The Combined Use of a Gas-Controlled Heat Pipe and a Copper Point to Improve the Calibration of Thermocouples up to 1100 ˚C

  • Published:
International Journal of Thermophysics Aims and scope Submit manuscript

Abstract

The calibration of platinum-based thermocouples from 420 °C to 1,100 ˚C is currently carried out at INRIM making use of two different apparatus: for temperatures below 930 ˚C, a potassium gas-controlled heat pipe (GCHP) is used, whereas a metal-block furnace is adopted for higher temperatures. The standard uncertainty of the reference temperature obtained in the lower temperature range is almost one order of magnitude better than in the higher temperature range. A sealed copper cell was investigated to see if it could be used to calibrate thermocouples above 930 ˚C with a lower uncertainty than our current procedures allowed. The cell was characterized with Type S and Pt/Pd thermocouples and with an HTPRT. The freezing plateaux were flat within 0.01 ˚C and lasted up to 1 h with a repeatability of 0.02 ˚C. The temperature of the cell was determined with a standard uncertainty of 0.04 ˚C. Hence, the copper cell was found to be superior to the comparator furnace for the calibration of platinum-based thermocouples because of the significant decrease in the uncertainty that it provides. An analysis was also carried out on the calibration of Pt/Pd thermocouples, and it was found that the combined use of the potassium GCHP and the Cu fixed-point cell is adequate to exploit the potential of these sensors in the range from 420 °C to 1,084 °C. A comparison with a fixed-point calibration was also made which gave rise to agreement within 0.07 ˚C between the two approaches.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. P. Marcarino, A. Merlone, G. Coggiola, T. Tiziani, in Proceedings of TEMPMEKO ’99, 7th International Symposium on Temperature and Thermal Measurements in Industry and Science, ed. by J.F. Dubbeldam, M.J. de Groot (Edauw Johannissen bv, Delft, 1999), pp. 298–303

  2. P. Marcarino, G. Bonnier, in Proceedings of TEMPMEKO 2004, 9th International Symposium on Temperature and Thermal Measurements in Industry and Science, ed. by D. Zvizdić, L.G. Bermanec, T. Veliki, T. Stašić (FSB/LPM, Zagreb, Croatia, 2004), pp. 33–47

  3. G. Cinato, R. Dematteis, A. Mangano, P. Marcarino, in Proceedings of TEMPMEKO 2001, 8th International Symposium on Temperature and Thermal Measurements in Industry and Science, ed. by B. Fellmuth, J. Seidel, G. Scholz (VDE Verlag, Berlin, 2002), pp. 623–628

  4. Crovini L., Actis A., Galleano R.: High Temp.-High Press. 18, 697 (1987)

    Google Scholar 

  5. P. Marcarino, P.P.M. Steur, R. Dematteis, Report on IMGC measurements for EUROMET Project 624, Rapporto IMGC S/329 (2002)

  6. Astrua M., Battuello M., Girard F.: Meas. Sci. Technol. 17, 2186 (2006)

    Article  ADS  Google Scholar 

  7. ASTM E1751-00 Standard Guide for Temperature Electromotive Force Tables for Non-Letter Designated Thermocouples Combinations (ASTM, West Conshohocken, Pennsylvania, 2000)

  8. F. Edler, M. Albrecht, V. Chimenti, D. del Campo, A. Duke, D. Head, P. Marcarino, P.P.M. Steur, R. Dematteis, M. Megharfi, I. Didialaoui, in Proceedings of TEMPMEKO 2004, 9th International Symposium on Temperature and Thermal Measurements in Industry and Science, ed. by D. Zvizdić, L.G. Bermanec, T. Veliki, T. Stašić (FSB/LPM, Zagreb, Croatia, 2004), pp. 1081–1086.

  9. H. Preston-Thomas, P. Bloembergen, T.J. Quinn, Supplementary Information for the International Temperature Scale of 1990, BIPM (1990)

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Astrua.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Astrua, M., Iacomini, L. & Battuello, M. The Combined Use of a Gas-Controlled Heat Pipe and a Copper Point to Improve the Calibration of Thermocouples up to 1100 ˚C. Int J Thermophys 29, 1838–1847 (2008). https://doi.org/10.1007/s10765-008-0449-2

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10765-008-0449-2

Keywords

Navigation