about 1 % was found for temperatures above 0.25 K. For lower temperatures, differences increase because the CBT does not reach full thermal equilibrium with its surroundings. This can be accounted for by numerical calculations based on electron–phonon decoupling.
Similar content being viewed by others
References
Preston-Thomas H.: Metrologia 27, 3 (1990)
Procès-Verbaux des Séances du Comité International des Poids et Mesures, BIPM, Sèvres, France, 68, 128 (2001)
Rusby R.L., Durieux M., Reesink A.L., Hudson R.P., Schuster G., Kühne M., Fogle W.E., Soulen R.J., Adams D.E.: J. Low Temp. Phys. 126, 633 (2002)
Giazotto F., Heikkilä T.T., Luukanen A., Savin A., Pekola J.P.: Rev. Mod. Phys. 78, 217 (2006)
Pekola J.P., Hirvi K.P., Kauppinen J.P., Paalanen M.A.: Phys. Rev. Lett. 73, 2903 (1994)
Pekola J.P., Holmqvist T., Meschke M.: Phys. Rev. Lett. 101, 206608 (2008)
Spietz L., Lehnert K.W., Siddiqi I., Schoelkopf R.J.: Science 300, 1929 (2003)
Spietz L., Schoelkopf R.J., Pari P.: Appl. Phys. Lett. 89, 183123 (2006)
Farhangfar Sh., Hirvi K.P., Kauppinen J.P., Pekola J.P., Toppari J.J., Averin D.V., Korotkov A.N.: J. Low Temp. Phys. 108, 191 (1997)
Meschke M., Pekola J.P., Gay F., Rapp R.E., Godfrin H.: J. Low Temp. Phys. 134, 1119 (2004)
Dolan G.J.: Appl. Phys. Lett. 31, 377 (1977)
Rusby R.L., Fellmuth B., Engert J., Fogle W.E., Adams E.D., Pitre L., Durieux M.: J. Low Temp. Phys. 149, 156 (2007)
Engert J., Fellmuth B., Jousten K.: Metrologia 44, 40 (2007)
Zorin A.B.: Rev. Sci. Instrum. 66, 4296 (1995)
Savin A.M., Pekola J.P., Holmqvist T., Hassel J., Grönberg L., Helistö P., Kidiyarova-Shevchenko A.: Appl. Phys. Lett. 99, 084501 (2006)
JCGM 101:2008, “Evaluation of Measurement Data—Supplement 1 to the ‘Guide to the Expression of Uncertainty in Measurement’—Propagation of Distributions using a Monte Carlo Method,” 1st edn. (Joint Committee for Guides in Metrology, BIPM, Sèvres, France, 2008), http://www.bipm.org/en/publications/guides/gum.html
Tsai J.-S., Jain A.K., Lukens J.E.: Phys. Rev. Lett. 51, 316 (1983)
Hamilton C.A.: Rev. Sci. Instrum. 71, 3611 (2000)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Meschke, M., Engert, J., Heyer, D. et al. Comparison of Coulomb Blockade Thermometers with the International Temperature Scale PLTS-2000. Int J Thermophys 32, 1378–1386 (2011). https://doi.org/10.1007/s10765-011-1033-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10765-011-1033-8