Skip to main content
Log in

Interlaboratory Comparison of Reference Surface Temperature Apparatus at NMIs

  • Published:
International Journal of Thermophysics Aims and scope Submit manuscript

Abstract

During 2001 and 2002, the first international comparison of surface temperature measurements at national metrology institutes (NMIs) was organized under EUROMET Project No 635. The coordinator for this project was the National Office of Measures (OMH) in Hungary. Among the participants were the Swedish National Testing and Research Institute (SP) from Sweden, the Centre for Metrology and Accreditation (MIKES) in Finland, and Justervesenet (JV) in Norway. The comparison showed a need for better apparatus to reduce the differences in the results from the different laboratories. As a result, a new apparatus was designed at SP and MIKES made some changes to their apparatus. To test the new and modified apparatus, SP took the initiative to arrange and coordinate a new comparison. In this recent comparison, measurements were made at temperatures from 50 to 300°C on surfaces of aluminum and stainless steel. The comparison was arranged and performed during 2005 and 2006. Participants in the comparison were OMH, MIKES, RISOE, JV, and SP. The comparison results using the newly developed apparatus show improved agreement with the earlier EUROMET intercomparison, but also indicate a need for a more standardized calibration method and apparatus to be able to perform calibrations in different laboratories with good agreement.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. E. András, Comparison of reference temperature apparatus at NMIs by comparison of transfer temperature standards. Report EUROMET Project No. 635 (Hungary, 2003)

  2. M. Lidbeck, Comparison of reference temperature apparatus at NMIs by comparison of transfer temperature standards. Technical protocol, rev 2, NICs Project 04164 (Sweden, 2005)

  3. Cox M.G. (2002). Metrologia 39, 591

    Google Scholar 

  4. M. Lidbeck, Comparison of reference temperature apparatus at NMIs by comparison of transfer temperature standards. Report NICs Project 04164 (Sweden, 2006)

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Mats Lidbeck.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lidbeck, M., Ivarsson, J., András, E. et al. Interlaboratory Comparison of Reference Surface Temperature Apparatus at NMIs. Int J Thermophys 29, 414–422 (2008). https://doi.org/10.1007/s10765-007-0303-y

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10765-007-0303-y

Keywords

Navigation